Article: External fixation for comminuted phalangeal fractures: A biomechanical cadaver study

TitleExternal fixation for comminuted phalangeal fractures: A biomechanical cadaver study
Authors
Issue Date1996
PublisherSage Publications Ltd.. The Journal's web site is located at http://jhs.sagepub.com
Citation
Journal Of Hand Surgery: European Volume, 1996, v. 21 n. 6, p. 760-764 How to Cite?
AbstractThe mechanical rigidity obtained by external fixation in a comminuted phalangeal fracture model was assessed and the results compared with two other types of internal fixation commonly used (lateral plate and crossed Kirschner wires) in a biomechanical cadaver study. Each fixation technique was tested in apex palmar bending, compression and torsion. The results showed that lateral plating provided the best rigidity in apex palmar bending and compression and that external fixation and Kirschner wires showed the same mechanical properties. For the torque test, external fixation provided the best rigidity. © 1996 The British Society for Surgery of the Hand. © 1996 The British Society for Surgery of the Hand.
Persistent Identifierhttp://hdl.handle.net/10722/170006
ISSN
2023 Impact Factor: 2.0
2023 SCImago Journal Rankings: 0.919
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorFitoussi, Fen_HK
dc.contributor.authorIp, WYen_HK
dc.contributor.authorChow, SPen_HK
dc.date.accessioned2012-10-30T06:04:41Z-
dc.date.available2012-10-30T06:04:41Z-
dc.date.issued1996en_HK
dc.identifier.citationJournal Of Hand Surgery: European Volume, 1996, v. 21 n. 6, p. 760-764en_HK
dc.identifier.issn1753-1934en_HK
dc.identifier.urihttp://hdl.handle.net/10722/170006-
dc.description.abstractThe mechanical rigidity obtained by external fixation in a comminuted phalangeal fracture model was assessed and the results compared with two other types of internal fixation commonly used (lateral plate and crossed Kirschner wires) in a biomechanical cadaver study. Each fixation technique was tested in apex palmar bending, compression and torsion. The results showed that lateral plating provided the best rigidity in apex palmar bending and compression and that external fixation and Kirschner wires showed the same mechanical properties. For the torque test, external fixation provided the best rigidity. © 1996 The British Society for Surgery of the Hand. © 1996 The British Society for Surgery of the Hand.en_HK
dc.languageengen_US
dc.publisherSage Publications Ltd.. The Journal's web site is located at http://jhs.sagepub.comen_HK
dc.relation.ispartofJournal of Hand Surgery: European Volumeen_HK
dc.titleExternal fixation for comminuted phalangeal fractures: A biomechanical cadaver studyen_HK
dc.typeArticleen_HK
dc.identifier.emailIp, WY: wyip@hku.hken_HK
dc.identifier.emailChow, SP: spchow@hku.hken_HK
dc.identifier.authorityIp, WY=rp00401en_HK
dc.identifier.authorityChow, SP=rp00064en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/S0266-7681(96)80182-3en_HK
dc.identifier.pmid8982919-
dc.identifier.scopuseid_2-s2.0-0029750510en_HK
dc.identifier.hkuros24955-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0029750510&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume21en_HK
dc.identifier.issue6en_HK
dc.identifier.spage760en_HK
dc.identifier.epage764en_HK
dc.identifier.isiWOS:A1996VZ71300009-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridFitoussi, F=21734031600en_HK
dc.identifier.scopusauthoridIp, WY=35549641700en_HK
dc.identifier.scopusauthoridChow, SP=7201828376en_HK
dc.identifier.issnl1753-1934-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats