Article: Concerns on installing long-throw sprinklers in tall halls

TitleConcerns on installing long-throw sprinklers in tall halls
Authors
Issue Date2012
PublisherHong Kong Polytechnic University, Construction Industry Development Studies and Research Centre. The Journal's web site is located at http://www.bse.polyu.edu.hk/researchCentre/Fire_Engineering/summary_of_output/journal/journal_EP.html
Citation
International Journal on Engineering Performance-Based Fire Codes, 2012, v. 11 n. 1, p. 1-3 How to Cite?
AbstractThere are concerns over long-throw sprinkler installation in halls with high ceilings which are likely to store large amount of combustible materials. These concerns will be addressed in this paper. At the moment, it is unknown whether such sprinkler installation can protect high-ceiling halls which store large amount of combustibles. The concept should be further explored with in-depth research through full-scale burning experiments with big fires.
Persistent Identifierhttp://hdl.handle.net/10722/163671
ISSN

 

DC FieldValueLanguage
dc.contributor.authorCheung, KPen_US
dc.contributor.authorChow, WKen_US
dc.date.accessioned2012-09-20T07:50:07Z-
dc.date.available2012-09-20T07:50:07Z-
dc.date.issued2012en_US
dc.identifier.citationInternational Journal on Engineering Performance-Based Fire Codes, 2012, v. 11 n. 1, p. 1-3en_US
dc.identifier.issn1561-9559en_US
dc.identifier.urihttp://hdl.handle.net/10722/163671-
dc.description.abstractThere are concerns over long-throw sprinkler installation in halls with high ceilings which are likely to store large amount of combustible materials. These concerns will be addressed in this paper. At the moment, it is unknown whether such sprinkler installation can protect high-ceiling halls which store large amount of combustibles. The concept should be further explored with in-depth research through full-scale burning experiments with big fires.-
dc.languageengen_US
dc.publisherHong Kong Polytechnic University, Construction Industry Development Studies and Research Centre. The Journal's web site is located at http://www.bse.polyu.edu.hk/researchCentre/Fire_Engineering/summary_of_output/journal/journal_EP.htmlen_US
dc.relation.ispartofInternational Journal on Engineering Performance-Based Fire Codesen_US
dc.titleConcerns on installing long-throw sprinklers in tall hallsen_US
dc.typeArticleen_US
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1561-9559&volume=11&issue=1&spage=1&epage=3&date=2012&atitle=Concerns+on+Installing+Long-throw+Sprinklers+in+Tall+Hallsen_US
dc.identifier.emailCheung, KP: kpcheuna@hkucc.hku.hken_US
dc.identifier.authorityCheung, KP=rp00996en_US
dc.description.naturepublished_or_final_version-
dc.identifier.hkuros211535en_US
dc.identifier.hkuros207366-
dc.identifier.volume11en_US
dc.identifier.issue1en_US
dc.identifier.spage1en_US
dc.identifier.epage3en_US
dc.publisher.placeHong Kong-
dc.identifier.issnl1561-9559-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats