Citation | Annals of the College of Surgeons of Hong Kong, 2000, v. 4 n. 2, p. 69-72 How to Cite? |
Abstract | Carotid duplex scanning is a non-invasive, cost-effective method for the diagnosis of stability, progression or improvement of extracranial cerebral disease. It yields functional information that complements the anatomic information provided by angiography. It can localize the disease with B-mode ultrasound and can determine the functional severity of the disease with spectral analysis and colour-flow imaging. The diagnostic criteria are based on the peak systolic velocity and end diastolic velocity of the internal carotid artery. Carotid stenosis of 70% or greater is taken as significant. The texture and morphology of the plaque can be reported as either homogeneous, heterogeneous with ulceration or heterogeneous without ulceration. This distinction would not be detected readily by angiography. With a high degree of accuracy in identifying sig-nificant stenoses in carotid arteries, duplex scanning can replace angiography prior to performing carotid endarterectomy. |
Persistent Identifier | http://hdl.handle.net/10722/83837 |
ISSN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wu, LLH | en_HK |
dc.contributor.author | Ting, ACW | en_HK |
dc.contributor.author | Cheng, SWK | en_HK |
dc.date.accessioned | 2010-09-06T08:45:49Z | - |
dc.date.available | 2010-09-06T08:45:49Z | - |
dc.date.issued | 2000 | en_HK |
dc.identifier.citation | Annals of the College of Surgeons of Hong Kong, 2000, v. 4 n. 2, p. 69-72 | en_HK |
dc.identifier.issn | 1028-4001 | - |
dc.identifier.uri | http://hdl.handle.net/10722/83837 | - |
dc.description.abstract | Carotid duplex scanning is a non-invasive, cost-effective method for the diagnosis of stability, progression or improvement of extracranial cerebral disease. It yields functional information that complements the anatomic information provided by angiography. It can localize the disease with B-mode ultrasound and can determine the functional severity of the disease with spectral analysis and colour-flow imaging. The diagnostic criteria are based on the peak systolic velocity and end diastolic velocity of the internal carotid artery. Carotid stenosis of 70% or greater is taken as significant. The texture and morphology of the plaque can be reported as either homogeneous, heterogeneous with ulceration or heterogeneous without ulceration. This distinction would not be detected readily by angiography. With a high degree of accuracy in identifying sig-nificant stenoses in carotid arteries, duplex scanning can replace angiography prior to performing carotid endarterectomy. | - |
dc.language | eng | en_HK |
dc.publisher | Blackwell Publishing Asia. The Journal's web site is located at http://www.blackwellpublishing.com/journals/ASH | - |
dc.relation.ispartof | Annals of the College of Surgeons of Hong Kong | en_HK |
dc.rights | The definitive version is available at www.blackwell-synergy.com | - |
dc.subject | Angiography | - |
dc.subject | Carotid duplex scanning | - |
dc.subject | Carotid stenosis | - |
dc.subject | Plaque | - |
dc.title | Experience in colour-flow duplex carotid imaging for extracranial carotid stenosis | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Ting, ACW: tingacw@hkucc.hku.hk | en_HK |
dc.identifier.email | Cheng, SWK: wkcheng@hkucc.hku.hk | en_HK |
dc.identifier.authority | Cheng, SWK=rp00374 | en_HK |
dc.identifier.doi | 10.1046/j.1442-2034.2000.00054.x | - |
dc.identifier.hkuros | 48483 | en_HK |
dc.identifier.volume | 4 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 69 | - |
dc.identifier.epage | 72 | - |
dc.publisher.place | Australia | - |
dc.identifier.issnl | 1028-4001 | - |