File Download
There are no files associated with this item.
Supplementary
- Citations:
- Appears in Collections:
Article: Short-term results of using Lamellar Corneo-scleral patch graft for the Ahmed glaucoma valve implant surgery.
Title | Short-term results of using Lamellar Corneo-scleral patch graft for the Ahmed glaucoma valve implant surgery. |
---|---|
Authors | |
Issue Date | 1997 |
Citation | Eye Science, 1997, v. 13 n. 3, p. 109-112 How to Cite? 眼科學報, 1997, v. 13 n. 3, p. 109-112 How to Cite? |
Abstract | BACKGROUND: Human donor sclera is commonly used in glaucoma implant surgery to cover the external portiori of the silicone tube and prevent its erosion through the overlying conjunctiva. Corneo-scleral graft is used in this study as an alternative material for its desirable properties of being transparent, higher in tensile strength, cheap and more readily available. METHODS: Eighteen consecutive cases were implanted with the Ahmed glaucoma valve implant. The limbal portion of the silicone tube was covered by a corneo-scleral graft obtained from the corneo-scleral rim left over following corneal transplant operation. The effectiveness in protecting the tube from erosion or migration, the transparency of the patch graft and complications encountered after surgery were assessed. RESULTS: At a mean follow-up of 6 months, all tubes were well protected and no complications related to the patch graft were encountered during intra and postoperative period. All corneo-scleral grafts remained transparent and healthy at the latest follow-up. CONCLUSION: Lamellar corneo-scleral tissue from residual corneal transplant material, with its many unique properties and advantages, appears to be a cheap, easily available and effective patch graft material for glaucoma implant surgery. Further explorations and studies on this material are recommended. |
Persistent Identifier | http://hdl.handle.net/10722/176350 |
ISSN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lam, DS | en_US |
dc.contributor.author | Cheuk, W | en_US |
dc.contributor.author | Lai, JS | en_US |
dc.date.accessioned | 2012-11-26T09:10:45Z | - |
dc.date.available | 2012-11-26T09:10:45Z | - |
dc.date.issued | 1997 | en_US |
dc.identifier.citation | Eye Science, 1997, v. 13 n. 3, p. 109-112 | en_US |
dc.identifier.citation | 眼科學報, 1997, v. 13 n. 3, p. 109-112 | - |
dc.identifier.issn | 1000-4432 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/176350 | - |
dc.description.abstract | BACKGROUND: Human donor sclera is commonly used in glaucoma implant surgery to cover the external portiori of the silicone tube and prevent its erosion through the overlying conjunctiva. Corneo-scleral graft is used in this study as an alternative material for its desirable properties of being transparent, higher in tensile strength, cheap and more readily available. METHODS: Eighteen consecutive cases were implanted with the Ahmed glaucoma valve implant. The limbal portion of the silicone tube was covered by a corneo-scleral graft obtained from the corneo-scleral rim left over following corneal transplant operation. The effectiveness in protecting the tube from erosion or migration, the transparency of the patch graft and complications encountered after surgery were assessed. RESULTS: At a mean follow-up of 6 months, all tubes were well protected and no complications related to the patch graft were encountered during intra and postoperative period. All corneo-scleral grafts remained transparent and healthy at the latest follow-up. CONCLUSION: Lamellar corneo-scleral tissue from residual corneal transplant material, with its many unique properties and advantages, appears to be a cheap, easily available and effective patch graft material for glaucoma implant surgery. Further explorations and studies on this material are recommended. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Yan ke xue bao = Eye science / "Yan ke xue bao" bian ji bu | en_US |
dc.relation.ispartof | 眼科學報 | - |
dc.subject.mesh | Adolescent | en_US |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Child | en_US |
dc.subject.mesh | Corneal Transplantation - Methods | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Glaucoma - Surgery | en_US |
dc.subject.mesh | Glaucoma Drainage Implants | en_US |
dc.subject.mesh | Glaucoma, Neovascular - Surgery | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Middle Aged | en_US |
dc.subject.mesh | Prospective Studies | en_US |
dc.subject.mesh | Sclera - Transplantation | en_US |
dc.title | Short-term results of using Lamellar Corneo-scleral patch graft for the Ahmed glaucoma valve implant surgery. | en_US |
dc.type | Article | en_US |
dc.identifier.email | Lai, JS: laism@hku.hk | en_US |
dc.identifier.authority | Lai, JS=rp00295 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.pmid | 11326858 | - |
dc.identifier.scopus | eid_2-s2.0-0031215544 | en_US |
dc.identifier.volume | 13 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.spage | 109 | en_US |
dc.identifier.epage | 112 | en_US |
dc.identifier.scopusauthorid | Lam, DS=35500200200 | en_US |
dc.identifier.scopusauthorid | Cheuk, W=7003958432 | en_US |
dc.identifier.scopusauthorid | Lai, JS=7401939748 | en_US |
dc.customcontrol.immutable | csl 140526 | - |
dc.identifier.issnl | 1000-4432 | - |