File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1002/cmr.b.20062
- Scopus: eid_2-s2.0-33646381123
- WOS: WOS:000236960000004
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Comparison of parallel imaging performance between planar strip arrays and surface loop arrays at high field based on simulation
Title | Comparison of parallel imaging performance between planar strip arrays and surface loop arrays at high field based on simulation |
---|---|
Authors | |
Keywords | Loop array Planar strip array Parallel imaging SNR;g-factor |
Issue Date | 2006 |
Publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www.wiley.com/WileyCDA/WileyTitle/productCd-CMRB.html |
Citation | Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2006, v. 29B n. 2, p. 84-94 How to Cite? |
Abstract | Parallel imaging performance of overlapped, nonoverlapped loop arrays, and planar strip arrays are investigated at 220 MHz quantitatively based on simulations with finite difference time domain (FDTD) method. Their signal-to-noise ratio (SNR) and geometry factors (g-factors) in different axial and coronal slices are compared. The average SNR of planar strip arrays is up to 6% better than loop coil arrays in the vicinity of coil array plane. The g-factors of planar strip arrays are significantly better when the acceleration factor approaches the number of array elements. Specifically, the four-channel planar strip array modeled in this work gains 46% improvement at acceleration factor four compared with its loop array counterpart. Based on the simulation at 220 MHz, it is demonstrated that planar strip arrays have better parallel imaging performance than loop arrays in the vicinity of the coil array and for high acceleration factors. © 2006 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 29B: 84–94, 2006. |
Persistent Identifier | http://hdl.handle.net/10722/73663 |
ISSN | 2023 Impact Factor: 0.9 2020 SCImago Journal Rankings: 0.286 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wei, J | - |
dc.contributor.author | Qu, P | - |
dc.contributor.author | Shen, GX | - |
dc.date.accessioned | 2010-09-06T06:53:33Z | - |
dc.date.available | 2010-09-06T06:53:33Z | - |
dc.date.issued | 2006 | - |
dc.identifier.citation | Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2006, v. 29B n. 2, p. 84-94 | - |
dc.identifier.issn | 1552-5031 | - |
dc.identifier.uri | http://hdl.handle.net/10722/73663 | - |
dc.description.abstract | Parallel imaging performance of overlapped, nonoverlapped loop arrays, and planar strip arrays are investigated at 220 MHz quantitatively based on simulations with finite difference time domain (FDTD) method. Their signal-to-noise ratio (SNR) and geometry factors (g-factors) in different axial and coronal slices are compared. The average SNR of planar strip arrays is up to 6% better than loop coil arrays in the vicinity of coil array plane. The g-factors of planar strip arrays are significantly better when the acceleration factor approaches the number of array elements. Specifically, the four-channel planar strip array modeled in this work gains 46% improvement at acceleration factor four compared with its loop array counterpart. Based on the simulation at 220 MHz, it is demonstrated that planar strip arrays have better parallel imaging performance than loop arrays in the vicinity of the coil array and for high acceleration factors. © 2006 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 29B: 84–94, 2006. | - |
dc.language | eng | - |
dc.publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www.wiley.com/WileyCDA/WileyTitle/productCd-CMRB.html | - |
dc.relation.ispartof | Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering | - |
dc.rights | Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. Copyright © John Wiley & Sons, Inc. | - |
dc.rights | Special Statement for Preprint only Before publication: 'This is a preprint of an article accepted for publication in [The Journal of Pathology] Copyright © ([year]) ([Pathological Society of Great Britain and Ireland])'. After publication: the preprint notice should be amended to follows: 'This is a preprint of an article published in [include the complete citation information for the final version of the Contribution as published in the print edition of the Journal]' For Cochrane Library/ Cochrane Database of Systematic Reviews, add statement & acknowledgement : ‘This review is published as a Cochrane Review in the Cochrane Database of Systematic Reviews 20XX, Issue X. Cochrane Reviews are regularly updated as new evidence emerges and in response to comments and criticisms, and the Cochrane Database of Systematic Reviews should be consulted for the most recent version of the Review.’ Please include reference to the Review and hyperlink to the original version using the following format e.g. Authors. Title of Review. Cochrane Database of Systematic Reviews 20XX, Issue #. Art. No.: CD00XXXX. DOI: 10.1002/14651858.CD00XXXX (insert persistent link to the article by using the URL: http://dx.doi.org/10.1002/14651858.CD00XXXX) (This statement should refer to the most recent issue of the Cochrane Database of Systematic Reviews in which the Review published.) | - |
dc.subject | Loop array | - |
dc.subject | Planar strip array | - |
dc.subject | Parallel imaging | - |
dc.subject | SNR;g-factor | - |
dc.title | Comparison of parallel imaging performance between planar strip arrays and surface loop arrays at high field based on simulation | - |
dc.type | Article | - |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1552-5031&volume=29B 2&spage=84&epage=94&date=2006&atitle=A+simulation-based+comparision+of+strip+line+coil+array+and+conventional+loop+array+for+High+Field+MRI | en_HK |
dc.identifier.email | Shen, GX: gxshen@eee.hku.hk | - |
dc.identifier.authority | Shen, GX=rp00166 | - |
dc.identifier.doi | 10.1002/cmr.b.20062 | - |
dc.identifier.scopus | eid_2-s2.0-33646381123 | - |
dc.identifier.hkuros | 121252 | - |
dc.identifier.volume | 29B | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 84 | - |
dc.identifier.epage | 94 | - |
dc.identifier.isi | WOS:000236960000004 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 1552-5031 | - |