File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1046/j.1460-9592.2003.00014.x
- Scopus: eid_2-s2.0-0037247636
- PMID: 12687810
- WOS: WOS:000181906600014
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing
Title | Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing |
---|---|
Authors | |
Keywords | Atrioventricular interval Cardiac output Congestive heart failure Echocardiography Impedance cardiography |
Issue Date | 2003 |
Publisher | Wiley-Blackwell Publishing, Inc. The Journal's web site is located at http://www.wiley.com/bw/journal.asp?ref=0147-8389&site=1 |
Citation | Pace - Pacing And Clinical Electrophysiology, 2003, v. 26 n. 1 II, p. 189-191 How to Cite? |
Abstract | Left ventricular (LV) pacing is increasingly used in the management of congestive heart failure. Optimization of the atrioventricular (AV) interval is essential to maximize the hemodynamic benefits of this therapy. Although Doppler echocardiography (echo) is the most widely used method, it is time-consuming, expensive, and operator-dependent. We examined the value of an impedance cardiography (IC)-based method of cardiac output (CO) measurement to optimize the AV interval in 5 men and 1 woman (mean age = 72 ± 11 years) during permanent LV pacing with a 4.8 Fr unipolar coronary sinus pacing lead. Simultaneous measurements of CO by IC and echo were performed at AV intervals of 50, 80, 110, 150, 180, and 225 ms during DDD pacing at 85 beats/min. The optimal AV interval varied between 110 and 180 ms. In 5 of 6 patients (83%), the optimal AV interval by echo and IC was identical. While CO measurements were higher with IC than with echo (6.1 ± 0.4L/min vs 4.7 ± 0.3 L/min, P < 0.05), CO measurements by IC and echo were closely correlated r = 0.67, P < 0.001). In conclusion, our initial experience suggests that IC is a reliable method of AV interval optimization during LV pacing. IC and echo measurements of CO during LV pacing were closely correlated. |
Persistent Identifier | http://hdl.handle.net/10722/77830 |
ISSN | 2023 Impact Factor: 1.7 2023 SCImago Journal Rankings: 0.579 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Tse, HF | en_HK |
dc.contributor.author | Yu, C | en_HK |
dc.contributor.author | Park, E | en_HK |
dc.contributor.author | Lau, CP | en_HK |
dc.date.accessioned | 2010-09-06T07:36:13Z | - |
dc.date.available | 2010-09-06T07:36:13Z | - |
dc.date.issued | 2003 | en_HK |
dc.identifier.citation | Pace - Pacing And Clinical Electrophysiology, 2003, v. 26 n. 1 II, p. 189-191 | en_HK |
dc.identifier.issn | 0147-8389 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/77830 | - |
dc.description.abstract | Left ventricular (LV) pacing is increasingly used in the management of congestive heart failure. Optimization of the atrioventricular (AV) interval is essential to maximize the hemodynamic benefits of this therapy. Although Doppler echocardiography (echo) is the most widely used method, it is time-consuming, expensive, and operator-dependent. We examined the value of an impedance cardiography (IC)-based method of cardiac output (CO) measurement to optimize the AV interval in 5 men and 1 woman (mean age = 72 ± 11 years) during permanent LV pacing with a 4.8 Fr unipolar coronary sinus pacing lead. Simultaneous measurements of CO by IC and echo were performed at AV intervals of 50, 80, 110, 150, 180, and 225 ms during DDD pacing at 85 beats/min. The optimal AV interval varied between 110 and 180 ms. In 5 of 6 patients (83%), the optimal AV interval by echo and IC was identical. While CO measurements were higher with IC than with echo (6.1 ± 0.4L/min vs 4.7 ± 0.3 L/min, P < 0.05), CO measurements by IC and echo were closely correlated r = 0.67, P < 0.001). In conclusion, our initial experience suggests that IC is a reliable method of AV interval optimization during LV pacing. IC and echo measurements of CO during LV pacing were closely correlated. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Wiley-Blackwell Publishing, Inc. The Journal's web site is located at http://www.wiley.com/bw/journal.asp?ref=0147-8389&site=1 | en_HK |
dc.relation.ispartof | PACE - Pacing and Clinical Electrophysiology | en_HK |
dc.subject | Atrioventricular interval | - |
dc.subject | Cardiac output | - |
dc.subject | Congestive heart failure | - |
dc.subject | Echocardiography | - |
dc.subject | Impedance cardiography | - |
dc.subject.mesh | Aged | en_HK |
dc.subject.mesh | Atrioventricular Node - physiopathology | en_HK |
dc.subject.mesh | Cardiac Output | en_HK |
dc.subject.mesh | Cardiac Pacing, Artificial - methods | en_HK |
dc.subject.mesh | Cardiography, Impedance | en_HK |
dc.subject.mesh | Echocardiography, Doppler | en_HK |
dc.subject.mesh | Female | en_HK |
dc.subject.mesh | Humans | en_HK |
dc.subject.mesh | Male | en_HK |
dc.subject.mesh | Sick Sinus Syndrome - therapy - ultrasonography | en_HK |
dc.title | Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0147-8389&volume=26 &issue=1 Pt 2&spage=189&epage=91&date=2003&atitle=Impedance+Cardiography+for+Atrioventricular+Interval+Optimization+During+Permanent+Left+Ventricular+Pacing. | en_HK |
dc.identifier.email | Tse, HF:hftse@hkucc.hku.hk | en_HK |
dc.identifier.authority | Tse, HF=rp00428 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1046/j.1460-9592.2003.00014.x | - |
dc.identifier.pmid | 12687810 | - |
dc.identifier.scopus | eid_2-s2.0-0037247636 | en_HK |
dc.identifier.hkuros | 81647 | en_HK |
dc.identifier.hkuros | 100804 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0037247636&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 26 | en_HK |
dc.identifier.issue | 1 II | en_HK |
dc.identifier.spage | 189 | en_HK |
dc.identifier.epage | 191 | en_HK |
dc.identifier.isi | WOS:000181906600014 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Tse, HF=7006070805 | en_HK |
dc.identifier.scopusauthorid | Yu, C=7404978038 | en_HK |
dc.identifier.scopusauthorid | Park, E=7402224798 | en_HK |
dc.identifier.scopusauthorid | Lau, CP=7401968501 | en_HK |
dc.identifier.issnl | 0147-8389 | - |