File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Appears in Collections:
Conference Paper: Minimize the Power of Variable-Rate Gradient Pulse Using Conjugated Gradient Algorithm
Title | Minimize the Power of Variable-Rate Gradient Pulse Using Conjugated Gradient Algorithm |
---|---|
Authors | |
Issue Date | 2007 |
Publisher | International Society for Magnetic Resonance in Medicine |
Citation | Joint Annual Meeting ISMRM-ESMRMB SMRT16th Annual Meeting, Berlin, Germany, 19-25 May 2007, Abstract no. 3304 How to Cite? |
Abstract | When RF pulse is applied most RF power is deposited into the imaging object. Therefore, Variable-Rate Gradient (VRG) pulse has been widely used in
excitation to reduce the RF power. However, it is important to determine the variable gradient shape. In this work, Conjugated Gradient (CG) accompanied
by piecewise cubic spline interpolation is applied to optimize the gradient of the VRG pulse in order to minimize the RF power without changing of
excitation profile. Simulation results show that the RF power is reduced by 28% in excitation pulse. |
Persistent Identifier | http://hdl.handle.net/10722/99399 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pang, Y | en_HK |
dc.contributor.author | Liu, GZ | en_HK |
dc.contributor.author | Wei, J | en_HK |
dc.contributor.author | Shen, GG | en_HK |
dc.date.accessioned | 2010-09-25T18:28:27Z | - |
dc.date.available | 2010-09-25T18:28:27Z | - |
dc.date.issued | 2007 | en_HK |
dc.identifier.citation | Joint Annual Meeting ISMRM-ESMRMB SMRT16th Annual Meeting, Berlin, Germany, 19-25 May 2007, Abstract no. 3304 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/99399 | - |
dc.description.abstract | When RF pulse is applied most RF power is deposited into the imaging object. Therefore, Variable-Rate Gradient (VRG) pulse has been widely used in excitation to reduce the RF power. However, it is important to determine the variable gradient shape. In this work, Conjugated Gradient (CG) accompanied by piecewise cubic spline interpolation is applied to optimize the gradient of the VRG pulse in order to minimize the RF power without changing of excitation profile. Simulation results show that the RF power is reduced by 28% in excitation pulse. | - |
dc.language | eng | en_HK |
dc.publisher | International Society for Magnetic Resonance in Medicine | - |
dc.relation.ispartof | Joint Annual Meeting ISMRM-ESMRMB SMRT | en_HK |
dc.title | Minimize the Power of Variable-Rate Gradient Pulse Using Conjugated Gradient Algorithm | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.email | Shen, GG: gxshen@eee.hku.hk | en_HK |
dc.identifier.authority | Shen, GG=rp00166 | en_HK |
dc.identifier.hkuros | 132689 | en_HK |
dc.identifier.spage | 3304 | en_HK |