File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Transient stability index of power systems based on theory of stability region and its applications

TitleTransient stability index of power systems based on theory of stability region and its applications
Authors
KeywordsContingency ranking
Critical clearing-time
Quadratic approximation
Stability region
Transient stability index
Issue Date2006
Citation
Dianli Xitong Zidonghua/Automation Of Electric Power Systems, 2006, v. 30 n. 8, p. 1-6+26 How to Cite?
AbstractThis paper presents a new transient stability index based on the implicit expression for the stability region boundary and an approximation of the proposed index based on the quadratic approximation of the stability region. The proposed index may have no constraints such as the existence of Lyapunov-type energy function. Two applications, calculating the critical clearing time and contingency ranking, are presented based on the approximated index. The critical clearing time is obtained by the quadratic equation that fits the relation between the transient stability index and clearing time. The contingency ranking results are obtained directly by comparing the values of the transient stability index of different contingencies. Simulations in IEEE 3-machine 9-bus system and 10 machine 39-bus New England system show the applicability of the proposed transient stability index.
Persistent Identifierhttp://hdl.handle.net/10722/73961
ISSN
2023 SCImago Journal Rankings: 1.171
ISI Accession Number IDCSCD:2409662
References

 

DC FieldValueLanguage
dc.contributor.authorXue, ACen_HK
dc.contributor.authorShen, Cen_HK
dc.contributor.authorMei, SWen_HK
dc.contributor.authorNi, YXen_HK
dc.contributor.authorWu, FFen_HK
dc.date.accessioned2010-09-06T06:56:26Z-
dc.date.available2010-09-06T06:56:26Z-
dc.date.issued2006en_HK
dc.identifier.citationDianli Xitong Zidonghua/Automation Of Electric Power Systems, 2006, v. 30 n. 8, p. 1-6+26en_HK
dc.identifier.issn1000-1026en_HK
dc.identifier.urihttp://hdl.handle.net/10722/73961-
dc.description.abstractThis paper presents a new transient stability index based on the implicit expression for the stability region boundary and an approximation of the proposed index based on the quadratic approximation of the stability region. The proposed index may have no constraints such as the existence of Lyapunov-type energy function. Two applications, calculating the critical clearing time and contingency ranking, are presented based on the approximated index. The critical clearing time is obtained by the quadratic equation that fits the relation between the transient stability index and clearing time. The contingency ranking results are obtained directly by comparing the values of the transient stability index of different contingencies. Simulations in IEEE 3-machine 9-bus system and 10 machine 39-bus New England system show the applicability of the proposed transient stability index.en_HK
dc.languageengen_HK
dc.relation.ispartofDianli Xitong Zidonghua/Automation of Electric Power Systemsen_HK
dc.subjectContingency rankingen_HK
dc.subjectCritical clearing-timeen_HK
dc.subjectQuadratic approximationen_HK
dc.subjectStability regionen_HK
dc.subjectTransient stability indexen_HK
dc.titleTransient stability index of power systems based on theory of stability region and its applicationsen_HK
dc.typeArticleen_HK
dc.identifier.emailNi, YX: yxni@eee.hku.hken_HK
dc.identifier.emailWu, FF: ffwu@eee.hku.hken_HK
dc.identifier.authorityNi, YX=rp00161en_HK
dc.identifier.authorityWu, FF=rp00194en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-33745154466en_HK
dc.identifier.hkuros120050en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33745154466&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume30en_HK
dc.identifier.issue8en_HK
dc.identifier.spage1en_HK
dc.identifier.epage6+26en_HK
dc.identifier.isiCSCD:2409662-
dc.publisher.placeChinaen_HK
dc.identifier.scopusauthoridXue, AC=7005988274en_HK
dc.identifier.scopusauthoridShen, C=7402859778en_HK
dc.identifier.scopusauthoridMei, SW=7102846252en_HK
dc.identifier.scopusauthoridNi, YX=7402910021en_HK
dc.identifier.scopusauthoridWu, FF=7403465107en_HK
dc.identifier.issnl1000-1026-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats