Article: Fixation for comminuted phalangeal fractures: A biomechanical study of five methods
Title | Fixation for comminuted phalangeal fractures: A biomechanical study of five methods |
---|---|
Authors | |
Issue Date | 1996 |
Publisher | Sage Publications Ltd.. The Journal's web site is located at http://jhs.sagepub.com |
Citation | Journal Of Hand Surgery: European Volume, 1996, v. 21 n. 6, p. 765-767 How to Cite? |
Abstract | The rigidities of five fixation methods have been studied with a comminuted phalangeal fracture model. Mechanical testing of compression, bending and torsion were performed for each fixation. Lateral plating with six screws seems to provide the most rigid fixation. If such lateral plating is not practicable, the four-Kirschner wire method would be a satisfactory alternative. © 1996 The British Society for Surgery of the Hand. |
Persistent Identifier | http://hdl.handle.net/10722/170005 |
ISSN | 2023 Impact Factor: 2.0 2023 SCImago Journal Rankings: 0.919 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | LU, WW | en_HK |
dc.contributor.author | FurumachI, K | en_HK |
dc.contributor.author | IP, WY | en_HK |
dc.contributor.author | Chow, SP | en_HK |
dc.date.accessioned | 2012-10-30T06:04:40Z | - |
dc.date.available | 2012-10-30T06:04:40Z | - |
dc.date.issued | 1996 | en_HK |
dc.identifier.citation | Journal Of Hand Surgery: European Volume, 1996, v. 21 n. 6, p. 765-767 | en_HK |
dc.identifier.issn | 1753-1934 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/170005 | - |
dc.description.abstract | The rigidities of five fixation methods have been studied with a comminuted phalangeal fracture model. Mechanical testing of compression, bending and torsion were performed for each fixation. Lateral plating with six screws seems to provide the most rigid fixation. If such lateral plating is not practicable, the four-Kirschner wire method would be a satisfactory alternative. © 1996 The British Society for Surgery of the Hand. | en_HK |
dc.language | eng | en_US |
dc.publisher | Sage Publications Ltd.. The Journal's web site is located at http://jhs.sagepub.com | en_HK |
dc.relation.ispartof | Journal of Hand Surgery: European Volume | en_HK |
dc.title | Fixation for comminuted phalangeal fractures: A biomechanical study of five methods | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | LU, WW: wwlu@hku.hk | en_HK |
dc.identifier.email | IP, WY: wyip@hku.hk | en_HK |
dc.identifier.email | Chow, SP: spchow@hku.hk | en_HK |
dc.identifier.authority | LU, WW=rp00411 | en_HK |
dc.identifier.authority | IP, WY=rp00401 | en_HK |
dc.identifier.authority | Chow, SP=rp00064 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1016/S0266-7681(96)80183-5 | en_HK |
dc.identifier.pmid | 8982920 | - |
dc.identifier.scopus | eid_2-s2.0-0029729747 | en_HK |
dc.identifier.hkuros | 25226 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0029729747&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 21 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 765 | en_HK |
dc.identifier.epage | 767 | en_HK |
dc.identifier.isi | WOS:A1996VZ71300010 | - |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | LU, WW=7404215221 | en_HK |
dc.identifier.scopusauthorid | FurumachI, K=6506036172 | en_HK |
dc.identifier.scopusauthorid | IP, WY=35549641700 | en_HK |
dc.identifier.scopusauthorid | Chow, SP=7201828376 | en_HK |
dc.identifier.issnl | 1753-1934 | - |