File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Appears in Collections:
Article: A Log-normal δ-Shock maintenance model for a deteriorating system
Title | A Log-normal δ-Shock maintenance model for a deteriorating system 退化系統的對數正態δ沖擊維修模型 |
---|---|
Authors | |
Keywords | δ-shock (δ沖擊) Renewal process (更新過程) Geometric process (幾何過程) Replacement policy N (更換策略N) |
Issue Date | 2006 |
Publisher | Sichuan University (四川大學). |
Citation | Journal of Sichuan University (Natural Science Edition), 2006, v. 43 n. 1, p. 59-65 How to Cite? 四川大學學報 (自然科學版), 2006, v. 43 n. 1, p. 59-65 How to Cite? |
Abstract | In this paper,a δ-shock maintenance model for a deteriorating system is studied.Assume that shocks arrive according to a renewal process,the inter-arrival time of shocks has a log-normal distribution.Whenever an inter-arrival time of shocks is less than a threshold,the system will fail.A replacement policy N is adopted by which the system will be replaced by an identical new one at the time following the Nth failure.Then the long-run average cost per unit time is evaluated and an analytic expression for the optimal replacement policy N~* is given.
研究了一類退化系統的δ沖擊模型.假定沖擊來自于一個具有對數正態分布更新間距的更新過程,當沖擊之間的間距小于一個閾值時,系統就會失效.作者采用更換策略N,即當且僅當系統已經失效N次時用一個全新的系統更換,然后得到了系統長期運行下的平均費用的表達式,并且找到了最優更換策略N*的解析表達式,最后給出了一個數值實例. |
Persistent Identifier | http://hdl.handle.net/10722/213735 |
ISSN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Tang, YY | - |
dc.contributor.author | Lam, Y | - |
dc.date.accessioned | 2015-08-14T06:30:01Z | - |
dc.date.available | 2015-08-14T06:30:01Z | - |
dc.date.issued | 2006 | - |
dc.identifier.citation | Journal of Sichuan University (Natural Science Edition), 2006, v. 43 n. 1, p. 59-65 | - |
dc.identifier.citation | 四川大學學報 (自然科學版), 2006, v. 43 n. 1, p. 59-65 | - |
dc.identifier.issn | 0490-6756 | - |
dc.identifier.uri | http://hdl.handle.net/10722/213735 | - |
dc.description.abstract | In this paper,a δ-shock maintenance model for a deteriorating system is studied.Assume that shocks arrive according to a renewal process,the inter-arrival time of shocks has a log-normal distribution.Whenever an inter-arrival time of shocks is less than a threshold,the system will fail.A replacement policy N is adopted by which the system will be replaced by an identical new one at the time following the Nth failure.Then the long-run average cost per unit time is evaluated and an analytic expression for the optimal replacement policy N~* is given. 研究了一類退化系統的δ沖擊模型.假定沖擊來自于一個具有對數正態分布更新間距的更新過程,當沖擊之間的間距小于一個閾值時,系統就會失效.作者采用更換策略N,即當且僅當系統已經失效N次時用一個全新的系統更換,然后得到了系統長期運行下的平均費用的表達式,并且找到了最優更換策略N*的解析表達式,最后給出了一個數值實例. | - |
dc.language | eng | - |
dc.publisher | Sichuan University (四川大學). | - |
dc.relation.ispartof | Journal of Sichuan University (Natural Science Edition) | - |
dc.relation.ispartof | 四川大學學報 (自然科學版) | - |
dc.subject | δ-shock (δ沖擊) | - |
dc.subject | Renewal process (更新過程) | - |
dc.subject | Geometric process (幾何過程) | - |
dc.subject | Replacement policy N (更換策略N) | - |
dc.title | A Log-normal δ-Shock maintenance model for a deteriorating system | - |
dc.title | 退化系統的對數正態δ沖擊維修模型 | - |
dc.type | Article | - |
dc.identifier.email | Lam, Y: lamy@hkucc.hku.hk | - |
dc.identifier.hkuros | 115015 | - |
dc.identifier.volume | 43 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 59 | - |
dc.identifier.epage | 65 | - |
dc.publisher.place | China (中國) | - |
dc.identifier.issnl | 0490-6756 | - |