Article: Avoiding retinal slippage during macular translocation surgery with 360 retinotomy

TitleAvoiding retinal slippage during macular translocation surgery with 360 retinotomy
Authors
KeywordsMacular translocation surgery
Perfluorocarbon air exchange
Perfluorocarbon fluid
Retinal slippage
Silicone oil
Issue Date2008
PublisherSpringer Verlag. The Journal's web site is located at http://link.springer.de/link/service/journals/00417/index.htm
Citation
Graefe's Archive For Clinical And Experimental Ophthalmology, 2008, v. 246 n. 5, p. 649-651 How to Cite?
AbstractPurpose: To describe a surgical technique to avoid retinal slippage. Method: An audit was carried out on a consecutive series of 75 consecutive cases of macular translocation for age-related macular degeneration (MT360). We encountered two cases of slippage, which led to a change in technique. Result: No further cases of slippage were encountered. We were able to perform an exchange of perfluorocarbon liquid with air or directly with silicone oil. Discussion: Retinal slippage is caused by the presence of aqueous in the infusion tubing. Meticulous removal of all aqueous from the infusion system and vitreous cavity can eliminate this complication. © Springer-Verlag 2007.
Persistent Identifierhttp://hdl.handle.net/10722/85499
ISSN
2023 Impact Factor: 2.4
2023 SCImago Journal Rankings: 1.014
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLi, KKWen_HK
dc.contributor.authorWong, Den_HK
dc.date.accessioned2010-09-06T09:05:48Z-
dc.date.available2010-09-06T09:05:48Z-
dc.date.issued2008en_HK
dc.identifier.citationGraefe's Archive For Clinical And Experimental Ophthalmology, 2008, v. 246 n. 5, p. 649-651en_HK
dc.identifier.issn0721-832Xen_HK
dc.identifier.urihttp://hdl.handle.net/10722/85499-
dc.description.abstractPurpose: To describe a surgical technique to avoid retinal slippage. Method: An audit was carried out on a consecutive series of 75 consecutive cases of macular translocation for age-related macular degeneration (MT360). We encountered two cases of slippage, which led to a change in technique. Result: No further cases of slippage were encountered. We were able to perform an exchange of perfluorocarbon liquid with air or directly with silicone oil. Discussion: Retinal slippage is caused by the presence of aqueous in the infusion tubing. Meticulous removal of all aqueous from the infusion system and vitreous cavity can eliminate this complication. © Springer-Verlag 2007.en_HK
dc.languageengen_HK
dc.publisherSpringer Verlag. The Journal's web site is located at http://link.springer.de/link/service/journals/00417/index.htmen_HK
dc.relation.ispartofGraefe's Archive for Clinical and Experimental Ophthalmologyen_HK
dc.rightsThe original publication is available at www.springerlink.com-
dc.subjectMacular translocation surgeryen_HK
dc.subjectPerfluorocarbon air exchangeen_HK
dc.subjectPerfluorocarbon fluiden_HK
dc.subjectRetinal slippageen_HK
dc.subjectSilicone oilen_HK
dc.subject.meshFluorocarbons - administration and dosage-
dc.subject.meshIntraoperative Complications - prevention and control-
dc.subject.meshMacula Lutea - transplantation-
dc.subject.meshRetinal Diseases - surgery-
dc.subject.meshSilicone Oils - administration and dosage-
dc.titleAvoiding retinal slippage during macular translocation surgery with 360 retinotomyen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0721-832X&volume=246&issue=5&spage=649&epage=651&date=2008&atitle=Avoiding+retinal+slippage+during+macular+translocation+surgery+with+360+retinotomyen_HK
dc.identifier.emailWong, D: shdwong@hku.hken_HK
dc.identifier.authorityWong, D=rp00516en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1007/s00417-007-0677-3en_HK
dc.identifier.pmid18004588en_HK
dc.identifier.scopuseid_2-s2.0-42049084048en_HK
dc.identifier.hkuros144366en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-42049084048&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume246en_HK
dc.identifier.issue5en_HK
dc.identifier.spage649en_HK
dc.identifier.epage651en_HK
dc.identifier.isiWOS:000254773300004-
dc.publisher.placeGermanyen_HK
dc.identifier.scopusauthoridLi, KKW=7404990010en_HK
dc.identifier.scopusauthoridWong, D=7401536078en_HK
dc.identifier.citeulike2772236-
dc.identifier.issnl0721-832X-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats