TitleSimulation Study of Kurtosis Measurements in MR Diffusion Kurtosis Imaging
Authors
Issue Date2008
PublisherInternational Society of Magnetic Resonance in Medicine
Citation
International Society of Magnetic Resonance in Medicine (ISMRM) 16th Scientific Meeting and Exhibition, Toronto, Canada, 3-9 May 2008, p. 3330 How to Cite?
AbstractMonte Carlo simulation was performed in 1D space to study the spin diffusion, kurtosis characteristics, spin dephasing and MR signal attenuation in compartment-restricted diffusion environment. The apparent kurtosis was computed based on DKI formulation and compared to the true kurtosis and calculated from the actual diffusion displacement profiles. The simple results revealed that errors can be present in estimating true diffusion kurtosis by the apparent kurtosis. Choices of diffusion weighting parameters affect the outcomes. Both apparent diffusion kurtosis measurement and true diffusion kurtosis are not entirely intrinsic to the tissue structures because they also depend on the MR parameters. Therefore, cautions must be taken in the quantitative interpretation of kurtosis measurements in DKI experiments.
Persistent Identifierhttp://hdl.handle.net/10722/98887

 

DC FieldValueLanguage
dc.contributor.authorCheng, KHen_HK
dc.contributor.authorWu, EXen_HK
dc.date.accessioned2010-09-25T18:06:28Z-
dc.date.available2010-09-25T18:06:28Z-
dc.date.issued2008en_HK
dc.identifier.citationInternational Society of Magnetic Resonance in Medicine (ISMRM) 16th Scientific Meeting and Exhibition, Toronto, Canada, 3-9 May 2008, p. 3330en_HK
dc.identifier.urihttp://hdl.handle.net/10722/98887-
dc.description.abstractMonte Carlo simulation was performed in 1D space to study the spin diffusion, kurtosis characteristics, spin dephasing and MR signal attenuation in compartment-restricted diffusion environment. The apparent kurtosis was computed based on DKI formulation and compared to the true kurtosis and calculated from the actual diffusion displacement profiles. The simple results revealed that errors can be present in estimating true diffusion kurtosis by the apparent kurtosis. Choices of diffusion weighting parameters affect the outcomes. Both apparent diffusion kurtosis measurement and true diffusion kurtosis are not entirely intrinsic to the tissue structures because they also depend on the MR parameters. Therefore, cautions must be taken in the quantitative interpretation of kurtosis measurements in DKI experiments.-
dc.languageengen_HK
dc.publisherInternational Society of Magnetic Resonance in Medicine-
dc.relation.ispartof2008 Proceedings of International Society of Magnetic Resonance in Medicineen_HK
dc.titleSimulation Study of Kurtosis Measurements in MR Diffusion Kurtosis Imagingen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailWu, EX: ewu@eee.hku.hken_HK
dc.identifier.authorityWu, EX=rp00193en_HK
dc.identifier.hkuros141581en_HK
dc.identifier.spage3330en_HK

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats