File Download
Supplementary
-
Citations:
- Appears in Collections:
Conference Paper: Optimization of HTS Tape Coil Design
Title | Optimization of HTS Tape Coil Design |
---|---|
Authors | |
Issue Date | 2004 |
Publisher | The International Society for Magnetic Resonance in Medicine (ISMRM) |
Citation | The International Society for Magnetic Resonance in Medicine (ISMRM) 12th Scientific Meeting & Exhibition, Kyoto, Japan, 15-21 May 2004. In Proceedings of the International Society for Magnetic Resonance in Medicine (ISMRM), 2004, v. 11, p. 1579 How to Cite? |
Abstract | HTS tapes are promising materials for RF coil due to their advantages of easier fabrication, easier frequency adjustment and lower cost over HTS films. A
theoretical model was developed to investigate the relationship of Q with coil size, solder joint and resonant frequency. The model showed that Q increased
with size and frequency. The model would be helpful in coil design to increase Q and hence increase SNR. Bi (2223) tape coils with different sizes and
resonant frequencies were fabricated to verify the theoretical model. |
Persistent Identifier | http://hdl.handle.net/10722/99370 |
ISSN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yuan, J | en_HK |
dc.contributor.author | Wang, C | en_HK |
dc.contributor.author | Shen, GG | en_HK |
dc.date.accessioned | 2010-09-25T18:27:10Z | - |
dc.date.available | 2010-09-25T18:27:10Z | - |
dc.date.issued | 2004 | en_HK |
dc.identifier.citation | The International Society for Magnetic Resonance in Medicine (ISMRM) 12th Scientific Meeting & Exhibition, Kyoto, Japan, 15-21 May 2004. In Proceedings of the International Society for Magnetic Resonance in Medicine (ISMRM), 2004, v. 11, p. 1579 | en_HK |
dc.identifier.issn | 1545-4436 | - |
dc.identifier.uri | http://hdl.handle.net/10722/99370 | - |
dc.description.abstract | HTS tapes are promising materials for RF coil due to their advantages of easier fabrication, easier frequency adjustment and lower cost over HTS films. A theoretical model was developed to investigate the relationship of Q with coil size, solder joint and resonant frequency. The model showed that Q increased with size and frequency. The model would be helpful in coil design to increase Q and hence increase SNR. Bi (2223) tape coils with different sizes and resonant frequencies were fabricated to verify the theoretical model. | - |
dc.language | eng | en_HK |
dc.publisher | The International Society for Magnetic Resonance in Medicine (ISMRM) | en_HK |
dc.relation.ispartof | Proceedings of the International Society for Magnetic Resonance in Medicine (ISMRM) | en_HK |
dc.title | Optimization of HTS Tape Coil Design | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.email | Shen, GG: gxshen@eee.hku.hk | en_HK |
dc.identifier.authority | Shen, GG=rp00166 | en_HK |
dc.description.nature | published_or_final_version | - |
dc.identifier.hkuros | 91311 | en_HK |
dc.identifier.volume | 11 | en_HK |
dc.identifier.spage | 1579 | en_HK |
dc.identifier.issnl | 1524-6965 | - |