Article: Pacing technology: Advances in pacing threshold management

TitlePacing technology: Advances in pacing threshold management
Authors
KeywordsAutocapture
Pacemaker
Threshold management
Issue Date2010
PublisherZheijiang University Press. The Journal's web site is located at http://www.zju.edu.cn/jzus/
Citation
Journal Of Zhejiang University: Science B, 2010, v. 11 n. 8, p. 634-638 How to Cite?
AbstractOver the last five decades, pacemaker therapy has undergone remarkable technological advances with increasing sophistication of pacemaker features. However, device longevity has remained one of the major issues in pacemaker design ever since the first endocardial pacing lead implantation in 1958. In addition to various hardware design to enhance device longevity, software-based solutions to minimize pacing energy and yet with good safety margin have also been developed. Together with desire and need of fully automatic pacing system in increasingly busy pacemaker clinic, several manufacturers have introduced different automatic threshold management algorithm. This article summarizes the current state-of-the-art management in pacing threshold in the modern pacemakers. © 2010 Zhejiang University and Springer-Verlag Berlin Heidelberg.
Persistent Identifierhttp://hdl.handle.net/10722/163328
ISSN
2021 Impact Factor: 5.552
2020 SCImago Journal Rankings: 0.624
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLau, CPen_US
dc.contributor.authorSiu, CWen_US
dc.date.accessioned2012-09-05T05:30:05Z-
dc.date.available2012-09-05T05:30:05Z-
dc.date.issued2010en_US
dc.identifier.citationJournal Of Zhejiang University: Science B, 2010, v. 11 n. 8, p. 634-638en_US
dc.identifier.issn1673-1581en_US
dc.identifier.urihttp://hdl.handle.net/10722/163328-
dc.description.abstractOver the last five decades, pacemaker therapy has undergone remarkable technological advances with increasing sophistication of pacemaker features. However, device longevity has remained one of the major issues in pacemaker design ever since the first endocardial pacing lead implantation in 1958. In addition to various hardware design to enhance device longevity, software-based solutions to minimize pacing energy and yet with good safety margin have also been developed. Together with desire and need of fully automatic pacing system in increasingly busy pacemaker clinic, several manufacturers have introduced different automatic threshold management algorithm. This article summarizes the current state-of-the-art management in pacing threshold in the modern pacemakers. © 2010 Zhejiang University and Springer-Verlag Berlin Heidelberg.en_US
dc.languageengen_US
dc.publisherZheijiang University Press. The Journal's web site is located at http://www.zju.edu.cn/jzus/en_US
dc.relation.ispartofJournal of Zhejiang University: Science Ben_US
dc.subjectAutocapture-
dc.subjectPacemaker-
dc.subjectThreshold management-
dc.subject.meshAlgorithmsen_US
dc.subject.meshAutomationen_US
dc.subject.meshCardiac Pacing, Artificial - Methodsen_US
dc.subject.meshCardiology - Methodsen_US
dc.subject.meshElectrodes, Implanteden_US
dc.subject.meshEndocardium - Pathologyen_US
dc.subject.meshEquipment Designen_US
dc.subject.meshEquipment Safetyen_US
dc.subject.meshHumansen_US
dc.subject.meshPacemaker, Artificial - Trendsen_US
dc.subject.meshSoftwareen_US
dc.titlePacing technology: Advances in pacing threshold managementen_US
dc.typeArticleen_US
dc.identifier.emailSiu, CW:cwdsiu@hkucc.hku.hken_US
dc.identifier.authoritySiu, CW=rp00534en_US
dc.description.naturelink_to_OA_fulltexten_US
dc.identifier.doi10.1631/jzus.B1001016en_US
dc.identifier.pmid20669355en_US
dc.identifier.scopuseid_2-s2.0-77955479403en_US
dc.identifier.hkuros208707-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-77955479403&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume11en_US
dc.identifier.issue8en_US
dc.identifier.spage634en_US
dc.identifier.epage638en_US
dc.identifier.isiWOS:000280598600014-
dc.publisher.placeChinaen_US
dc.identifier.scopusauthoridLau, CP=7401968501en_US
dc.identifier.scopusauthoridSiu, CW=7006550690en_US
dc.identifier.citeulike7706136-
dc.identifier.issnl1673-1581-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats