File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Improved residue function and reduced flow dependence in MR perfusion using least-absolute-deviation regularization

TitleImproved residue function and reduced flow dependence in MR perfusion using least-absolute-deviation regularization
Authors
KeywordsLeast absolute deviation
Bolus delay
LAD
Quantitative perfusion analysis
Mr perfusion
Issue Date2009
Citation
Magnetic Resonance in Medicine, 2009, v. 61, n. 2, p. 418-428 How to Cite?
AbstractCerebral blood flow (CBF) estimates derived from singular value decomposition (SVD) of time intensity curves from Gadolinium bolus perfusion-weighted imaging are known to underestimate CBF, especially at high flow rates. We report the development of a model-independent delay-invariant deconvolution technique using least-absolute-deviation (LAD) regularization to improve the CBF estimation accuracy. Computer simulations were performed to compare the accuracy of CBF estimates derived from LAD, reformulated SVD (rSVD) and standard SVD (sSVD) techniques. Simulations were performed at image signal-to-noise ratios ranging from 20 to 400, cerebral blood volumes from 1% to 10%, and CBF from 2.5 mL/100 g/min to 176.5 mL/100 g/min to estimate the effect of these parameters on the accuracy of CBF estimation. The LAD method improved the CBF estimation accuracy by up to 32% in gray matter and 23% in white matter compared with rSVD and sSVD methods. LAD method also reduces the systematic bias of rSVD and sSVD methods to baseline SNR while producing more accurate and reproducible residue function calculation than either rSVD or sSVD method. Initial clinical implementation of the method on six representative clinical cases confirm the advantages of the LAD method over rSVD and sSVD methods. © 2009 Wiley-Liss, Inc.
Persistent Identifierhttp://hdl.handle.net/10722/276836
ISSN
2023 Impact Factor: 3.0
2023 SCImago Journal Rankings: 1.343
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorWong, Kelvin K.-
dc.contributor.authorTam, Chi Pan-
dc.contributor.authorNg, Michael-
dc.contributor.authorWong, Stephen T.C.-
dc.contributor.authorYoung, Geoffrey S.-
dc.date.accessioned2019-09-18T08:34:48Z-
dc.date.available2019-09-18T08:34:48Z-
dc.date.issued2009-
dc.identifier.citationMagnetic Resonance in Medicine, 2009, v. 61, n. 2, p. 418-428-
dc.identifier.issn0740-3194-
dc.identifier.urihttp://hdl.handle.net/10722/276836-
dc.description.abstractCerebral blood flow (CBF) estimates derived from singular value decomposition (SVD) of time intensity curves from Gadolinium bolus perfusion-weighted imaging are known to underestimate CBF, especially at high flow rates. We report the development of a model-independent delay-invariant deconvolution technique using least-absolute-deviation (LAD) regularization to improve the CBF estimation accuracy. Computer simulations were performed to compare the accuracy of CBF estimates derived from LAD, reformulated SVD (rSVD) and standard SVD (sSVD) techniques. Simulations were performed at image signal-to-noise ratios ranging from 20 to 400, cerebral blood volumes from 1% to 10%, and CBF from 2.5 mL/100 g/min to 176.5 mL/100 g/min to estimate the effect of these parameters on the accuracy of CBF estimation. The LAD method improved the CBF estimation accuracy by up to 32% in gray matter and 23% in white matter compared with rSVD and sSVD methods. LAD method also reduces the systematic bias of rSVD and sSVD methods to baseline SNR while producing more accurate and reproducible residue function calculation than either rSVD or sSVD method. Initial clinical implementation of the method on six representative clinical cases confirm the advantages of the LAD method over rSVD and sSVD methods. © 2009 Wiley-Liss, Inc.-
dc.languageeng-
dc.relation.ispartofMagnetic Resonance in Medicine-
dc.subjectLeast absolute deviation-
dc.subjectBolus delay-
dc.subjectLAD-
dc.subjectQuantitative perfusion analysis-
dc.subjectMr perfusion-
dc.titleImproved residue function and reduced flow dependence in MR perfusion using least-absolute-deviation regularization-
dc.typeArticle-
dc.description.naturelink_to_OA_fulltext-
dc.identifier.doi10.1002/mrm.21860-
dc.identifier.pmid19161133-
dc.identifier.scopuseid_2-s2.0-60549114731-
dc.identifier.volume61-
dc.identifier.issue2-
dc.identifier.spage418-
dc.identifier.epage428-
dc.identifier.eissn1522-2594-
dc.identifier.isiWOS:000262871300020-
dc.identifier.issnl0740-3194-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats