File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1117/12.599877
- Scopus: eid_2-s2.0-25144452503
- Find via
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: Development of specifications for an integrated piezoelectric wafer active sensors system
Title | Development of specifications for an integrated piezoelectric wafer active sensors system |
---|---|
Authors | |
Keywords | Cracks Damage Detection Envelope Extraction, Nondestructive Evaluation Lamb Waves Nde Piezoelectric Piezoelectric Wafer Active Sensor Pwas Shm Structural Health Monitoring Ultrasonic |
Issue Date | 2005 |
Publisher | S P I E - International Society for Optical Engineering. The Journal's web site is located at http://www.spie.org/app/Publications/index.cfm?fuseaction=proceedings |
Citation | SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring, San Diego, CA, 7-10 March 2005. In Proceedings of SPIE - The International Society for Optical Engineering, 2005, v. 5764, p. 509-521 How to Cite? |
Abstract | This paper describes work performed in the development of a set of specification for the construction of an integrated electronic system for piezoelectric wafer active sensor (PWAS). The paper starts with a comprehensive review of the PWAS material properties, dimensions, and electrical characteristics. PWAS of various shapes and sizes are considered. Two boundary conditions were examined: free PWAS and PWAS attached to actual structures. For both, the PWAS immittance and the allowable dc and ac voltages were considered. The predicted values were compared with measurements performed over a wide frequency range (10 kHz to 2 MHz). Next, the electronic-equipment specifications were considered. The PWAS can be used in a number of different ways to actively detect damage in structures. Our aim was to develop electronic-equipment specifications that would extract the optimum performance from the PWAS, i.e., maximize the coupling with the structure and obtain large-amplitude Lamb wave transmission and reception. Analytical predictions were compared with measurements made using current laboratory equipment. The comparative analysis revealed that the current electronic equipment does not fully exploit the PWAS capabilities. Hence, the PWAS equipment specifications were divided into two categories: "existing" and "desired". The former category designates integrated electronic equipment that would offer the same PWAS performance as the existing lab equipment, but be of a lower volume/weight/cost. The latter category refers to advanced electronic equipment that will exploit the full potential of PWAS transducers while being of lower volume/weight/cost than the lab equipment. Both categories are presented and discussed in the paper. |
Persistent Identifier | http://hdl.handle.net/10722/91086 |
ISSN | 2023 SCImago Journal Rankings: 0.152 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jenkins, C | en_HK |
dc.contributor.author | Giurgiutiu, V | en_HK |
dc.contributor.author | Lin, B | en_HK |
dc.contributor.author | Liu, W | en_HK |
dc.date.accessioned | 2010-09-17T10:12:49Z | - |
dc.date.available | 2010-09-17T10:12:49Z | - |
dc.date.issued | 2005 | en_HK |
dc.identifier.citation | SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring, San Diego, CA, 7-10 March 2005. In Proceedings of SPIE - The International Society for Optical Engineering, 2005, v. 5764, p. 509-521 | en_HK |
dc.identifier.issn | 0277-786X | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/91086 | - |
dc.description.abstract | This paper describes work performed in the development of a set of specification for the construction of an integrated electronic system for piezoelectric wafer active sensor (PWAS). The paper starts with a comprehensive review of the PWAS material properties, dimensions, and electrical characteristics. PWAS of various shapes and sizes are considered. Two boundary conditions were examined: free PWAS and PWAS attached to actual structures. For both, the PWAS immittance and the allowable dc and ac voltages were considered. The predicted values were compared with measurements performed over a wide frequency range (10 kHz to 2 MHz). Next, the electronic-equipment specifications were considered. The PWAS can be used in a number of different ways to actively detect damage in structures. Our aim was to develop electronic-equipment specifications that would extract the optimum performance from the PWAS, i.e., maximize the coupling with the structure and obtain large-amplitude Lamb wave transmission and reception. Analytical predictions were compared with measurements made using current laboratory equipment. The comparative analysis revealed that the current electronic equipment does not fully exploit the PWAS capabilities. Hence, the PWAS equipment specifications were divided into two categories: "existing" and "desired". The former category designates integrated electronic equipment that would offer the same PWAS performance as the existing lab equipment, but be of a lower volume/weight/cost. The latter category refers to advanced electronic equipment that will exploit the full potential of PWAS transducers while being of lower volume/weight/cost than the lab equipment. Both categories are presented and discussed in the paper. | en_HK |
dc.language | eng | en_HK |
dc.publisher | S P I E - International Society for Optical Engineering. The Journal's web site is located at http://www.spie.org/app/Publications/index.cfm?fuseaction=proceedings | en_HK |
dc.relation.ispartof | Proceedings of SPIE - The International Society for Optical Engineering | en_HK |
dc.subject | Cracks | en_HK |
dc.subject | Damage Detection | en_HK |
dc.subject | Envelope Extraction, Nondestructive Evaluation | en_HK |
dc.subject | Lamb Waves | en_HK |
dc.subject | Nde | en_HK |
dc.subject | Piezoelectric | en_HK |
dc.subject | Piezoelectric Wafer Active Sensor | en_HK |
dc.subject | Pwas | en_HK |
dc.subject | Shm | en_HK |
dc.subject | Structural Health Monitoring | en_HK |
dc.subject | Ultrasonic | en_HK |
dc.title | Development of specifications for an integrated piezoelectric wafer active sensors system | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.email | Lin, B:blin@hku.hk | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1117/12.599877 | en_HK |
dc.identifier.scopus | eid_2-s2.0-25144452503 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-25144452503&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 5764 | en_HK |
dc.identifier.spage | 509 | en_HK |
dc.identifier.epage | 521 | en_HK |
dc.identifier.issnl | 0277-786X | - |