File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Clinical features of 46 eyes with calcified hydrogel intraocular lenses

TitleClinical features of 46 eyes with calcified hydrogel intraocular lenses
Authors
Issue Date2001
PublisherElsevier Inc. The Journal's web site is located at http://www.elsevier.com/locate/jcrs
Citation
Journal Of Cataract And Refractive Surgery, 2001, v. 27 n. 10, p. 1596-1606 How to Cite?
AbstractPurpose: To clarify the clinical features of delayed calcification of hydrogel intraocular lenses (IOLs) based on observation of a large case series. Setting: Ophthalmology department of 2 university teaching hospitals, Hong Kong, China. Methods: The first 44 patients with a known diagnosis of calcified IOL were recruited. Medical and ophthalmic histories were obtained. Surgical details, surgical complications, and visual acuity before and after IOL implantation were also retrieved. Patients then had a visual acuity test, a slitlamp examination of the features of the IOL calcification, and a fundus examination for clarity of view. Results: Forty-six eyes of 44 patients had IOL calcification. All had a Hydroview IOL. The onset was from 4 to 26 months after surgery. Ninety-three percent of eyes had generalized IOL calcification, and 96% had forceps marks on the IOL. Mean visual acuity deteriorated from 0.4 at 3 months to 0.13 at 19 months. Visual loss was more severe in patients with diabetes mellitus or ischemic heart disease and in those in which the IOL calcified earlier after implantation. Conclusion: All cases of IOL calcification were delayed in onset. The presence of forceps marks may provide a clue to the pathogenesis. Bilateral but asymmetric involvement in 2 patients suggests that the IOL was involved in the pathogenesis. Affected patients lost an average of 2.8 Snellen lines of visual acuity. Some eyes progressed more rapidly; however, the modulating factors remain unknown. © 2001 ASCRS and ESCRS.
Persistent Identifierhttp://hdl.handle.net/10722/87657
ISSN
2023 Impact Factor: 2.6
2023 SCImago Journal Rankings: 1.472
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorYu, AKFen_HK
dc.contributor.authorKwan, KYWen_HK
dc.contributor.authorChan, DHYen_HK
dc.contributor.authorFong, DYTen_HK
dc.date.accessioned2010-09-06T09:32:39Z-
dc.date.available2010-09-06T09:32:39Z-
dc.date.issued2001en_HK
dc.identifier.citationJournal Of Cataract And Refractive Surgery, 2001, v. 27 n. 10, p. 1596-1606en_HK
dc.identifier.issn0886-3350en_HK
dc.identifier.urihttp://hdl.handle.net/10722/87657-
dc.description.abstractPurpose: To clarify the clinical features of delayed calcification of hydrogel intraocular lenses (IOLs) based on observation of a large case series. Setting: Ophthalmology department of 2 university teaching hospitals, Hong Kong, China. Methods: The first 44 patients with a known diagnosis of calcified IOL were recruited. Medical and ophthalmic histories were obtained. Surgical details, surgical complications, and visual acuity before and after IOL implantation were also retrieved. Patients then had a visual acuity test, a slitlamp examination of the features of the IOL calcification, and a fundus examination for clarity of view. Results: Forty-six eyes of 44 patients had IOL calcification. All had a Hydroview IOL. The onset was from 4 to 26 months after surgery. Ninety-three percent of eyes had generalized IOL calcification, and 96% had forceps marks on the IOL. Mean visual acuity deteriorated from 0.4 at 3 months to 0.13 at 19 months. Visual loss was more severe in patients with diabetes mellitus or ischemic heart disease and in those in which the IOL calcified earlier after implantation. Conclusion: All cases of IOL calcification were delayed in onset. The presence of forceps marks may provide a clue to the pathogenesis. Bilateral but asymmetric involvement in 2 patients suggests that the IOL was involved in the pathogenesis. Affected patients lost an average of 2.8 Snellen lines of visual acuity. Some eyes progressed more rapidly; however, the modulating factors remain unknown. © 2001 ASCRS and ESCRS.en_HK
dc.languageengen_HK
dc.publisherElsevier Inc. The Journal's web site is located at http://www.elsevier.com/locate/jcrsen_HK
dc.relation.ispartofJournal of Cataract and Refractive Surgeryen_HK
dc.rightsJournal of Cataract & Refractive Surgery. Copyright © Elsevier Inc.en_HK
dc.titleClinical features of 46 eyes with calcified hydrogel intraocular lensesen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0886-3350&volume=27&issue=10&spage=1596&epage=606&date=2001&atitle=Clinical+features+of+46+eyes+with+calcified+hydrogel+intraocular+lensesen_HK
dc.identifier.emailFong, DYT: dytfong@hku.hken_HK
dc.identifier.authorityFong, DYT=rp00253en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0886-3350(01)01038-0en_HK
dc.identifier.pmid11687358-
dc.identifier.scopuseid_2-s2.0-0034767074en_HK
dc.identifier.hkuros65481en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034767074&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume27en_HK
dc.identifier.issue10en_HK
dc.identifier.spage1596en_HK
dc.identifier.epage1606en_HK
dc.identifier.isiWOS:000171785900020-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridYu, AKF=7401478701en_HK
dc.identifier.scopusauthoridKwan, KYW=7006405810en_HK
dc.identifier.scopusauthoridChan, DHY=15736955600en_HK
dc.identifier.scopusauthoridFong, DYT=35261710300en_HK
dc.identifier.issnl0886-3350-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats