File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Occupational hearing loss: Screening with distortion-product otoacoustic emissions

TitleOccupational hearing loss: Screening with distortion-product otoacoustic emissions
Authors
KeywordsHearing screening
Occupational hearing loss
Otoacoustic emissions
Issue Date2004
PublisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/14992027.asp
Citation
International Journal Of Audiology, 2004, v. 43 n. 6, p. 323-329 How to Cite?
AbstractHearing assessment of applicants for occupational hearing loss compensation can be a time-consuming process. An accurate screening procedure that is sensitive to occupational hearing loss may have application in many situations. The present study developed distortin-product otoacoustic emission (DPOAE) screening criteria to identify subjects likely to meet the Hong Kong requirements for occupational hearing loss compensation, namely a bilateral sensorineural loss ≥ 40 dB HL (average of 1000, 2000 and 3000 Hz). The screening criteria of 1500 and/ or 2000 Hz, with a signal-to-noise ratio of >0 of 3 dB, yielded high sensitivity and specificity. DPOAE measures therefore have the potential to accurately indicate possible occupational hearing loss. However DPOAEs should be used as a screening tool only, as conventional pure-tone audiometry remains the more comprehensive measure of hearing sensitivity.
Persistent Identifierhttp://hdl.handle.net/10722/85283
ISSN
2021 Impact Factor: 2.437
2020 SCImago Journal Rankings: 0.832
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorChan, VSWen_HK
dc.contributor.authorWong, ECMen_HK
dc.contributor.authorMcPherson, Ben_HK
dc.date.accessioned2010-09-06T09:02:57Z-
dc.date.available2010-09-06T09:02:57Z-
dc.date.issued2004en_HK
dc.identifier.citationInternational Journal Of Audiology, 2004, v. 43 n. 6, p. 323-329en_HK
dc.identifier.issn1499-2027en_HK
dc.identifier.urihttp://hdl.handle.net/10722/85283-
dc.description.abstractHearing assessment of applicants for occupational hearing loss compensation can be a time-consuming process. An accurate screening procedure that is sensitive to occupational hearing loss may have application in many situations. The present study developed distortin-product otoacoustic emission (DPOAE) screening criteria to identify subjects likely to meet the Hong Kong requirements for occupational hearing loss compensation, namely a bilateral sensorineural loss ≥ 40 dB HL (average of 1000, 2000 and 3000 Hz). The screening criteria of 1500 and/ or 2000 Hz, with a signal-to-noise ratio of >0 of 3 dB, yielded high sensitivity and specificity. DPOAE measures therefore have the potential to accurately indicate possible occupational hearing loss. However DPOAEs should be used as a screening tool only, as conventional pure-tone audiometry remains the more comprehensive measure of hearing sensitivity.en_HK
dc.languageengen_HK
dc.publisherInforma Healthcare. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/14992027.aspen_HK
dc.relation.ispartofInternational Journal of Audiologyen_HK
dc.rightsInternational Journal of Audiology. Copyright © Informa Healthcare.en_HK
dc.subjectHearing screeningen_HK
dc.subjectOccupational hearing lossen_HK
dc.subjectOtoacoustic emissionsen_HK
dc.titleOccupational hearing loss: Screening with distortion-product otoacoustic emissionsen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1499-2027&volume=43&spage=323&epage=329&date=2004&atitle=Occupational+Hearing+Loss:+Screening+with+Distortion-product+Otoacoustic+Emissionsen_HK
dc.identifier.emailMcPherson, B: dbmcpher@hkucc.hku.hken_HK
dc.identifier.authorityMcPherson, B=rp00937en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1080/14992020400050041en_HK
dc.identifier.pmid15457814-
dc.identifier.scopuseid_2-s2.0-3042682377en_HK
dc.identifier.hkuros90610en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-3042682377&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume43en_HK
dc.identifier.issue6en_HK
dc.identifier.spage323en_HK
dc.identifier.epage329en_HK
dc.identifier.isiWOS:000221985000002-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridChan, VSW=7202654979en_HK
dc.identifier.scopusauthoridWong, ECM=7403161535en_HK
dc.identifier.scopusauthoridMcPherson, B=7006800770en_HK
dc.identifier.issnl1499-2027-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats