Article: A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach
Title | A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach |
---|---|
Authors | |
Keywords | Dispersion Airborne transmission Unidirectional airflow Infectious diseases Expiratory aerosols Ceiling-return airflow |
Issue Date | 2006 |
Citation | Indoor Air, 2006, v. 16, n. 4, p. 296-312 How to Cite? |
Abstract | Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experiments employing optical techniques were conducted in a chamber with downward airflow pattern to measure the dispersion of aerosols. Some of the numerical results were compared with the chamber measurement results. Reasonable agreement was found. Small aerosols (initial size ≤ 45 μm) had settling times of below 20 s in downward flow but increased to 32-80 s in ceiling-return flow. Lateral dispersion was limited to around 0.3 m in downward flow, in which only turbulent dispersion was significant. It increased to over 2 m in ceiling-return flow, which had a combination of both turbulant dispersion and bulk flow transport mechanisms. The significance of aerosol transport by bulk flow was about an order of magnitude stronger than that by turbulent dispersion. However, results also show that aerosols could be dispersed for considerable distances solely by turbulence if they were suspended longer. Large aerosols settled within very short time due to heavy gravitational effects. The results provided new insights in designing proper bed spacing in hospital ward environments. © Indoor Air (2006). |
Persistent Identifier | http://hdl.handle.net/10722/255871 |
ISSN | 2023 Impact Factor: 4.3 2023 SCImago Journal Rankings: 0.997 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chao, C. Y.H. | - |
dc.contributor.author | Wan, M. P. | - |
dc.date.accessioned | 2018-07-16T06:13:55Z | - |
dc.date.available | 2018-07-16T06:13:55Z | - |
dc.date.issued | 2006 | - |
dc.identifier.citation | Indoor Air, 2006, v. 16, n. 4, p. 296-312 | - |
dc.identifier.issn | 0905-6947 | - |
dc.identifier.uri | http://hdl.handle.net/10722/255871 | - |
dc.description.abstract | Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experiments employing optical techniques were conducted in a chamber with downward airflow pattern to measure the dispersion of aerosols. Some of the numerical results were compared with the chamber measurement results. Reasonable agreement was found. Small aerosols (initial size ≤ 45 μm) had settling times of below 20 s in downward flow but increased to 32-80 s in ceiling-return flow. Lateral dispersion was limited to around 0.3 m in downward flow, in which only turbulent dispersion was significant. It increased to over 2 m in ceiling-return flow, which had a combination of both turbulant dispersion and bulk flow transport mechanisms. The significance of aerosol transport by bulk flow was about an order of magnitude stronger than that by turbulent dispersion. However, results also show that aerosols could be dispersed for considerable distances solely by turbulence if they were suspended longer. Large aerosols settled within very short time due to heavy gravitational effects. The results provided new insights in designing proper bed spacing in hospital ward environments. © Indoor Air (2006). | - |
dc.language | eng | - |
dc.relation.ispartof | Indoor Air | - |
dc.subject | Dispersion | - |
dc.subject | Airborne transmission | - |
dc.subject | Unidirectional airflow | - |
dc.subject | Infectious diseases | - |
dc.subject | Expiratory aerosols | - |
dc.subject | Ceiling-return airflow | - |
dc.title | A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1111/j.1600-0668.2006.00426.x | - |
dc.identifier.pmid | 16842610 | - |
dc.identifier.scopus | eid_2-s2.0-33745698432 | - |
dc.identifier.volume | 16 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 296 | - |
dc.identifier.epage | 312 | - |
dc.identifier.eissn | 1600-0668 | - |
dc.identifier.isi | WOS:000238754700005 | - |
dc.identifier.issnl | 0905-6947 | - |