File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Improved calibration of a large open-ended coaxial probe for dielectric measurements

TitleImproved calibration of a large open-ended coaxial probe for dielectric measurements
Authors
Issue Date1991
Citation
Ieee Transactions On Instrumentation And Measurement, 1991, v. 40 n. 4, p. 742-746 How to Cite?
AbstractAn improved method for calibrating an open-ended coaxial sensor is proposed. The calibration utilizes the measurements of an open, a short, and a short-cavity. These terminations are inexpensive to make and result in a calibration that depends only on the geometry of the sensor. The short-cavity is modeled by waveguide modal techniques and the theoretical reflection coefficient determined to any accuracy. Consequently, an improvement in the accuracy of the measurements is obtained over a large bandwidth. The calibration was tested by comparing theoretical and experimental values of the complex permittivity for common liquids, and the discrepancy was seen to be small.
Persistent Identifierhttp://hdl.handle.net/10722/182515
ISSN
2023 Impact Factor: 5.6
2023 SCImago Journal Rankings: 1.536
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorOtto, GPen_US
dc.contributor.authorChew, WCen_US
dc.date.accessioned2013-05-02T05:15:41Z-
dc.date.available2013-05-02T05:15:41Z-
dc.date.issued1991en_US
dc.identifier.citationIeee Transactions On Instrumentation And Measurement, 1991, v. 40 n. 4, p. 742-746en_US
dc.identifier.issn0018-9456en_US
dc.identifier.urihttp://hdl.handle.net/10722/182515-
dc.description.abstractAn improved method for calibrating an open-ended coaxial sensor is proposed. The calibration utilizes the measurements of an open, a short, and a short-cavity. These terminations are inexpensive to make and result in a calibration that depends only on the geometry of the sensor. The short-cavity is modeled by waveguide modal techniques and the theoretical reflection coefficient determined to any accuracy. Consequently, an improvement in the accuracy of the measurements is obtained over a large bandwidth. The calibration was tested by comparing theoretical and experimental values of the complex permittivity for common liquids, and the discrepancy was seen to be small.en_US
dc.languageengen_US
dc.relation.ispartofIEEE Transactions on Instrumentation and Measurementen_US
dc.titleImproved calibration of a large open-ended coaxial probe for dielectric measurementsen_US
dc.typeArticleen_US
dc.identifier.emailChew, WC: wcchew@hku.hken_US
dc.identifier.authorityChew, WC=rp00656en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/19.85345en_US
dc.identifier.scopuseid_2-s2.0-0026204853en_US
dc.identifier.volume40en_US
dc.identifier.issue4en_US
dc.identifier.spage742en_US
dc.identifier.epage746en_US
dc.identifier.isiWOS:A1991GB24600014-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridOtto, GP=35446329800en_US
dc.identifier.scopusauthoridChew, WC=36014436300en_US
dc.identifier.issnl0018-9456-

Export via OAI-PMH Interface in XML Formats