File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1063/1.1591083
- Scopus: eid_2-s2.0-0041339634
- WOS: WOS:000183877800068
- Find via

Supplementary
- Citations:
- Appears in Collections:
Article: Terahertz plasmonic high pass filter
| Title | Terahertz plasmonic high pass filter |
|---|---|
| Authors | |
| Issue Date | 2003 |
| Publisher | American Institute of Physics. The Journal's web site is located at http://apl.aip.org/ |
| Citation | Applied Physics Letters, 2003, v. 83 n. 1, p. 201-203 How to Cite? |
| Abstract | Terahertz plasmonic high pass filter was studied. The sharp change of reflection and transmission of electromagnetic waves at plasma frequency made the structure a high pass filter. Fourier transform infrared spectroscopy was used to characterize the reflection response, and a plasma frequency at 0.7 THz was observed. |
| Persistent Identifier | http://hdl.handle.net/10722/256877 |
| ISSN | 2023 Impact Factor: 3.5 2023 SCImago Journal Rankings: 0.976 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Wu, Dongmin | - |
| dc.contributor.author | Fang, Nicholas | - |
| dc.contributor.author | Sun, Cheng | - |
| dc.contributor.author | Zhang, Xiang | - |
| dc.contributor.author | Padilla, Willie J. | - |
| dc.contributor.author | Basov, Dimitri N. | - |
| dc.contributor.author | Smith, David R. | - |
| dc.contributor.author | Schultz, Sheldon | - |
| dc.date.accessioned | 2018-07-24T08:58:12Z | - |
| dc.date.available | 2018-07-24T08:58:12Z | - |
| dc.date.issued | 2003 | - |
| dc.identifier.citation | Applied Physics Letters, 2003, v. 83 n. 1, p. 201-203 | - |
| dc.identifier.issn | 0003-6951 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/256877 | - |
| dc.description.abstract | Terahertz plasmonic high pass filter was studied. The sharp change of reflection and transmission of electromagnetic waves at plasma frequency made the structure a high pass filter. Fourier transform infrared spectroscopy was used to characterize the reflection response, and a plasma frequency at 0.7 THz was observed. | - |
| dc.language | eng | - |
| dc.publisher | American Institute of Physics. The Journal's web site is located at http://apl.aip.org/ | - |
| dc.relation.ispartof | Applied Physics Letters | - |
| dc.title | Terahertz plasmonic high pass filter | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.1063/1.1591083 | - |
| dc.identifier.scopus | eid_2-s2.0-0041339634 | - |
| dc.identifier.volume | 83 | - |
| dc.identifier.issue | 1 | - |
| dc.identifier.spage | 201 | - |
| dc.identifier.epage | 203 | - |
| dc.identifier.isi | WOS:000183877800068 | - |
| dc.identifier.issnl | 0003-6951 | - |
