File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: Placement optimization of cyber-physical digital microfluidic biochips

TitlePlacement optimization of cyber-physical digital microfluidic biochips
Authors
Issue Date2016
Citation
Proceedings - 2016 IEEE Biomedical Circuits and Systems Conference, BioCAS 2016, 2016, p. 448-451 How to Cite?
AbstractDigital microfluidic biochips maximize the possibilities in modern healthcare applications, such as point-of-care (POC) tests and immunoassays. Because of the error-prone biochemical experiments, cyber-physical digital microfluidic biochips with sensor integration is essential. However, the correctness of bioassays is closely related to the actuating times of electrodes, which should be taken care of during the module placement stage. Moreover, sensor constraint in sensor planning should also be considered to avoid sensing errors. This paper presents the first module and sensor co-placement algorithm of cyber-physical digital microfluidic biochips while considering the sensor constraint and minimizing the actuating times of electrodes. The experimental results show that we can effectively minimize the bioassay completion time and satisfy the sensor constraint.
Persistent Identifierhttp://hdl.handle.net/10722/336172

 

DC FieldValueLanguage
dc.contributor.authorKuo, Chun Hao-
dc.contributor.authorLu, Guan Ruei-
dc.contributor.authorHo, Tsung Yi-
dc.contributor.authorChen, Hung Ming-
dc.contributor.authorHu, Shiyan-
dc.date.accessioned2024-01-15T08:24:09Z-
dc.date.available2024-01-15T08:24:09Z-
dc.date.issued2016-
dc.identifier.citationProceedings - 2016 IEEE Biomedical Circuits and Systems Conference, BioCAS 2016, 2016, p. 448-451-
dc.identifier.urihttp://hdl.handle.net/10722/336172-
dc.description.abstractDigital microfluidic biochips maximize the possibilities in modern healthcare applications, such as point-of-care (POC) tests and immunoassays. Because of the error-prone biochemical experiments, cyber-physical digital microfluidic biochips with sensor integration is essential. However, the correctness of bioassays is closely related to the actuating times of electrodes, which should be taken care of during the module placement stage. Moreover, sensor constraint in sensor planning should also be considered to avoid sensing errors. This paper presents the first module and sensor co-placement algorithm of cyber-physical digital microfluidic biochips while considering the sensor constraint and minimizing the actuating times of electrodes. The experimental results show that we can effectively minimize the bioassay completion time and satisfy the sensor constraint.-
dc.languageeng-
dc.relation.ispartofProceedings - 2016 IEEE Biomedical Circuits and Systems Conference, BioCAS 2016-
dc.titlePlacement optimization of cyber-physical digital microfluidic biochips-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1109/BioCAS.2016.7833828-
dc.identifier.scopuseid_2-s2.0-85014165271-
dc.identifier.spage448-
dc.identifier.epage451-

Export via OAI-PMH Interface in XML Formats