File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1007/s00167-008-0550-x
- Scopus: eid_2-s2.0-46149118422
- PMID: 18478202
- WOS: WOS:000257227800009
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Cutting errors in total knee replacement: Assessment by computer assisted surgery
Title | Cutting errors in total knee replacement: Assessment by computer assisted surgery |
---|---|
Authors | |
Keywords | Cutting error Total knee replacement |
Issue Date | 2008 |
Publisher | Springer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/167 |
Citation | Knee Surgery, Sports Traumatology, Arthroscopy, 2008, v. 16 n. 7, p. 670-673 How to Cite? |
Abstract | The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in 40 consecutive total knee replacements was reported. All the operations were done by the same surgeon. The amount of cutting error was measured by the use of computer navigation system. It was hypothesized that there was no difference in the amount of error between bone cut through the cutting slot (slotted cutting) and bone cut done on the surface of the cutting guide (open cutting). It was found that the average absolute cutting error was 1° in the coronal plane and 1.4° in the sagittal plane. Significantly more outlier (more than 3°) was observed in the errors in the sagittal plane (P = 0.014, chi square test). Open cutting resulted in less error in the sagittal plane of the tibial cut when compared with slotted cutting (P = 0.031, Mann-Whitney U Test). This was attributed by the use of a thicker saw blade with higher stiffness in the open cutting method. © 2008 Springer-Verlag. |
Persistent Identifier | http://hdl.handle.net/10722/79662 |
ISSN | 2023 Impact Factor: 3.3 2023 SCImago Journal Rankings: 1.785 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yau, WP | en_HK |
dc.contributor.author | Chiu, KY | en_HK |
dc.date.accessioned | 2010-09-06T07:57:10Z | - |
dc.date.available | 2010-09-06T07:57:10Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Knee Surgery, Sports Traumatology, Arthroscopy, 2008, v. 16 n. 7, p. 670-673 | en_HK |
dc.identifier.issn | 0942-2056 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/79662 | - |
dc.description.abstract | The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in 40 consecutive total knee replacements was reported. All the operations were done by the same surgeon. The amount of cutting error was measured by the use of computer navigation system. It was hypothesized that there was no difference in the amount of error between bone cut through the cutting slot (slotted cutting) and bone cut done on the surface of the cutting guide (open cutting). It was found that the average absolute cutting error was 1° in the coronal plane and 1.4° in the sagittal plane. Significantly more outlier (more than 3°) was observed in the errors in the sagittal plane (P = 0.014, chi square test). Open cutting resulted in less error in the sagittal plane of the tibial cut when compared with slotted cutting (P = 0.031, Mann-Whitney U Test). This was attributed by the use of a thicker saw blade with higher stiffness in the open cutting method. © 2008 Springer-Verlag. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Springer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/167 | en_HK |
dc.relation.ispartof | Knee Surgery, Sports Traumatology, Arthroscopy | en_HK |
dc.rights | The original publication is available at www.springerlink.com | - |
dc.subject | Cutting error | en_HK |
dc.subject | Total knee replacement | en_HK |
dc.subject.mesh | Arthritis, Rheumatoid - surgery | - |
dc.subject.mesh | Arthroplasty, Replacement, Knee - adverse effects | - |
dc.subject.mesh | Medical Errors - statistics and numerical data | - |
dc.subject.mesh | Osteoarthritis, Knee - surgery | - |
dc.subject.mesh | Osteotomy - adverse effects | - |
dc.title | Cutting errors in total knee replacement: Assessment by computer assisted surgery | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0942-2056&volume=16&issue=7&spage=670&epage=673&date=2008&atitle=Cutting+errors+in+total+knee+replacement:+assessment+by+computer+assisted+surgery. | en_HK |
dc.identifier.email | Yau, WP:peterwpy@hkucc.hku.hk | en_HK |
dc.identifier.email | Chiu, KY:pkychiu@hkucc.hku.hk | en_HK |
dc.identifier.authority | Yau, WP=rp00500 | en_HK |
dc.identifier.authority | Chiu, KY=rp00379 | en_HK |
dc.description.nature | postprint | - |
dc.identifier.doi | 10.1007/s00167-008-0550-x | en_HK |
dc.identifier.pmid | 18478202 | - |
dc.identifier.scopus | eid_2-s2.0-46149118422 | en_HK |
dc.identifier.hkuros | 142876 | en_HK |
dc.identifier.hkuros | 146358 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-46149118422&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 16 | en_HK |
dc.identifier.issue | 7 | en_HK |
dc.identifier.spage | 670 | en_HK |
dc.identifier.epage | 673 | en_HK |
dc.identifier.isi | WOS:000257227800009 | - |
dc.publisher.place | Germany | en_HK |
dc.identifier.scopusauthorid | Yau, WP=7005822441 | en_HK |
dc.identifier.scopusauthorid | Chiu, KY=7202988127 | en_HK |
dc.identifier.citeulike | 3095343 | - |
dc.identifier.issnl | 0942-2056 | - |