Article: Validation of the Omron HEM-650 wrist blood pressure device using the British Hypertension Society protocol in emergency patients in Hong Kong
Title | Validation of the Omron HEM-650 wrist blood pressure device using the British Hypertension Society protocol in emergency patients in Hong Kong Validación del esfingomanómetro de muñeca Omron HEM-650 utilizando el protocolo de la Sociedad Británica de Hipertensión en pacientes atendidos en un servicio de urgencias de Hong Kong |
---|---|
Authors | |
Keywords | Sphygmomanometer Blood pressure Oscillometric Wrist device Validation |
Issue Date | 2015 |
Publisher | Grupo Saned. The Journal's web site is located at http://emergencias.portalsemes.org/ |
Citation | Emergencias, 2015, v. 27, n. 5, p. 313-315 How to Cite? |
Abstract | Aims. Automated wrist cuff blood pressure (BP) devices are more compact and easier to use, particularly when access to the upper arm is restricted, for example in emergencies. Methods. We tested the Omron HEM-650 wrist device using the validation criteria of the British Hypertension Society (BHS) protocol in a major emergency department (ED) in Hong Kong. 85 patients had three measurements each by both the Omron HEM-650 wrist device and the mercury sphygmomanometer. The conventional automated BP with arm cuff was also measured using an oscillometric (Colin BP-88S NXT) device for comparison. Results. The Omron HEM-650 achieved a grade B for both systolic and diastolic BP and demonstrated acceptable accuracy and reliability in Chinese patients in the emergency setting. Conclusions. The Omron HEM 650 wrist device can be recommended for use in adult emergency patients. Further research is warranted for its use in pregnant women and critically ill patients. |
Persistent Identifier | http://hdl.handle.net/10722/292240 |
ISSN | 2023 Impact Factor: 5.4 2023 SCImago Journal Rankings: 0.589 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hung, Kevin K.C. | - |
dc.contributor.author | Lai, W. Y. | - |
dc.contributor.author | Cocks, Robert A. | - |
dc.contributor.author | Rainer, Timothy H. | - |
dc.contributor.author | Graham, Colin A. | - |
dc.date.accessioned | 2020-11-17T14:56:03Z | - |
dc.date.available | 2020-11-17T14:56:03Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Emergencias, 2015, v. 27, n. 5, p. 313-315 | - |
dc.identifier.issn | 1137-6821 | - |
dc.identifier.uri | http://hdl.handle.net/10722/292240 | - |
dc.description.abstract | Aims. Automated wrist cuff blood pressure (BP) devices are more compact and easier to use, particularly when access to the upper arm is restricted, for example in emergencies. Methods. We tested the Omron HEM-650 wrist device using the validation criteria of the British Hypertension Society (BHS) protocol in a major emergency department (ED) in Hong Kong. 85 patients had three measurements each by both the Omron HEM-650 wrist device and the mercury sphygmomanometer. The conventional automated BP with arm cuff was also measured using an oscillometric (Colin BP-88S NXT) device for comparison. Results. The Omron HEM-650 achieved a grade B for both systolic and diastolic BP and demonstrated acceptable accuracy and reliability in Chinese patients in the emergency setting. Conclusions. The Omron HEM 650 wrist device can be recommended for use in adult emergency patients. Further research is warranted for its use in pregnant women and critically ill patients. | - |
dc.language | eng | - |
dc.publisher | Grupo Saned. The Journal's web site is located at http://emergencias.portalsemes.org/ | - |
dc.relation.ispartof | Emergencias | - |
dc.subject | Sphygmomanometer | - |
dc.subject | Blood pressure | - |
dc.subject | Oscillometric | - |
dc.subject | Wrist device | - |
dc.subject | Validation | - |
dc.title | Validation of the Omron HEM-650 wrist blood pressure device using the British Hypertension Society protocol in emergency patients in Hong Kong | - |
dc.title | Validación del esfingomanómetro de muñeca Omron HEM-650 utilizando el protocolo de la Sociedad Británica de Hipertensión en pacientes atendidos en un servicio de urgencias de Hong Kong | - |
dc.type | Article | - |
dc.description.nature | link_to_OA_fulltext | - |
dc.identifier.pmid | 29087056 | - |
dc.identifier.scopus | eid_2-s2.0-84943153159 | - |
dc.identifier.volume | 27 | - |
dc.identifier.issue | 5 | - |
dc.identifier.spage | 313 | - |
dc.identifier.epage | 315 | - |
dc.identifier.isi | WOS:000362614000007 | - |
dc.identifier.issnl | 1137-6821 | - |