File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Determination of trace amounts of copper in palm oil by differential-pulse anodic-stripping voltammetry

TitleDetermination of trace amounts of copper in palm oil by differential-pulse anodic-stripping voltammetry
Authors
KeywordsCopper Determination
Differential-Pulse Anodic-Stripping Voltammetry
Palm Oil
Issue Date1980
PublisherRoyal Society of Chemistry. The Journal's web site is located at http://www.rsc.org/analyst
Citation
The Analyst, 1980, v. 105 n. 1246, p. 30-36 How to Cite?
AbstractA method is described for the determination of copper in palm oil by differential-pulse anodic-stripping voltammetry after dry ashing. Only a few grams of sample are needed and the relative standard deviation is about 3% for oils with copper contents less than 100 p.p.b. (parts per 109).
Persistent Identifierhttp://hdl.handle.net/10722/167405
ISSN
2023 Impact Factor: 3.6
2023 SCImago Journal Rankings: 0.693
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorWong, KHen_US
dc.contributor.authorFung, YSen_US
dc.contributor.authorFung, KWen_US
dc.date.accessioned2012-10-08T03:06:33Z-
dc.date.available2012-10-08T03:06:33Z-
dc.date.issued1980en_US
dc.identifier.citationThe Analyst, 1980, v. 105 n. 1246, p. 30-36en_US
dc.identifier.issn0003-2654en_US
dc.identifier.urihttp://hdl.handle.net/10722/167405-
dc.description.abstractA method is described for the determination of copper in palm oil by differential-pulse anodic-stripping voltammetry after dry ashing. Only a few grams of sample are needed and the relative standard deviation is about 3% for oils with copper contents less than 100 p.p.b. (parts per 109).en_US
dc.languageengen_US
dc.publisherRoyal Society of Chemistry. The Journal's web site is located at http://www.rsc.org/analysten_US
dc.relation.ispartofThe Analysten_US
dc.subjectCopper Determinationen_US
dc.subjectDifferential-Pulse Anodic-Stripping Voltammetryen_US
dc.subjectPalm Oilen_US
dc.titleDetermination of trace amounts of copper in palm oil by differential-pulse anodic-stripping voltammetryen_US
dc.typeArticleen_US
dc.identifier.emailFung, YS:ysfung@hku.hken_US
dc.identifier.authorityFung, YS=rp00697en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1039/AN9800500030-
dc.identifier.scopuseid_2-s2.0-0011995944en_US
dc.identifier.volume105en_US
dc.identifier.issue1246en_US
dc.identifier.spage30en_US
dc.identifier.epage36en_US
dc.identifier.isiWOS:A1980JJ65200005-
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridWong, KH=55223355500en_US
dc.identifier.scopusauthoridFung, YS=13309754700en_US
dc.identifier.scopusauthoridFung, KW=7202934752en_US
dc.identifier.issnl0003-2654-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats