Conference Paper: On detachment of micron droplets using a centrifugal method

TitleOn detachment of micron droplets using a centrifugal method
Authors
Issue Date2013
Citation
American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM, 2013, v. 1C, article no. V01CT17A002 How to Cite?
AbstractLiquid drops adhering to and dislodging from solid surfaces are of common occurrence in a diverse range of industrial and environmental processes. Although tremendous effort, both experimental and theoretical, has been spent on studying the fundamental mechanisms of particle resuspension, most studies concentrated on solid particles. The detachment behaviour of drops is different from that of solid particles; drops may deform and split into smaller portions during detachment and those studies are lacking in literature, especially for small droplets (in the range of micron size). This paper studies the detachment of a droplet from a plastic substrate by a centrifugal method. Monodisperse glycerol droplets in the sizes of micron ranges were generated and deposited on the substrate. Owing to the small in size, an ultracentrifuge was employed to generate the removal forces, in both normal and tangential directions. The detachment behaviours were found different in different force directions. For the normal direction, larger droplets split into smaller portions during detachment; some portions are detached and the remains form smaller droplets on the substrate. The volume fraction that remained or detached against the removal forces was determined and the result was compared with that of the solid particle. For the tangential direction, the droplet is stationary until a high enough force field is applied at which the whole droplet is detached. The phenomena are explained by the retention force model which was previously employed in a larger drop and this research shows that the same model is potential to be applicable to a small droplet in micron size. Copyright © 2013 by ASME.
Persistent Identifierhttp://hdl.handle.net/10722/256023
ISSN
2020 SCImago Journal Rankings: 0.144
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorFu, S. C.-
dc.contributor.authorLeung, W. T.-
dc.contributor.authorChao, C. Y.H.-
dc.date.accessioned2018-07-16T06:14:22Z-
dc.date.available2018-07-16T06:14:22Z-
dc.date.issued2013-
dc.identifier.citationAmerican Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM, 2013, v. 1C, article no. V01CT17A002-
dc.identifier.issn0888-8116-
dc.identifier.urihttp://hdl.handle.net/10722/256023-
dc.description.abstractLiquid drops adhering to and dislodging from solid surfaces are of common occurrence in a diverse range of industrial and environmental processes. Although tremendous effort, both experimental and theoretical, has been spent on studying the fundamental mechanisms of particle resuspension, most studies concentrated on solid particles. The detachment behaviour of drops is different from that of solid particles; drops may deform and split into smaller portions during detachment and those studies are lacking in literature, especially for small droplets (in the range of micron size). This paper studies the detachment of a droplet from a plastic substrate by a centrifugal method. Monodisperse glycerol droplets in the sizes of micron ranges were generated and deposited on the substrate. Owing to the small in size, an ultracentrifuge was employed to generate the removal forces, in both normal and tangential directions. The detachment behaviours were found different in different force directions. For the normal direction, larger droplets split into smaller portions during detachment; some portions are detached and the remains form smaller droplets on the substrate. The volume fraction that remained or detached against the removal forces was determined and the result was compared with that of the solid particle. For the tangential direction, the droplet is stationary until a high enough force field is applied at which the whole droplet is detached. The phenomena are explained by the retention force model which was previously employed in a larger drop and this research shows that the same model is potential to be applicable to a small droplet in micron size. Copyright © 2013 by ASME.-
dc.languageeng-
dc.relation.ispartofAmerican Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM-
dc.titleOn detachment of micron droplets using a centrifugal method-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1115/FEDSM2013-16084-
dc.identifier.scopuseid_2-s2.0-84892992692-
dc.identifier.volume1C-
dc.identifier.spagearticle no. V01CT17A002-
dc.identifier.epagearticle no. V01CT17A002-
dc.identifier.isiWOS:000359030900002-
dc.identifier.issnl0888-8116-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats