File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1007/s00268-001-0112-6
- Scopus: eid_2-s2.0-0034795989
- PMID: 11596892
- WOS: WOS:000171328100012
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Endoscopic stenting for malignant biliary obstruction
Title | Endoscopic stenting for malignant biliary obstruction |
---|---|
Authors | |
Issue Date | 2001 |
Publisher | Springer New York LLC. The Journal's web site is located at http://link.springer.de/link/service/journals/00268/ |
Citation | World Journal Of Surgery, 2001, v. 25 n. 10, p. 1289-1295 How to Cite? |
Abstract | Use of endoscopic stents to manage patients with malignant obstructive jaundice is a well accepted measure. Interpretation of the results of endoscopic stenting must be made with reference to the level of the bile duct obstruction. Results were generally unsatisfactory for hilar lesions, especially when the intrahepatic ducts were segregated into multiple isolated systems. After deployment, stent dysfunction due to clogging by biliary sludge is apparently an inevitable process for the conventional plastic stent. Considerable efforts had been made to prolong the stent patency by changing its physical configuration, coating the inner lumen, and the choice of material but with little success. The development of a self-expandable metal stent is a major advance, but the benefits derived from a larger stent lumen are compromised by the initial expense and the tumor ingrowth through the wires for all models available commercially. Current data failed to substantiate the value of routine preoperative biliary decompression, as there is no reduction in the morbidity and mortality rates after surgery. Although biased patient selection may have resulted in the negative observations made, repeated clinical trials should probably focus on patients with distal bile duct tumors who are preparing for a major pancreatic resection. As a definitive palliative measure, endoscopic stenting is a more cost-effective option than surgery for patients with limited life expectancy based on data regarding plastic stents. The recommendations are evolving however, as there is progressive refinement of laparoscopic surgery techniques and designs of endoscopic stents. |
Persistent Identifier | http://hdl.handle.net/10722/83709 |
ISSN | 2023 Impact Factor: 2.3 2023 SCImago Journal Rankings: 0.772 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lai, ECS | en_HK |
dc.contributor.author | Lo, CM | en_HK |
dc.contributor.author | Liu, CL | en_HK |
dc.date.accessioned | 2010-09-06T08:44:17Z | - |
dc.date.available | 2010-09-06T08:44:17Z | - |
dc.date.issued | 2001 | en_HK |
dc.identifier.citation | World Journal Of Surgery, 2001, v. 25 n. 10, p. 1289-1295 | en_HK |
dc.identifier.issn | 0364-2313 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/83709 | - |
dc.description.abstract | Use of endoscopic stents to manage patients with malignant obstructive jaundice is a well accepted measure. Interpretation of the results of endoscopic stenting must be made with reference to the level of the bile duct obstruction. Results were generally unsatisfactory for hilar lesions, especially when the intrahepatic ducts were segregated into multiple isolated systems. After deployment, stent dysfunction due to clogging by biliary sludge is apparently an inevitable process for the conventional plastic stent. Considerable efforts had been made to prolong the stent patency by changing its physical configuration, coating the inner lumen, and the choice of material but with little success. The development of a self-expandable metal stent is a major advance, but the benefits derived from a larger stent lumen are compromised by the initial expense and the tumor ingrowth through the wires for all models available commercially. Current data failed to substantiate the value of routine preoperative biliary decompression, as there is no reduction in the morbidity and mortality rates after surgery. Although biased patient selection may have resulted in the negative observations made, repeated clinical trials should probably focus on patients with distal bile duct tumors who are preparing for a major pancreatic resection. As a definitive palliative measure, endoscopic stenting is a more cost-effective option than surgery for patients with limited life expectancy based on data regarding plastic stents. The recommendations are evolving however, as there is progressive refinement of laparoscopic surgery techniques and designs of endoscopic stents. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Springer New York LLC. The Journal's web site is located at http://link.springer.de/link/service/journals/00268/ | en_HK |
dc.relation.ispartof | World Journal of Surgery | en_HK |
dc.title | Endoscopic stenting for malignant biliary obstruction | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0364-2313&volume=25&spage=1289&epage=1295&date=2001&atitle=Endoscopic+stenting+for+malignant+biliary+obstruction | en_HK |
dc.identifier.email | Lo, CM: chungmlo@hkucc.hku.hk | en_HK |
dc.identifier.authority | Lo, CM=rp00412 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1007/s00268-001-0112-6 | en_HK |
dc.identifier.pmid | 11596892 | - |
dc.identifier.scopus | eid_2-s2.0-0034795989 | en_HK |
dc.identifier.hkuros | 71358 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0034795989&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 25 | en_HK |
dc.identifier.issue | 10 | en_HK |
dc.identifier.spage | 1289 | en_HK |
dc.identifier.epage | 1295 | en_HK |
dc.identifier.isi | WOS:000171328100012 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Lai, ECS=36932159600 | en_HK |
dc.identifier.scopusauthorid | Lo, CM=7401771672 | en_HK |
dc.identifier.scopusauthorid | Liu, CL=15850672800 | en_HK |
dc.identifier.issnl | 0364-2313 | - |