File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

postgraduate thesis: Odour control and management in Hong Kong sewage treatment infrastructures

TitleOdour control and management in Hong Kong sewage treatment infrastructures
Authors
Issue Date2013
PublisherThe University of Hong Kong (Pokfulam, Hong Kong)
Citation
Wong, Y. [黃英健]. (2013). Odour control and management in Hong Kong sewage treatment infrastructures. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b5099171
AbstractMany complaints were received from the residential area around the Shatin Sewage Treatment Works (STSTW) about the presence of odour. The dominant odour marker H2S was selected to be studied. A review of the odour measurement and sampling methods, together with the specification of the standard limits and health effects were made. The formation process of H2S was investigated and the abatement and control measures in terms of physical, chemical and biological techniques were compared. The monthly rate of H2S emission in the atmosphere was calculated from the soluble sulfide and the measured wastewater flow at the inlet works, primary sedimentation tanks, aeration tanks, and sludge digestive and storage tanks, and the H2S mapping was carried out at the same places. Meteorological data including wind speed, wind direction, temperature and pressure were collected. The effect of temperature and pH on H2S generation is shown, and the effectiveness of odour control and deodourization processes was studied. A Gaussian dispersion model of Industrial Source Complex version 3 (ISC3) was applied in predicting the ground H2S level at various air sensitive receivers in the vicinity of STSTW. None of the places exceeded the recommended H2S concentration of World Health Organization (WHO) and the odour is a localized problem in STSTW of 35% area having H2S ranging in 0.01--‐0.023ppm. Recommendations are suggested in both short-term improvement in operation and maintenance practice and long-term design and construction of sewage treatment facilities.
DegreeMaster of Science in Environmental Management
SubjectOdor control - China - Hong Kong
Sewage disposal plants - China - Hong Kong
Dept/ProgramEnvironmental Management
Persistent Identifierhttp://hdl.handle.net/10722/194556
HKU Library Item IDb5099171

 

DC FieldValueLanguage
dc.contributor.authorWong, Ying-kin-
dc.contributor.author黃英健-
dc.date.accessioned2014-02-11T23:10:29Z-
dc.date.available2014-02-11T23:10:29Z-
dc.date.issued2013-
dc.identifier.citationWong, Y. [黃英健]. (2013). Odour control and management in Hong Kong sewage treatment infrastructures. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b5099171-
dc.identifier.urihttp://hdl.handle.net/10722/194556-
dc.description.abstractMany complaints were received from the residential area around the Shatin Sewage Treatment Works (STSTW) about the presence of odour. The dominant odour marker H2S was selected to be studied. A review of the odour measurement and sampling methods, together with the specification of the standard limits and health effects were made. The formation process of H2S was investigated and the abatement and control measures in terms of physical, chemical and biological techniques were compared. The monthly rate of H2S emission in the atmosphere was calculated from the soluble sulfide and the measured wastewater flow at the inlet works, primary sedimentation tanks, aeration tanks, and sludge digestive and storage tanks, and the H2S mapping was carried out at the same places. Meteorological data including wind speed, wind direction, temperature and pressure were collected. The effect of temperature and pH on H2S generation is shown, and the effectiveness of odour control and deodourization processes was studied. A Gaussian dispersion model of Industrial Source Complex version 3 (ISC3) was applied in predicting the ground H2S level at various air sensitive receivers in the vicinity of STSTW. None of the places exceeded the recommended H2S concentration of World Health Organization (WHO) and the odour is a localized problem in STSTW of 35% area having H2S ranging in 0.01--‐0.023ppm. Recommendations are suggested in both short-term improvement in operation and maintenance practice and long-term design and construction of sewage treatment facilities.-
dc.languageeng-
dc.publisherThe University of Hong Kong (Pokfulam, Hong Kong)-
dc.relation.ispartofHKU Theses Online (HKUTO)-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.rightsThe author retains all proprietary rights, (such as patent rights) and the right to use in future works.-
dc.subject.lcshOdor control - China - Hong Kong-
dc.subject.lcshSewage disposal plants - China - Hong Kong-
dc.titleOdour control and management in Hong Kong sewage treatment infrastructures-
dc.typePG_Thesis-
dc.identifier.hkulb5099171-
dc.description.thesisnameMaster of Science in Environmental Management-
dc.description.thesislevelMaster-
dc.description.thesisdisciplineEnvironmental Management-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.5353/th_b5099171-
dc.date.hkucongregation2013-
dc.identifier.mmsid991035890049703414-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats