File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Scopus: eid_2-s2.0-3042795847
- WOS: WOS:000224100300015
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Determination of fluoride in water by reversed-phase high-performance liquid chromatography using F-La3+-alizarin complexone ternary complex
Title | Determination of fluoride in water by reversed-phase high-performance liquid chromatography using F-La3+-alizarin complexone ternary complex |
---|---|
Authors | |
Keywords | Column Liquid Chromatography Fluoride - Alizarin Complex Fluoride In River And Tap Water |
Issue Date | 2004 |
Publisher | Friedr Vieweg und Sohn Verlagsgesellschaft mbH. The Journal's web site is located at http://www.elsevier.com/locate/chromatographia |
Citation | Chromatographia, 2004, v. 59 n. 11-12, p. 745-747 How to Cite? |
Abstract | A method for the determination of fluoride by reversed-phase, high-performance liquid chromatography (RP-HPLC) is described. Fluoride, La 3+ and alizarin complexone form F-La3+-alizarin complexone ternary complex, which is separated from the matrix on a RP, Ultrasphere C 18 column (250 x 4.6 mm, 5 μm) using methanol-water (19:81, v/v] mobile phase at 1.00 ml min-1; detection at 568 nm. The calibration graph was linear from 1.0-150 ng mL-1 for fluoride with a correlation coefficient: 0.9993 (n = 6). The detection limit was 0.2 ng mL-1. The method was successfully applied to the determination of fluoride in river and tap water. Recovery was: 94-102%, RSD in the range: 1.9-3.6%. |
Persistent Identifier | http://hdl.handle.net/10722/178921 |
ISSN | 2023 Impact Factor: 1.2 2023 SCImago Journal Rankings: 0.301 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Xu, XR | en_US |
dc.contributor.author | Li, HB | en_US |
dc.contributor.author | Gu, JD | en_US |
dc.contributor.author | Paeng, KJ | en_US |
dc.date.accessioned | 2012-12-19T09:50:45Z | - |
dc.date.available | 2012-12-19T09:50:45Z | - |
dc.date.issued | 2004 | en_US |
dc.identifier.citation | Chromatographia, 2004, v. 59 n. 11-12, p. 745-747 | en_US |
dc.identifier.issn | 0009-5893 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/178921 | - |
dc.description.abstract | A method for the determination of fluoride by reversed-phase, high-performance liquid chromatography (RP-HPLC) is described. Fluoride, La 3+ and alizarin complexone form F-La3+-alizarin complexone ternary complex, which is separated from the matrix on a RP, Ultrasphere C 18 column (250 x 4.6 mm, 5 μm) using methanol-water (19:81, v/v] mobile phase at 1.00 ml min-1; detection at 568 nm. The calibration graph was linear from 1.0-150 ng mL-1 for fluoride with a correlation coefficient: 0.9993 (n = 6). The detection limit was 0.2 ng mL-1. The method was successfully applied to the determination of fluoride in river and tap water. Recovery was: 94-102%, RSD in the range: 1.9-3.6%. | en_US |
dc.language | eng | en_US |
dc.publisher | Friedr Vieweg und Sohn Verlagsgesellschaft mbH. The Journal's web site is located at http://www.elsevier.com/locate/chromatographia | en_US |
dc.relation.ispartof | Chromatographia | en_US |
dc.subject | Column Liquid Chromatography | en_US |
dc.subject | Fluoride - Alizarin Complex | en_US |
dc.subject | Fluoride In River And Tap Water | en_US |
dc.title | Determination of fluoride in water by reversed-phase high-performance liquid chromatography using F-La3+-alizarin complexone ternary complex | en_US |
dc.type | Article | en_US |
dc.identifier.email | Gu, JD: jdgu@hkucc.hku.hk | en_US |
dc.identifier.authority | Gu, JD=rp00701 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.scopus | eid_2-s2.0-3042795847 | en_US |
dc.identifier.hkuros | 89775 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-3042795847&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 59 | en_US |
dc.identifier.issue | 11-12 | en_US |
dc.identifier.spage | 745 | en_US |
dc.identifier.epage | 747 | en_US |
dc.identifier.isi | WOS:000224100300015 | - |
dc.publisher.place | Germany | en_US |
dc.identifier.scopusauthorid | Xu, XR=7405293882 | en_US |
dc.identifier.scopusauthorid | Li, HB=25649944400 | en_US |
dc.identifier.scopusauthorid | Gu, JD=7403129601 | en_US |
dc.identifier.scopusauthorid | Paeng, KJ=7003279415 | en_US |
dc.identifier.issnl | 0009-5893 | - |