File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Limitation of long-term atrial pacing via floating ring electrode using overlapping biphasic impulse stimulation in ambulatory-paced patients

TitleLimitation of long-term atrial pacing via floating ring electrode using overlapping biphasic impulse stimulation in ambulatory-paced patients
Authors
Issue Date1998
PublisherExcerpta Medica, Inc.. The Journal's web site is located at http://www.ajconline.org/
Citation
American Journal Of Cardiology, 1998, v. 81 n. 5, p. 645-647 How to Cite?
AbstractLong-term atrial pacing with overlapping biphasic impulse stimulation using floating atrial electrodes is limited in its use by the high rate of intermittent failure to capture the atrium and by the occurrence of diaphragmatic stimulation in ambulatory patients.
Persistent Identifierhttp://hdl.handle.net/10722/78291
ISSN
2023 Impact Factor: 2.3
2023 SCImago Journal Rankings: 0.950
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorTse, HFen_HK
dc.contributor.authorLau, CPen_HK
dc.contributor.authorLeung, SKen_HK
dc.date.accessioned2010-09-06T07:41:15Z-
dc.date.available2010-09-06T07:41:15Z-
dc.date.issued1998en_HK
dc.identifier.citationAmerican Journal Of Cardiology, 1998, v. 81 n. 5, p. 645-647en_HK
dc.identifier.issn0002-9149en_HK
dc.identifier.urihttp://hdl.handle.net/10722/78291-
dc.description.abstractLong-term atrial pacing with overlapping biphasic impulse stimulation using floating atrial electrodes is limited in its use by the high rate of intermittent failure to capture the atrium and by the occurrence of diaphragmatic stimulation in ambulatory patients.en_HK
dc.languageengen_HK
dc.publisherExcerpta Medica, Inc.. The Journal's web site is located at http://www.ajconline.org/en_HK
dc.relation.ispartofAmerican Journal of Cardiologyen_HK
dc.subject.meshAgeden_HK
dc.subject.meshCardiac Pacing, Artificial - methodsen_HK
dc.subject.meshElectric Stimulation - methodsen_HK
dc.subject.meshElectrodes, Implanteden_HK
dc.subject.meshEvaluation Studies as Topicen_HK
dc.subject.meshFemaleen_HK
dc.subject.meshHeart Block - therapyen_HK
dc.subject.meshHumansen_HK
dc.subject.meshMaleen_HK
dc.subject.meshTime Factorsen_HK
dc.titleLimitation of long-term atrial pacing via floating ring electrode using overlapping biphasic impulse stimulation in ambulatory-paced patientsen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0002-9149&volume=81&spage=645&epage=647&date=1998&atitle=Limitation+of+long-term+atrial+pacing+via+floating+ring+electrode+using+overlapping+biphasic+impulse+stimulation+in+ambulatory-paced+patientsen_HK
dc.identifier.emailTse, HF:hftse@hkucc.hku.hken_HK
dc.identifier.authorityTse, HF=rp00428en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0002-9149(97)00988-0en_HK
dc.identifier.pmid9514468-
dc.identifier.scopuseid_2-s2.0-0032032666en_HK
dc.identifier.hkuros39375en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0032032666&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume81en_HK
dc.identifier.issue5en_HK
dc.identifier.spage645en_HK
dc.identifier.epage647en_HK
dc.identifier.isiWOS:000072413300024-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridTse, HF=7006070805en_HK
dc.identifier.scopusauthoridLau, CP=7401968501en_HK
dc.identifier.scopusauthoridLeung, SK=7202044902en_HK
dc.identifier.issnl0002-9149-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats