File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Article: Design and test of the fluid separation detection system
Title | Design and test of the fluid separation detection system |
---|---|
Authors | |
Keywords | Separation Sensor array Metrology Boundary layer Wind tunnel test |
Issue Date | 2008 |
Citation | Jiliang Xuebao/Acta Metrologica Sinica, 2008, v. 29, n. 1, p. 46-50 How to Cite? |
Abstract | At the fluid boundary layer separation point, the mean shear stress drops to small value while its fluctuation increases dramatically. The design and fabrication method of the micro thermal shear stress sensor array, the methods of bias and filter circuits, and integrated the array on the NACA0012 typical aerofoil are presented. Through testing in low speed wind tunnel, the position of the fluid separation can be detected accurately and effectively. |
Persistent Identifier | http://hdl.handle.net/10722/265533 |
ISSN | 2023 SCImago Journal Rankings: 0.233 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Liu, Kui | - |
dc.contributor.author | Yuan, Wei Zheng | - |
dc.contributor.author | Deng, Jin Jun | - |
dc.contributor.author | Ma, Bing He | - |
dc.contributor.author | Jiang, Cheng Yu | - |
dc.date.accessioned | 2018-12-03T01:20:57Z | - |
dc.date.available | 2018-12-03T01:20:57Z | - |
dc.date.issued | 2008 | - |
dc.identifier.citation | Jiliang Xuebao/Acta Metrologica Sinica, 2008, v. 29, n. 1, p. 46-50 | - |
dc.identifier.issn | 1000-1158 | - |
dc.identifier.uri | http://hdl.handle.net/10722/265533 | - |
dc.description.abstract | At the fluid boundary layer separation point, the mean shear stress drops to small value while its fluctuation increases dramatically. The design and fabrication method of the micro thermal shear stress sensor array, the methods of bias and filter circuits, and integrated the array on the NACA0012 typical aerofoil are presented. Through testing in low speed wind tunnel, the position of the fluid separation can be detected accurately and effectively. | - |
dc.language | eng | - |
dc.relation.ispartof | Jiliang Xuebao/Acta Metrologica Sinica | - |
dc.subject | Separation | - |
dc.subject | Sensor array | - |
dc.subject | Metrology | - |
dc.subject | Boundary layer | - |
dc.subject | Wind tunnel test | - |
dc.title | Design and test of the fluid separation detection system | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.scopus | eid_2-s2.0-39749159826 | - |
dc.identifier.volume | 29 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 46 | - |
dc.identifier.epage | 50 | - |
dc.identifier.issnl | 1000-1158 | - |