Article: Patient motion image artifacts can be minimized and re-exposure avoided by selective removal of a sequence of basis images from cone beam computed tomography data sets: a case series

TitlePatient motion image artifacts can be minimized and re-exposure avoided by selective removal of a sequence of basis images from cone beam computed tomography data sets: a case series
Authors
Keywordsadult
case study
clinical article
cone beam computed tomography
female
Issue Date2020
PublisherElsevier BV. The Journal's web site is located at http://www.oooojournal.net
Citation
Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2020, v. 129 n. 2, p. e212-e223 How to Cite?
AbstractThis case series describes a reconstruction method applied to a cone beam computed tomography (CBCT) projection data set that used selected basis projection images to improve diagnostic image quality for patients who moved during the radiographic procedure. Reconstructed volumetric data from 6 patients at 2 institutions initially exhibited characteristic double contour images as a result of motion artifacts. For each case, the CBCT basis images from the entire projection data set were displayed as a cine sequence, and patient movement was identified during the first or last 90-degrees of a full 360-degree acquisition trajectory. Employing a useful reconstruction function of proprietary software, a secondary reconstruction was performed by discarding data acquired during the first and last 90-degree rotation. For all cases, this method provided a volumetric data set without motion artifact. General practitioners can apply this clinical method, whenever appropriate, to avoid a rescan and keep patient exposure “as low as diagnostically acceptable.”
Persistent Identifierhttp://hdl.handle.net/10722/280356
ISSN
2023 Impact Factor: 2.0
2023 SCImago Journal Rankings: 0.557
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorYeung, AWK-
dc.contributor.authorAzevedo, B-
dc.contributor.authorScarfe, WC-
dc.contributor.authorBornstein, MM-
dc.date.accessioned2020-02-07T07:39:55Z-
dc.date.available2020-02-07T07:39:55Z-
dc.date.issued2020-
dc.identifier.citationOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2020, v. 129 n. 2, p. e212-e223-
dc.identifier.issn2212-4403-
dc.identifier.urihttp://hdl.handle.net/10722/280356-
dc.description.abstractThis case series describes a reconstruction method applied to a cone beam computed tomography (CBCT) projection data set that used selected basis projection images to improve diagnostic image quality for patients who moved during the radiographic procedure. Reconstructed volumetric data from 6 patients at 2 institutions initially exhibited characteristic double contour images as a result of motion artifacts. For each case, the CBCT basis images from the entire projection data set were displayed as a cine sequence, and patient movement was identified during the first or last 90-degrees of a full 360-degree acquisition trajectory. Employing a useful reconstruction function of proprietary software, a secondary reconstruction was performed by discarding data acquired during the first and last 90-degree rotation. For all cases, this method provided a volumetric data set without motion artifact. General practitioners can apply this clinical method, whenever appropriate, to avoid a rescan and keep patient exposure “as low as diagnostically acceptable.”-
dc.languageeng-
dc.publisherElsevier BV. The Journal's web site is located at http://www.oooojournal.net-
dc.relation.ispartofOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology-
dc.subjectadult-
dc.subjectcase study-
dc.subjectclinical article-
dc.subjectcone beam computed tomography-
dc.subjectfemale-
dc.titlePatient motion image artifacts can be minimized and re-exposure avoided by selective removal of a sequence of basis images from cone beam computed tomography data sets: a case series-
dc.typeArticle-
dc.identifier.emailYeung, AWK: ndyeung@hku.hk-
dc.identifier.emailBornstein, MM: bornst@hku.hk-
dc.identifier.authorityYeung, AWK=rp02143-
dc.identifier.authorityBornstein, MM=rp02217-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.oooo.2019.07.003-
dc.identifier.pmid31416715-
dc.identifier.scopuseid_2-s2.0-85070382311-
dc.identifier.hkuros309096-
dc.identifier.volume129-
dc.identifier.issue2-
dc.identifier.spagee212-
dc.identifier.epagee223-
dc.identifier.isiWOS:000509764400003-
dc.publisher.placeNetherlands-
dc.identifier.issnl2212-4403-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats