File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Consensual ophthalmotonic reaction in Chinese patients following augmented trabeculectomy or ExPRESS shunt implantation

TitleConsensual ophthalmotonic reaction in Chinese patients following augmented trabeculectomy or ExPRESS shunt implantation
Authors
KeywordsConsensual ophthalmotonic reaction
ExPRESS shunt
Glaucoma surgery
Intraocular pressure
Trabeculectomy
Issue Date2016
PublisherLippincott Williams & Wilkins. The Journal's web site is located at http://www.md-journal.com
Citation
Medicine (Baltimore), 2016, v. 95 n. 29, p. article no .e4190 How to Cite?
AbstractINTRODUCTION: Consensual ophthalmotonic reaction (COR) was first described in 1924. Studies following monocular application of glaucoma drops and laser trabeculoplasty showed a drop in fellow eye intraocular pressure (IOP). However, studies following monocular surgery showed heterogeneous results. The purpose of this study was to investigate the COR in Chinese patients who have received monocular filtration surgery. METHODS: A noncomparative retrospective study of 65 eyes undergoing filtration surgery in Queen Mary Hospital was conducted. The IOP was obtained at baseline and postoperative days 1, 3, 7 and 14. Patient's age, sex, type of glaucoma and surgery, preoperative medications, postoperative bleb status, and number of interventions were tabulated. The postoperative IOP measurements over both eyes were obtained, and the readings were averaged to decrease the chances of extreme readings being a one-off event and allow for regression to the mean bias. RESULTS: COR was observed in the unoperated fellow eye. The mean preoperative IOP and averaged postoperative IOP were 17.2 +/- 5.2 mm Hg and 20.1 +/- 8.9 mm Hg, respectively (P < 0.04). All medications were continued in the fellow eye or even stepped up. Twenty-three percent of patients demonstrated fellow eye IOP rise >30% from baseline, while none showed IOP drop >30% from baseline. DISCUSSION: Following monocular penetrating filtration surgery, our Chinese population demonstrated a significant fellow eye IOP increase in the early postoperative period. We should bear in mind the influence of COR and take care to measure the fellow eye IOP following monocular surgery.
Persistent Identifierhttp://hdl.handle.net/10722/233666
ISSN
2021 Impact Factor: 1.817
2020 SCImago Journal Rankings: 0.590
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorShum, JWH-
dc.contributor.authorChoy, NKB-
dc.contributor.authorHo, WL-
dc.contributor.authorChan, JCH-
dc.contributor.authorLai, JSM-
dc.date.accessioned2016-09-20T05:38:19Z-
dc.date.available2016-09-20T05:38:19Z-
dc.date.issued2016-
dc.identifier.citationMedicine (Baltimore), 2016, v. 95 n. 29, p. article no .e4190-
dc.identifier.issn0025-7974-
dc.identifier.urihttp://hdl.handle.net/10722/233666-
dc.description.abstractINTRODUCTION: Consensual ophthalmotonic reaction (COR) was first described in 1924. Studies following monocular application of glaucoma drops and laser trabeculoplasty showed a drop in fellow eye intraocular pressure (IOP). However, studies following monocular surgery showed heterogeneous results. The purpose of this study was to investigate the COR in Chinese patients who have received monocular filtration surgery. METHODS: A noncomparative retrospective study of 65 eyes undergoing filtration surgery in Queen Mary Hospital was conducted. The IOP was obtained at baseline and postoperative days 1, 3, 7 and 14. Patient's age, sex, type of glaucoma and surgery, preoperative medications, postoperative bleb status, and number of interventions were tabulated. The postoperative IOP measurements over both eyes were obtained, and the readings were averaged to decrease the chances of extreme readings being a one-off event and allow for regression to the mean bias. RESULTS: COR was observed in the unoperated fellow eye. The mean preoperative IOP and averaged postoperative IOP were 17.2 +/- 5.2 mm Hg and 20.1 +/- 8.9 mm Hg, respectively (P < 0.04). All medications were continued in the fellow eye or even stepped up. Twenty-three percent of patients demonstrated fellow eye IOP rise >30% from baseline, while none showed IOP drop >30% from baseline. DISCUSSION: Following monocular penetrating filtration surgery, our Chinese population demonstrated a significant fellow eye IOP increase in the early postoperative period. We should bear in mind the influence of COR and take care to measure the fellow eye IOP following monocular surgery.-
dc.languageeng-
dc.publisherLippincott Williams & Wilkins. The Journal's web site is located at http://www.md-journal.com-
dc.relation.ispartofMedicine (Baltimore)-
dc.rightsThis is a non-final version of an article published in final form in (provide complete journal citation)-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectConsensual ophthalmotonic reaction-
dc.subjectExPRESS shunt-
dc.subjectGlaucoma surgery-
dc.subjectIntraocular pressure-
dc.subjectTrabeculectomy-
dc.titleConsensual ophthalmotonic reaction in Chinese patients following augmented trabeculectomy or ExPRESS shunt implantation-
dc.typeArticle-
dc.identifier.emailShum, JWH: jenni101@hku.hk-
dc.identifier.emailChoy, NKB: bnkchoy@hku.hk-
dc.identifier.emailHo, WL: hwl069@hku.hk-
dc.identifier.emailChan, JCH: jonochan@hkucc.hku.hk-
dc.identifier.emailLai, JSM: laism@hku.hk-
dc.identifier.authorityShum, JWH=rp01849-
dc.identifier.authorityChoy, NKB=rp01795-
dc.identifier.authorityChan, JCH=rp02113-
dc.identifier.authorityLai, JSM=rp00295-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.1097/md.0000000000004190-
dc.identifier.scopuseid_2-s2.0-84980034405-
dc.identifier.hkuros264621-
dc.identifier.volume95-
dc.identifier.issue29-
dc.identifier.spagearticle no .e4190-
dc.identifier.epagearticle no .e4190-
dc.identifier.isiWOS:000380768000012-
dc.publisher.placeUnited States-
dc.identifier.issnl0025-7974-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats