File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1120/jacmp.v14i4.4229
- Scopus: eid_2-s2.0-84880668926
- PMID: 23835388
- WOS: WOS:000324164200013
Supplementary
- Citations:
- Appears in Collections:
Article: Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy
Title | Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy |
---|---|
Authors | |
Keywords | 4D dose calculation CyberKnife SBRT Volumetric-modulated arc radiotherapy |
Issue Date | 2013 |
Publisher | American College of Medical Physics. The Journal's web site is located at http://www.jacmp.org/ |
Citation | Journal of Applied Clinical Medical Physics, 2013, v. 14 n. 4, p. 136-149 How to Cite? |
Persistent Identifier | http://hdl.handle.net/10722/202751 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | CHAN, KH | en_US |
dc.contributor.author | Kwong, DLW | en_US |
dc.contributor.author | Law, GM | en_US |
dc.contributor.author | Tam, E | en_US |
dc.contributor.author | Tong, A | en_US |
dc.contributor.author | Lee, V | en_US |
dc.contributor.author | Ng, CY | en_US |
dc.date.accessioned | 2014-09-19T09:33:35Z | - |
dc.date.available | 2014-09-19T09:33:35Z | - |
dc.date.issued | 2013 | en_US |
dc.identifier.citation | Journal of Applied Clinical Medical Physics, 2013, v. 14 n. 4, p. 136-149 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/202751 | - |
dc.language | eng | en_US |
dc.publisher | American College of Medical Physics. The Journal's web site is located at http://www.jacmp.org/ | - |
dc.relation.ispartof | Journal of Applied Clinical Medical Physics | en_US |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.subject | 4D dose calculation | - |
dc.subject | CyberKnife | - |
dc.subject | SBRT | - |
dc.subject | Volumetric-modulated arc radiotherapy | - |
dc.title | Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy | en_US |
dc.type | Article | en_US |
dc.identifier.email | Kwong, DLW: dlwkwong@hku.hk | en_US |
dc.identifier.email | Ng, CY: ngchoryi@hku.hk | en_US |
dc.identifier.authority | Kwong, DLW=rp00414 | en_US |
dc.description.nature | published_or_final_version | - |
dc.identifier.doi | 10.1120/jacmp.v14i4.4229 | en_US |
dc.identifier.pmid | 23835388 | - |
dc.identifier.scopus | eid_2-s2.0-84880668926 | - |
dc.identifier.hkuros | 240091 | en_US |
dc.identifier.volume | 14 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.spage | 136 | en_US |
dc.identifier.epage | 149 | en_US |
dc.identifier.isi | WOS:000324164200013 | - |