File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Using color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position

TitleUsing color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position
Authors
KeywordsSensitivity
Nasogastric tube
Air insufflation
Color Doppler
Ultrasound
Specificity
Issue Date2017
Citation
American Journal of Emergency Medicine, 2017, v. 35, n. 2, p. 333-336 How to Cite?
Abstract© 2016 Elsevier Inc.Objectives Previous studies have shown that ultrasonography (USG), as an alternative to radiography, has a good accuracy in confirming nasogastric tube (NGT) position. Color flow detection of air insufflation is a novel approach in verifying NGT position. In our study, we aimed at evaluating its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in confirming the NGT position, as compared with 2-dimensional (2D) USG. Methods The study was conducted on adult patients over a period of 38 months in an emergency department in Hong Kong. 2D USG and color flow Doppler imaging were conducted for each subject. Chest X-ray was used as the gold standard for NGT position confirmation. Results 100 patients (59 males and 41 females) were recruited totally. Their mean age was 82. The sensitivity, specificity, PPV and NPV of 2D USG were 11.1% (95% CI 4.6%–17.6%), 100% (95% CI 100%–100%), 100% (95% CI 100%–100%), and 11.1% (95% CI 4.6%–17.6%) respectively. For color flow Doppler USG, the sensitivity, specificity, PPV and NPV were 90% (95% CI 83.7%–96.2%), 80% (95% CI 55.2%–100%), 97.6% (95% CI 94.3%–100%), and 47.1% (95% CI 23.3%–70.8%) respectively. The overall accuracy of color Doppler imaging was 89%, which was higher than that of 2D USG (20% only). Conclusions Color flow detection of air insufflation improves the diagnostic accuracy of ultrasound in verifying NGT position. It is a quick investigation such that fasting time of patients and their length of ED stay can be shortened.
Persistent Identifierhttp://hdl.handle.net/10722/239775
ISSN
2023 Impact Factor: 2.7
2023 SCImago Journal Rankings: 0.858
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorWong, Kin Wa-
dc.contributor.authorChan, Hok Hang-
dc.contributor.authorWong, Chi Pang-
dc.contributor.authorChan, Ming Yin-
dc.contributor.authorChau, Jeffrey Cheuk Wai-
dc.contributor.authorWong, Tai Wai-
dc.date.accessioned2017-04-03T02:41:23Z-
dc.date.available2017-04-03T02:41:23Z-
dc.date.issued2017-
dc.identifier.citationAmerican Journal of Emergency Medicine, 2017, v. 35, n. 2, p. 333-336-
dc.identifier.issn0735-6757-
dc.identifier.urihttp://hdl.handle.net/10722/239775-
dc.description.abstract© 2016 Elsevier Inc.Objectives Previous studies have shown that ultrasonography (USG), as an alternative to radiography, has a good accuracy in confirming nasogastric tube (NGT) position. Color flow detection of air insufflation is a novel approach in verifying NGT position. In our study, we aimed at evaluating its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in confirming the NGT position, as compared with 2-dimensional (2D) USG. Methods The study was conducted on adult patients over a period of 38 months in an emergency department in Hong Kong. 2D USG and color flow Doppler imaging were conducted for each subject. Chest X-ray was used as the gold standard for NGT position confirmation. Results 100 patients (59 males and 41 females) were recruited totally. Their mean age was 82. The sensitivity, specificity, PPV and NPV of 2D USG were 11.1% (95% CI 4.6%–17.6%), 100% (95% CI 100%–100%), 100% (95% CI 100%–100%), and 11.1% (95% CI 4.6%–17.6%) respectively. For color flow Doppler USG, the sensitivity, specificity, PPV and NPV were 90% (95% CI 83.7%–96.2%), 80% (95% CI 55.2%–100%), 97.6% (95% CI 94.3%–100%), and 47.1% (95% CI 23.3%–70.8%) respectively. The overall accuracy of color Doppler imaging was 89%, which was higher than that of 2D USG (20% only). Conclusions Color flow detection of air insufflation improves the diagnostic accuracy of ultrasound in verifying NGT position. It is a quick investigation such that fasting time of patients and their length of ED stay can be shortened.-
dc.languageeng-
dc.relation.ispartofAmerican Journal of Emergency Medicine-
dc.subjectSensitivity-
dc.subjectNasogastric tube-
dc.subjectAir insufflation-
dc.subjectColor Doppler-
dc.subjectUltrasound-
dc.subjectSpecificity-
dc.titleUsing color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.ajem.2016.12.046-
dc.identifier.scopuseid_2-s2.0-85009250491-
dc.identifier.volume35-
dc.identifier.issue2-
dc.identifier.spage333-
dc.identifier.epage336-
dc.identifier.eissn1532-8171-
dc.identifier.isiWOS:000394924600026-
dc.identifier.issnl0735-6757-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats