Article: Three-dimensional Frankfort horizontal plane for 3D cephalometry: a comparative assessment of conventional versus novel landmarks and horizontal planes

TitleThree-dimensional Frankfort horizontal plane for 3D cephalometry: a comparative assessment of conventional versus novel landmarks and horizontal planes
Authors
Keywordsframingham heart study
cephalometry
maxilla
cranium
software
Issue Date2018
PublisherOxford University Press. The Journal's web site is located at http://ejo.oxfordjournals.org/
Citation
European Journal of Orthodontics, 2018, v. 40 n. 3, p. 239-248 How to Cite?
AbstractBackground: To assess the reproducibility of landmarks in three dimensions that determine the Frankfort horizontal plane (FH) as well as two new landmarks, and to evaluate the angular differences of newly introduced planes to the FH. Methods: Three-dimensional (3D) surface models were created from CBCT scans of 26 dry human skulls. Porion (Po), orbitale (Or), internal acoustic foramen (IAF), and zygomatico-maxillary suture (ZyMS) were indicated in the software by three observers twice with a 4-week interval. Angles between two FHs (FH 1: Or-R, Or-L, mid-Po; FH 2: Po-R, Po-L, mid-Or) and between FHs and new planes (Plane 1–6) were measured. Coordinates were exported to a spreadsheet. A statistical analysis was performed to define the landmark reproducibility and 3D angles. Results: Intra- and inter-observer landmark reproducibility showed mean difference more than 1 mm for x-coordinates of all landmarks except IAF. IAF showed significantly better reproducibility than other landmarks (P < 0.0018). The mean angular difference between FH 1 and FH 2 was 0.7 degrees. Plane 3, connecting Or-R, Or-L and mid-IAF, and Plane 4, connecting Po-R, Po-L and mid-ZyMS, both showed an angular difference of less than 1 degree when compared to FHs. Conclusions: This study revealed poor reproducibility of the traditional FH landmarks on the x-axis and good reproducibility of a new landmark tested to replace Po, the IAF. Yet, Or showed superior results compared to ZyMS. The potential of using new horizontal planes was demonstrated. Future studies should focus on identification of a valid alternative for Or and ZyMS and on clinical implementation of the findings.
Persistent Identifierhttp://hdl.handle.net/10722/247246
ISSN
2023 Impact Factor: 2.8
2023 SCImago Journal Rankings: 0.940
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorPittayapat, P-
dc.contributor.authorJacobs, R-
dc.contributor.authorBornstein, MM-
dc.contributor.authorOdri, GA-
dc.contributor.authorLambrichts, I-
dc.contributor.authorWillems, G-
dc.contributor.authorPolitis, C-
dc.contributor.authorOlszewski, R-
dc.date.accessioned2017-10-18T08:24:29Z-
dc.date.available2017-10-18T08:24:29Z-
dc.date.issued2018-
dc.identifier.citationEuropean Journal of Orthodontics, 2018, v. 40 n. 3, p. 239-248-
dc.identifier.issn0141-5387-
dc.identifier.urihttp://hdl.handle.net/10722/247246-
dc.description.abstractBackground: To assess the reproducibility of landmarks in three dimensions that determine the Frankfort horizontal plane (FH) as well as two new landmarks, and to evaluate the angular differences of newly introduced planes to the FH. Methods: Three-dimensional (3D) surface models were created from CBCT scans of 26 dry human skulls. Porion (Po), orbitale (Or), internal acoustic foramen (IAF), and zygomatico-maxillary suture (ZyMS) were indicated in the software by three observers twice with a 4-week interval. Angles between two FHs (FH 1: Or-R, Or-L, mid-Po; FH 2: Po-R, Po-L, mid-Or) and between FHs and new planes (Plane 1–6) were measured. Coordinates were exported to a spreadsheet. A statistical analysis was performed to define the landmark reproducibility and 3D angles. Results: Intra- and inter-observer landmark reproducibility showed mean difference more than 1 mm for x-coordinates of all landmarks except IAF. IAF showed significantly better reproducibility than other landmarks (P < 0.0018). The mean angular difference between FH 1 and FH 2 was 0.7 degrees. Plane 3, connecting Or-R, Or-L and mid-IAF, and Plane 4, connecting Po-R, Po-L and mid-ZyMS, both showed an angular difference of less than 1 degree when compared to FHs. Conclusions: This study revealed poor reproducibility of the traditional FH landmarks on the x-axis and good reproducibility of a new landmark tested to replace Po, the IAF. Yet, Or showed superior results compared to ZyMS. The potential of using new horizontal planes was demonstrated. Future studies should focus on identification of a valid alternative for Or and ZyMS and on clinical implementation of the findings.-
dc.languageeng-
dc.publisherOxford University Press. The Journal's web site is located at http://ejo.oxfordjournals.org/-
dc.relation.ispartofEuropean Journal of Orthodontics-
dc.rightsPre-print: Journal Title] ©: [year] [owner as specified on the article] Published by Oxford University Press [on behalf of xxxxxx]. All rights reserved. Pre-print (Once an article is published, preprint notice should be amended to): This is an electronic version of an article published in [include the complete citation information for the final version of the Article as published in the print edition of the Journal.] Post-print: This is a pre-copy-editing, author-produced PDF of an article accepted for publication in [insert journal title] following peer review. The definitive publisher-authenticated version [insert complete citation information here] is available online at: xxxxxxx [insert URL that the author will receive upon publication here].-
dc.subjectframingham heart study-
dc.subjectcephalometry-
dc.subjectmaxilla-
dc.subjectcranium-
dc.subjectsoftware-
dc.titleThree-dimensional Frankfort horizontal plane for 3D cephalometry: a comparative assessment of conventional versus novel landmarks and horizontal planes-
dc.typeArticle-
dc.identifier.emailBornstein, MM: bornst@hku.hk-
dc.identifier.authorityBornstein, MM=rp02217-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1093/ejo/cjx066-
dc.identifier.pmid29016738-
dc.identifier.scopuseid_2-s2.0-85047729577-
dc.identifier.hkuros281875-
dc.identifier.volume40-
dc.identifier.issue3-
dc.identifier.spage239-
dc.identifier.epage248-
dc.identifier.isiWOS:000434154900002-
dc.publisher.placeUnited Kingdom-
dc.identifier.issnl0141-5387-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats