Article: Assessment of smoking behaviour in the dental setting. A study comparing self-reported questionnaire data and exhaled carbon monoxide levels
Title | Assessment of smoking behaviour in the dental setting. A study comparing self-reported questionnaire data and exhaled carbon monoxide levels |
---|---|
Authors | |
Keywords | Smoking cessation Exhaled carbon monoxide Self-reported Smoking Dental setting Oral diseases |
Issue Date | 2012 |
Citation | Clinical Oral Investigations, 2012, v. 16, n. 3, p. 755-760 How to Cite? |
Abstract | The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting. © 2011 Springer-Verlag. |
Persistent Identifier | http://hdl.handle.net/10722/236194 |
ISSN | 2023 Impact Factor: 3.1 2023 SCImago Journal Rankings: 0.942 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Frei, Marc | - |
dc.contributor.author | Engel Brügger, Odette | - |
dc.contributor.author | Sendi, Pedram | - |
dc.contributor.author | Reichart, Peter A. | - |
dc.contributor.author | Ramseier, Christoph A. | - |
dc.contributor.author | Bornstein, Michael M. | - |
dc.date.accessioned | 2016-11-11T07:43:11Z | - |
dc.date.available | 2016-11-11T07:43:11Z | - |
dc.date.issued | 2012 | - |
dc.identifier.citation | Clinical Oral Investigations, 2012, v. 16, n. 3, p. 755-760 | - |
dc.identifier.issn | 1432-6981 | - |
dc.identifier.uri | http://hdl.handle.net/10722/236194 | - |
dc.description.abstract | The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting. © 2011 Springer-Verlag. | - |
dc.language | eng | - |
dc.relation.ispartof | Clinical Oral Investigations | - |
dc.subject | Smoking cessation | - |
dc.subject | Exhaled carbon monoxide | - |
dc.subject | Self-reported | - |
dc.subject | Smoking | - |
dc.subject | Dental setting | - |
dc.subject | Oral diseases | - |
dc.title | Assessment of smoking behaviour in the dental setting. A study comparing self-reported questionnaire data and exhaled carbon monoxide levels | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1007/s00784-011-0583-2 | - |
dc.identifier.pmid | 21717094 | - |
dc.identifier.scopus | eid_2-s2.0-84861768624 | - |
dc.identifier.volume | 16 | - |
dc.identifier.issue | 3 | - |
dc.identifier.spage | 755 | - |
dc.identifier.epage | 760 | - |
dc.identifier.eissn | 1436-3771 | - |
dc.identifier.isi | WOS:000304173900009 | - |
dc.identifier.issnl | 1432-6981 | - |