File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Combining physical and biologic parameters to predict radiation-induced lung toxicity in patients with non-small-cell lung cancer treated with definitive radiation therapy

TitleCombining physical and biologic parameters to predict radiation-induced lung toxicity in patients with non-small-cell lung cancer treated with definitive radiation therapy
Authors
Issue Date2012
Citation
International Journal of Radiation Oncology Biology Physics, 2012, v. 84, n. 2 How to Cite?
AbstractPurpose: To investigate the plasma dynamics of 5 proinflammatory/fibrogenic cytokines, including interleukin-1beta (IL-1β), IL-6, IL-8, tumor necrosis factor alpha (TNF-α), and transforming growth factor beta1 (TGF-β1) to ascertain their value in predicting radiation-induced lung toxicity (RILT), both individually and in combination with physical dosimetric parameters. Methods and Materials: Treatments of patients receiving definitive conventionally fractionated radiation therapy (RT) on clinical trial for inoperable stages I-III lung cancer were prospectively evaluated. Circulating cytokine levels were measured prior to and at weeks 2 and 4 during RT. The primary endpoint was symptomatic RILT, defined as grade 2 and higher radiation pneumonitis or symptomatic pulmonary fibrosis. Minimum follow-up was 18 months. Results: Of 58 eligible patients, 10 (17.2%) patients developed RILT. Lower pretreatment IL-8 levels were significantly correlated with development of RILT, while radiation-induced elevations of TGF-ß1 were weakly correlated with RILT. Significant correlations were not found for any of the remaining 3 cytokines or for any clinical or dosimetric parameters. Using receiver operator characteristic curves for predictive risk assessment modeling, we found both individual cytokines and dosimetric parameters were poor independent predictors of RILT. However, combining IL-8, TGF-ß1, and mean lung dose into a single model yielded an improved predictive ability (P<.001) compared to either variable alone. Conclusions: Combining inflammatory cytokines with physical dosimetric factors may provide a more accurate model for RILT prediction. Future study with a larger number of cases and events is needed to validate such findings. © 2012 Elsevier Inc.
Persistent Identifierhttp://hdl.handle.net/10722/266939
ISSN
2021 Impact Factor: 8.013
2020 SCImago Journal Rankings: 2.117
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorStenmark, Matthew H.-
dc.contributor.authorCai, Xu Wei-
dc.contributor.authorShedden, Kerby-
dc.contributor.authorHayman, James A.-
dc.contributor.authorYuan, Shuanghu-
dc.contributor.authorRitter, Timothy-
dc.contributor.authorTen Haken, Randall K.-
dc.contributor.authorLawrence, Theodore S.-
dc.contributor.authorKong, Feng Ming-
dc.date.accessioned2019-01-31T07:20:02Z-
dc.date.available2019-01-31T07:20:02Z-
dc.date.issued2012-
dc.identifier.citationInternational Journal of Radiation Oncology Biology Physics, 2012, v. 84, n. 2-
dc.identifier.issn0360-3016-
dc.identifier.urihttp://hdl.handle.net/10722/266939-
dc.description.abstractPurpose: To investigate the plasma dynamics of 5 proinflammatory/fibrogenic cytokines, including interleukin-1beta (IL-1β), IL-6, IL-8, tumor necrosis factor alpha (TNF-α), and transforming growth factor beta1 (TGF-β1) to ascertain their value in predicting radiation-induced lung toxicity (RILT), both individually and in combination with physical dosimetric parameters. Methods and Materials: Treatments of patients receiving definitive conventionally fractionated radiation therapy (RT) on clinical trial for inoperable stages I-III lung cancer were prospectively evaluated. Circulating cytokine levels were measured prior to and at weeks 2 and 4 during RT. The primary endpoint was symptomatic RILT, defined as grade 2 and higher radiation pneumonitis or symptomatic pulmonary fibrosis. Minimum follow-up was 18 months. Results: Of 58 eligible patients, 10 (17.2%) patients developed RILT. Lower pretreatment IL-8 levels were significantly correlated with development of RILT, while radiation-induced elevations of TGF-ß1 were weakly correlated with RILT. Significant correlations were not found for any of the remaining 3 cytokines or for any clinical or dosimetric parameters. Using receiver operator characteristic curves for predictive risk assessment modeling, we found both individual cytokines and dosimetric parameters were poor independent predictors of RILT. However, combining IL-8, TGF-ß1, and mean lung dose into a single model yielded an improved predictive ability (P<.001) compared to either variable alone. Conclusions: Combining inflammatory cytokines with physical dosimetric factors may provide a more accurate model for RILT prediction. Future study with a larger number of cases and events is needed to validate such findings. © 2012 Elsevier Inc.-
dc.languageeng-
dc.relation.ispartofInternational Journal of Radiation Oncology Biology Physics-
dc.titleCombining physical and biologic parameters to predict radiation-induced lung toxicity in patients with non-small-cell lung cancer treated with definitive radiation therapy-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.ijrobp.2012.03.067-
dc.identifier.pmid22935395-
dc.identifier.scopuseid_2-s2.0-84865614901-
dc.identifier.volume84-
dc.identifier.issue2-
dc.identifier.spagenull-
dc.identifier.epagenull-
dc.identifier.eissn1879-355X-
dc.identifier.isiWOS:000308062700013-
dc.identifier.issnl0360-3016-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats