File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
  • Find via Find It@HKUL
Supplementary

Article: A cadaveric model for biomechanical study on fixation methods for distal radius fracture of AO Type C3

TitleA cadaveric model for biomechanical study on fixation methods for distal radius fracture of AO Type C3
AO C3型橈骨遠端骨折固定方法研究的生物力學模型
Authors
KeywordsDistal radius fracture (橈骨遠端骨折)
Treatment (治療)
Biomechanics (生物力學)
Issue Date2002
PublisherZhonghua chuang shang gu ke za zhi bian ji wei yuan hui (中華創傷骨科雜誌編輯部). The Journal's web site is located at http://www.cjot.org/
Citation
Chinese Journal of Orthopaedic Trauma, 2002, v. 4 n. 4, p. 282-284 How to Cite?
中華創傷骨科雜誌, 2002, v. 4 n. 4, p. 282-284 How to Cite?
AbstractObjective To design a cadaveric model for AO type C3 fracture of distal radius and to evaluate the axial load transmission pattern on the model fixed with dorsal plating. Methods A cadaveric model for biomechanical study on fixation methods for AO type C3 fractures of distal radius was designed and produced, and its efficacy was assessed. Results 100N axial load was found to produce only a 1 to 2mm axial shortening in the intact specimen, and the deformation was elastic. The axial load transmission through intact radius was 83.82 %of the total distal axial load. A model of uniform AO type C3 distal radius fracture was successfully created in seven cadaveric forearms. After fixation of the fracture with dorsal plating, axial load transmission through radius was 75.64 %of the total distal axial load. Conclusion A standardized AO type C3 fracture of distal radius can be reproduced with good reproducibility of the setup and results of this model. The results suggest that dorsal plating can not totally restore the axial loading transmission pattern of normal radius with 100N axial load. 目的設計一個C3型橈骨遠端骨折尸骨模型并評估其有效性。方法設計并制作一個C3型橈骨遠端骨折尸骨模型,并用其評估背側鋼板固定橈骨遠端骨折的生物力學特性。結果在完整標本上100N縱向負荷僅使橈骨產生1~2mm彈性變,其中橈骨傳遞83.82%的負荷。在7具標本上成功制作C3型橈骨遠端骨折模型,用背側鋼板固定骨折后,發現橈骨傳遞75.64%的負荷。結論本研究成功制作可重復性好的C3型橈骨遠端骨折尸骨模型,生物力學測試提示在100N縱向負荷下,背側鋼板固定不能完全重建橈骨遠端骨折的力學性能。
Persistent Identifierhttp://hdl.handle.net/10722/79605
ISSN
2023 SCImago Journal Rankings: 0.164

 

DC FieldValueLanguage
dc.contributor.authorZhu, L-
dc.contributor.authorHo, H-
dc.contributor.authorLu, W-
dc.contributor.authorLeung, KL-
dc.contributor.authorChow, SP-
dc.date.accessioned2010-09-06T07:56:32Z-
dc.date.available2010-09-06T07:56:32Z-
dc.date.issued2002-
dc.identifier.citationChinese Journal of Orthopaedic Trauma, 2002, v. 4 n. 4, p. 282-284-
dc.identifier.citation中華創傷骨科雜誌, 2002, v. 4 n. 4, p. 282-284-
dc.identifier.issn1671-7600-
dc.identifier.urihttp://hdl.handle.net/10722/79605-
dc.description.abstractObjective To design a cadaveric model for AO type C3 fracture of distal radius and to evaluate the axial load transmission pattern on the model fixed with dorsal plating. Methods A cadaveric model for biomechanical study on fixation methods for AO type C3 fractures of distal radius was designed and produced, and its efficacy was assessed. Results 100N axial load was found to produce only a 1 to 2mm axial shortening in the intact specimen, and the deformation was elastic. The axial load transmission through intact radius was 83.82 %of the total distal axial load. A model of uniform AO type C3 distal radius fracture was successfully created in seven cadaveric forearms. After fixation of the fracture with dorsal plating, axial load transmission through radius was 75.64 %of the total distal axial load. Conclusion A standardized AO type C3 fracture of distal radius can be reproduced with good reproducibility of the setup and results of this model. The results suggest that dorsal plating can not totally restore the axial loading transmission pattern of normal radius with 100N axial load. 目的設計一個C3型橈骨遠端骨折尸骨模型并評估其有效性。方法設計并制作一個C3型橈骨遠端骨折尸骨模型,并用其評估背側鋼板固定橈骨遠端骨折的生物力學特性。結果在完整標本上100N縱向負荷僅使橈骨產生1~2mm彈性變,其中橈骨傳遞83.82%的負荷。在7具標本上成功制作C3型橈骨遠端骨折模型,用背側鋼板固定骨折后,發現橈骨傳遞75.64%的負荷。結論本研究成功制作可重復性好的C3型橈骨遠端骨折尸骨模型,生物力學測試提示在100N縱向負荷下,背側鋼板固定不能完全重建橈骨遠端骨折的力學性能。-
dc.languagechi-
dc.publisherZhonghua chuang shang gu ke za zhi bian ji wei yuan hui (中華創傷骨科雜誌編輯部). The Journal's web site is located at http://www.cjot.org/-
dc.relation.ispartofChinese Journal of Orthopaedic Trauma-
dc.relation.ispartof中華創傷骨科雜誌-
dc.subjectDistal radius fracture (橈骨遠端骨折)-
dc.subjectTreatment (治療)-
dc.subjectBiomechanics (生物力學)-
dc.titleA cadaveric model for biomechanical study on fixation methods for distal radius fracture of AO Type C3-
dc.titleAO C3型橈骨遠端骨折固定方法研究的生物力學模型-
dc.typeArticle-
dc.identifier.emailLu, W: wwlu@hkusua.hku.hk-
dc.identifier.emailLeung, KL: klleunga@HKUCC.hku.hk-
dc.identifier.emailChow, SP: spchow@hkucc.hku.hk-
dc.identifier.authorityLu, W=rp00411-
dc.identifier.authorityLeung, KL=rp00297-
dc.identifier.authorityChow, SP=rp00064-
dc.identifier.hkuros79252-
dc.identifier.volume4-
dc.identifier.issue4-
dc.identifier.spage282-
dc.identifier.epage284-
dc.publisher.placeGuangzhou (廣州)-
dc.identifier.issnl1671-7600-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats