Article: Determination of iron(III) with a copper selective electrode
| Title | Determination of iron(III) with a copper selective electrode |
|---|---|
| Authors | |
| Issue Date | 1977 |
| Publisher | American Chemical Society. The Journal's web site is located at http://pubs.acs.org/ac |
| Citation | Analytical Chemistry, 1977, v. 49 n. 3, p. 497-499 How to Cite? |
| Abstract | The application of a cupric Ion-selective electrode with a membrane of mixed Ag 2S-CuS to measure the activity of Fe(III) is presented in this paper. The method is simple and rapid with a working range from 10 -5 to 10 -2 M of Fe(III). The interference of some common cations and anions has been studied. |
| Persistent Identifier | http://hdl.handle.net/10722/167441 |
| ISSN | 2023 Impact Factor: 6.7 2023 SCImago Journal Rankings: 1.621 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Fung, YS | en_US |
| dc.contributor.author | Fung, KW | en_US |
| dc.date.accessioned | 2012-10-08T03:07:01Z | - |
| dc.date.available | 2012-10-08T03:07:01Z | - |
| dc.date.issued | 1977 | en_US |
| dc.identifier.citation | Analytical Chemistry, 1977, v. 49 n. 3, p. 497-499 | en_US |
| dc.identifier.issn | 0003-2700 | en_US |
| dc.identifier.uri | http://hdl.handle.net/10722/167441 | - |
| dc.description.abstract | The application of a cupric Ion-selective electrode with a membrane of mixed Ag 2S-CuS to measure the activity of Fe(III) is presented in this paper. The method is simple and rapid with a working range from 10 -5 to 10 -2 M of Fe(III). The interference of some common cations and anions has been studied. | en_US |
| dc.language | eng | en_US |
| dc.publisher | American Chemical Society. The Journal's web site is located at http://pubs.acs.org/ac | en_US |
| dc.relation.ispartof | Analytical Chemistry | en_US |
| dc.title | Determination of iron(III) with a copper selective electrode | en_US |
| dc.type | Article | en_US |
| dc.identifier.email | Fung, YS:ysfung@hku.hk | en_US |
| dc.identifier.authority | Fung, YS=rp00697 | en_US |
| dc.description.nature | link_to_subscribed_fulltext | en_US |
| dc.identifier.doi | 10.1021/ac50011a040 | - |
| dc.identifier.scopus | eid_2-s2.0-0017466131 | en_US |
| dc.identifier.volume | 49 | en_US |
| dc.identifier.issue | 3 | en_US |
| dc.identifier.spage | 497 | en_US |
| dc.identifier.epage | 499 | en_US |
| dc.identifier.isi | WOS:A1977CW93900037 | - |
| dc.publisher.place | United States | en_US |
| dc.identifier.scopusauthorid | Fung, YS=13309754700 | en_US |
| dc.identifier.scopusauthorid | Fung, KW=7202934752 | en_US |
| dc.identifier.issnl | 0003-2700 | - |