File Download
There are no files associated with this item.
Supplementary
- Citations:
- Appears in Collections:
Article: Precision surgical template for implant placement: a new systematic approach.
Title | Precision surgical template for implant placement: a new systematic approach. |
---|---|
Authors | |
Issue Date | 2002 |
Publisher | Blackwell Publishing Ltd. The Journal's web site is located at http://www.blackwellpublishing.com/journal.asp?ref=1523-0899&site=1 |
Citation | Clinical Implant Dentistry And Related Research, 2002, v. 4 n. 2, p. 88-92 How to Cite? |
Abstract | The importance of a precise surgical template for implant placement cannot be overstated. The radiographic template carries both clinical and radiographic information for the planning of fixture angulation and location. This article describes a systematic approach to the fabrication of a dual-purpose radiographic surgical template. The simple steps result in the accurate transfer of radiographic information to the surgical template with no need for complex equipment or maneuvers. key words: dental implants, implant placement, radiographic template, surgical template |
Persistent Identifier | http://hdl.handle.net/10722/154187 |
ISSN | 2023 Impact Factor: 3.7 2023 SCImago Journal Rankings: 1.302 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wat, PY | en_US |
dc.contributor.author | Chow, TW | en_US |
dc.contributor.author | Luk, HW | en_US |
dc.contributor.author | Comfort, MB | en_US |
dc.date.accessioned | 2012-08-08T08:23:46Z | - |
dc.date.available | 2012-08-08T08:23:46Z | - |
dc.date.issued | 2002 | en_US |
dc.identifier.citation | Clinical Implant Dentistry And Related Research, 2002, v. 4 n. 2, p. 88-92 | en_US |
dc.identifier.issn | 1523-0899 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/154187 | - |
dc.description.abstract | The importance of a precise surgical template for implant placement cannot be overstated. The radiographic template carries both clinical and radiographic information for the planning of fixture angulation and location. This article describes a systematic approach to the fabrication of a dual-purpose radiographic surgical template. The simple steps result in the accurate transfer of radiographic information to the surgical template with no need for complex equipment or maneuvers. key words: dental implants, implant placement, radiographic template, surgical template | en_US |
dc.language | eng | en_US |
dc.publisher | Blackwell Publishing Ltd. The Journal's web site is located at http://www.blackwellpublishing.com/journal.asp?ref=1523-0899&site=1 | en_US |
dc.relation.ispartof | Clinical implant dentistry and related research | en_US |
dc.rights | Clinical Implant Dentistry and Related Research. Copyright © Blackwell Publishing Ltd. | - |
dc.subject.mesh | Dental Implantation, Endosseous - Instrumentation | en_US |
dc.subject.mesh | Dental Implants | en_US |
dc.subject.mesh | Dental Models | en_US |
dc.subject.mesh | Equipment Design | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Image Processing, Computer-Assisted | en_US |
dc.subject.mesh | Mandible - Radiography - Surgery | en_US |
dc.subject.mesh | Maxilla - Radiography - Surgery | en_US |
dc.subject.mesh | Patient Care Planning | en_US |
dc.subject.mesh | Tomography, X-Ray | en_US |
dc.title | Precision surgical template for implant placement: a new systematic approach. | en_US |
dc.type | Article | en_US |
dc.identifier.email | Chow, TW:twchow@hku.hk | en_US |
dc.identifier.email | Luk, HW:wkluka@hkucc.hku.hk | en_US |
dc.identifier.authority | Chow, TW=rp00009 | en_US |
dc.identifier.authority | Luk, HW=rp00008 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.pmid | 12121608 | - |
dc.identifier.scopus | eid_2-s2.0-0036367728 | en_US |
dc.identifier.hkuros | 73292 | - |
dc.identifier.volume | 4 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.spage | 88 | en_US |
dc.identifier.epage | 92 | en_US |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.scopusauthorid | Wat, PY=6603286778 | en_US |
dc.identifier.scopusauthorid | Chow, TW=7203012369 | en_US |
dc.identifier.scopusauthorid | Luk, HW=7006636056 | en_US |
dc.identifier.scopusauthorid | Comfort, MB=7003605684 | en_US |
dc.identifier.issnl | 1523-0899 | - |