Article: A piezoelectric crystal detector for water in gases

TitleA piezoelectric crystal detector for water in gases
Authors
Issue Date1960
PublisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/aca
Citation
Analytica Chimica Acta, 1960, v. 135 n. 2, p. 277-283 How to Cite?
AbstractSeveral sorbents were tested as the coating material for the construction of a water-sensitive piezoelectric crystal detector. Gelatin was found to be the most suitable. Detectors coated with various amounts of gelatin (35-150 μg) were prepared and their performance characteristics studied. The only interferences found were from volatile alcohols and formic acid. The detectors were used to determine the water content in many gaseous samples. The reliability of the method was ascertained by comparing the results with those obtained by absorption-gravimetry and by a commercially available moisture analyzer. © 1982.
Persistent Identifierhttp://hdl.handle.net/10722/168294
ISSN
2023 Impact Factor: 5.7
2023 SCImago Journal Rankings: 0.998
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLee, CWen_US
dc.contributor.authorFung, YSen_US
dc.contributor.authorFung, KWen_US
dc.date.accessioned2012-10-08T03:17:10Z-
dc.date.available2012-10-08T03:17:10Z-
dc.date.issued1960en_US
dc.identifier.citationAnalytica Chimica Acta, 1960, v. 135 n. 2, p. 277-283en_US
dc.identifier.issn0003-2670en_US
dc.identifier.urihttp://hdl.handle.net/10722/168294-
dc.description.abstractSeveral sorbents were tested as the coating material for the construction of a water-sensitive piezoelectric crystal detector. Gelatin was found to be the most suitable. Detectors coated with various amounts of gelatin (35-150 μg) were prepared and their performance characteristics studied. The only interferences found were from volatile alcohols and formic acid. The detectors were used to determine the water content in many gaseous samples. The reliability of the method was ascertained by comparing the results with those obtained by absorption-gravimetry and by a commercially available moisture analyzer. © 1982.en_US
dc.languageengen_US
dc.publisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/acaen_US
dc.relation.ispartofAnalytica Chimica Actaen_US
dc.titleA piezoelectric crystal detector for water in gasesen_US
dc.typeArticleen_US
dc.identifier.emailFung, YS:ysfung@hku.hken_US
dc.identifier.authorityFung, YS=rp00697en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/S0003-2670(01)93908-X-
dc.identifier.scopuseid_2-s2.0-4243496391en_US
dc.identifier.volume135en_US
dc.identifier.issue2en_US
dc.identifier.spage277en_US
dc.identifier.epage283en_US
dc.identifier.isiWOS:A1982NJ34900010-
dc.publisher.placeNetherlandsen_US
dc.identifier.scopusauthoridLee, CW=24744873600en_US
dc.identifier.scopusauthoridFung, YS=13309754700en_US
dc.identifier.scopusauthoridFung, KW=7202934752en_US
dc.identifier.issnl0003-2670-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats