File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Ovarian Response and Cumulative Live Birth Rate of Women Undergoing In-Vitro Fertilisation Who Had Discordant Anti-Mullerian Hormone and Antral Follicle Count Measurements: A Retrospective Study

TitleOvarian Response and Cumulative Live Birth Rate of Women Undergoing In-Vitro Fertilisation Who Had Discordant Anti-Mullerian Hormone and Antral Follicle Count Measurements: A Retrospective Study
Authors
Issue Date2014
PublisherPublic Library of Science. The Journal's web site is located at http://www.plosone.org/home.action
Citation
PLoS One, 2014, v. 9 n. 10, p. Article no. e108493 How to Cite?
AbstractOBJECTIVE: To evaluate ovarian response and cumulative live birth rate of women undergoing in-vitro fertilization (IVF) treatment who had discordant baseline serum anti-Mullerian hormone (AMH) level and antral follicle count (AFC). METHODS: This is a retrospective cohort study on 1,046 women undergoing the first IVF cycle in Queen Mary Hospital, Hong Kong. Subjects receiving standard IVF treatment with the GnRH agonist long protocol were classified according to their quartiles of baseline AMH and AFC measurements after GnRH agonist down-regulation and before commencing ovarian stimulation. The number of retrieved oocytes, ovarian sensitivity index (OSI) and cumulative live-birth rate for each classification category were compared. RESULTS: Among our studied subjects, 32.2% were discordant in their AMH and AFC quartiles. Among them, those having higher AMH within the same AFC quartile had higher number of retrieved oocytes and cumulative live-birth rate. Subjects discordant in AMH and AFC had intermediate OSI which differed significantly compared to those concordant in AMH and AFC on either end. OSI of those discordant in AMH and AFC did not differ significantly whether either AMH or AFC quartile was higher than the other. CONCLUSIONS: When AMH and AFC are discordant, the ovarian responsiveness is intermediate between that when both are concordant on either end. Women having higher AMH within the same AFC quartile had higher number of retrieved oocytes and cumulative live-birth rate.
Persistent Identifierhttp://hdl.handle.net/10722/219178
ISSN
2021 Impact Factor: 3.752
2020 SCImago Journal Rankings: 0.990
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLi, RHW-
dc.contributor.authorLee, VCY-
dc.contributor.authorLau, EYL-
dc.contributor.authorYeung, WSB-
dc.contributor.authorHo, PC-
dc.contributor.authorNg, EHY-
dc.date.accessioned2015-09-18T07:16:13Z-
dc.date.available2015-09-18T07:16:13Z-
dc.date.issued2014-
dc.identifier.citationPLoS One, 2014, v. 9 n. 10, p. Article no. e108493-
dc.identifier.issn1932-6203-
dc.identifier.urihttp://hdl.handle.net/10722/219178-
dc.description.abstractOBJECTIVE: To evaluate ovarian response and cumulative live birth rate of women undergoing in-vitro fertilization (IVF) treatment who had discordant baseline serum anti-Mullerian hormone (AMH) level and antral follicle count (AFC). METHODS: This is a retrospective cohort study on 1,046 women undergoing the first IVF cycle in Queen Mary Hospital, Hong Kong. Subjects receiving standard IVF treatment with the GnRH agonist long protocol were classified according to their quartiles of baseline AMH and AFC measurements after GnRH agonist down-regulation and before commencing ovarian stimulation. The number of retrieved oocytes, ovarian sensitivity index (OSI) and cumulative live-birth rate for each classification category were compared. RESULTS: Among our studied subjects, 32.2% were discordant in their AMH and AFC quartiles. Among them, those having higher AMH within the same AFC quartile had higher number of retrieved oocytes and cumulative live-birth rate. Subjects discordant in AMH and AFC had intermediate OSI which differed significantly compared to those concordant in AMH and AFC on either end. OSI of those discordant in AMH and AFC did not differ significantly whether either AMH or AFC quartile was higher than the other. CONCLUSIONS: When AMH and AFC are discordant, the ovarian responsiveness is intermediate between that when both are concordant on either end. Women having higher AMH within the same AFC quartile had higher number of retrieved oocytes and cumulative live-birth rate.-
dc.languageeng-
dc.publisherPublic Library of Science. The Journal's web site is located at http://www.plosone.org/home.action-
dc.relation.ispartofPLoS ONE-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.titleOvarian Response and Cumulative Live Birth Rate of Women Undergoing In-Vitro Fertilisation Who Had Discordant Anti-Mullerian Hormone and Antral Follicle Count Measurements: A Retrospective Study-
dc.typeArticle-
dc.identifier.emailLi, RHW: raymondli@hku.hk-
dc.identifier.emailLee, VCY: v200lee@hku.hk-
dc.identifier.emailLau, EYL: eyllau@hkucc.hku.hk-
dc.identifier.emailYeung, WSB: wsbyeung@hku.hk-
dc.identifier.emailHo, PC: pcho@hku.hk-
dc.identifier.emailNg, EHY: nghye@hku.hk-
dc.identifier.authorityLi, RHW=rp01649-
dc.identifier.authorityYeung, WSB=rp00331-
dc.identifier.authorityHo, PC=rp00325-
dc.identifier.authorityNg, EHY=rp00426-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.1371/journal.pone.0108493-
dc.identifier.pmid25313856-
dc.identifier.scopuseid_2-s2.0-84908099214-
dc.identifier.hkuros252316-
dc.identifier.volume9-
dc.identifier.issue10-
dc.identifier.spageArticle no. e108493-
dc.identifier.epageArticle no. e108493-
dc.identifier.isiWOS:000343662500014-
dc.publisher.placeUnited States-
dc.identifier.issnl1932-6203-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats