File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Endometrial and subendometrial blood flow measured during early luteal phase by three-dimensional power Doppler ultrasound in excessive ovarian responders

TitleEndometrial and subendometrial blood flow measured during early luteal phase by three-dimensional power Doppler ultrasound in excessive ovarian responders
Authors
KeywordsEndometrial and subendometrial blood flow
Excessive responders
Three-dimensional power Doppler
Issue Date2004
PublisherOxford University Press. The Journal's web site is located at http://humrep.oxfordjournals.org/
Citation
Human Reproduction, 2004, v. 19 n. 4, p. 924-931 How to Cite?
AbstractBackground: Impaired implantation in assisted reproduction cycles with high serum estradiol (E2) concentrations may be related to suboptimal endometrial perfusion. Endometrial and subendometrial blood flow were compared between excessive responders (serum E2 on the day of HCG >20 000 pmol/l) and moderate responders (E2 ≤20 000 pmol/l). Methods: Three-dimensional (3D) ultrasound examination with power Doppler was performed 2, 4 and 7 days after HCG in 32 patients who did not have embryo transfer in order to measure endometrial thickness, pulsatility index (PI)/resistance index (RI) of uterine vessels, and endometrial volume, vascularization index (VI)/flow index (FI)/vascularization flow index (VFI) of endometrial and subendometrial regions. Results: Excessive responders tended to have lower endometrial and subendometrial VI/VFI on HCG +2 and more absent endometrial/subendometrial blood flow. They had significantly higher endometrial FI and subendometrial VFI than moderate responders on HCG +7. Only in the excessive responder group, uterine PI/RI declined significantly from HCG +2 to HCG +7 and endometrial VI/VFI increased significantly from HCG +4 to HCG +7. Conclusion: Changes in uterine Doppler flow indices, and endometrial and subendometrial 3D power Doppler flow indices during the early luteal phase were significantly different between moderate and excessive responders. © European Society of Human Reproduction and Embryology 2004; all rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/87128
ISSN
2023 Impact Factor: 6.0
2023 SCImago Journal Rankings: 1.852
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorNg, EHYen_HK
dc.contributor.authorChan, CCWen_HK
dc.contributor.authorTang, OSen_HK
dc.contributor.authorYeung, WSBen_HK
dc.contributor.authorHo, PCen_HK
dc.date.accessioned2010-09-06T09:25:41Z-
dc.date.available2010-09-06T09:25:41Z-
dc.date.issued2004en_HK
dc.identifier.citationHuman Reproduction, 2004, v. 19 n. 4, p. 924-931en_HK
dc.identifier.issn0268-1161en_HK
dc.identifier.urihttp://hdl.handle.net/10722/87128-
dc.description.abstractBackground: Impaired implantation in assisted reproduction cycles with high serum estradiol (E2) concentrations may be related to suboptimal endometrial perfusion. Endometrial and subendometrial blood flow were compared between excessive responders (serum E2 on the day of HCG >20 000 pmol/l) and moderate responders (E2 ≤20 000 pmol/l). Methods: Three-dimensional (3D) ultrasound examination with power Doppler was performed 2, 4 and 7 days after HCG in 32 patients who did not have embryo transfer in order to measure endometrial thickness, pulsatility index (PI)/resistance index (RI) of uterine vessels, and endometrial volume, vascularization index (VI)/flow index (FI)/vascularization flow index (VFI) of endometrial and subendometrial regions. Results: Excessive responders tended to have lower endometrial and subendometrial VI/VFI on HCG +2 and more absent endometrial/subendometrial blood flow. They had significantly higher endometrial FI and subendometrial VFI than moderate responders on HCG +7. Only in the excessive responder group, uterine PI/RI declined significantly from HCG +2 to HCG +7 and endometrial VI/VFI increased significantly from HCG +4 to HCG +7. Conclusion: Changes in uterine Doppler flow indices, and endometrial and subendometrial 3D power Doppler flow indices during the early luteal phase were significantly different between moderate and excessive responders. © European Society of Human Reproduction and Embryology 2004; all rights reserved.en_HK
dc.languageengen_HK
dc.publisherOxford University Press. The Journal's web site is located at http://humrep.oxfordjournals.org/en_HK
dc.relation.ispartofHuman Reproductionen_HK
dc.rightsHuman Reproduction. Copyright © Oxford University Press.en_HK
dc.subjectEndometrial and subendometrial blood flowen_HK
dc.subjectExcessive respondersen_HK
dc.subjectThree-dimensional power Doppleren_HK
dc.titleEndometrial and subendometrial blood flow measured during early luteal phase by three-dimensional power Doppler ultrasound in excessive ovarian respondersen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0268-1161&volume=19&issue=4&spage=924&epage=931&date=2004&atitle=Endometrial+and+subendometrial+blood+flow+measured+during+early+luteal+phase+by+three-dimensional+power+Doppler+ultrasound+in+excessive+ovarian+respondersen_HK
dc.identifier.emailNg, EHY:nghye@hkucc.hku.hken_HK
dc.identifier.emailYeung, WSB:wsbyeung@hkucc.hku.hken_HK
dc.identifier.emailHo, PC:pcho@hku.hken_HK
dc.identifier.authorityNg, EHY=rp00426en_HK
dc.identifier.authorityYeung, WSB=rp00331en_HK
dc.identifier.authorityHo, PC=rp00325en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1093/humrep/deh205en_HK
dc.identifier.pmid15016770-
dc.identifier.scopuseid_2-s2.0-1842740386en_HK
dc.identifier.hkuros87742en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-1842740386&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume19en_HK
dc.identifier.issue4en_HK
dc.identifier.spage924en_HK
dc.identifier.epage931en_HK
dc.identifier.isiWOS:000220486800026-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridNg, EHY=35238184300en_HK
dc.identifier.scopusauthoridChan, CCW=26643394500en_HK
dc.identifier.scopusauthoridTang, OS=36881248500en_HK
dc.identifier.scopusauthoridYeung, WSB=7102370745en_HK
dc.identifier.scopusauthoridHo, PC=7402211440en_HK
dc.identifier.issnl0268-1161-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats