File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Simultaneous determination of major, minor and trace elements in biocarbonates by inductively coupled plasma mass spectrometry

TitleSimultaneous determination of major, minor and trace elements in biocarbonates by inductively coupled plasma mass spectrometry
Authors
KeywordsBiocarbonates
Inductively coupled plasma mass spectrometry
Major elements
Minor elements
Multi-ratio
Trace elements
Issue Date2002
PublisherSpringer Verlag. The Journal's web site is located at http://link.springer.de/link/service/journals/00216/index.htm
Citation
Analytical And Bioanalytical Chemistry, 2002, v. 374 n. 7-8, p. 1338-1340 How to Cite?
AbstractA method was developed for simultaneous determination of major (Ca), minor (Mg and Sr) and trace (Ba and U) elements in biocarbonates by inductively coupled plasma mass spectrometry (ICP-MS). The method precision (RSD%) is 0.73% for Ca, 0.77% for Mg, 0.59% for Sr, 2.02% for Ba, 1.13% for U, 0.67% for Mg/Ca, 0.27% for Sr/Ca, 2.06% for Ba/Ca and 1.23% for U/Ca. The ratio precision suggests that ICP-MS is satisfactory for obtaining multi-ratio data from biocarbonates. This technique was applied to 67 continuous coral samples.
Persistent Identifierhttp://hdl.handle.net/10722/72958
ISSN
2021 Impact Factor: 4.478
2020 SCImago Journal Rankings: 0.860
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorSun, Yen_HK
dc.contributor.authorSun, Men_HK
dc.date.accessioned2010-09-06T06:46:43Z-
dc.date.available2010-09-06T06:46:43Z-
dc.date.issued2002en_HK
dc.identifier.citationAnalytical And Bioanalytical Chemistry, 2002, v. 374 n. 7-8, p. 1338-1340en_HK
dc.identifier.issn1618-2642en_HK
dc.identifier.urihttp://hdl.handle.net/10722/72958-
dc.description.abstractA method was developed for simultaneous determination of major (Ca), minor (Mg and Sr) and trace (Ba and U) elements in biocarbonates by inductively coupled plasma mass spectrometry (ICP-MS). The method precision (RSD%) is 0.73% for Ca, 0.77% for Mg, 0.59% for Sr, 2.02% for Ba, 1.13% for U, 0.67% for Mg/Ca, 0.27% for Sr/Ca, 2.06% for Ba/Ca and 1.23% for U/Ca. The ratio precision suggests that ICP-MS is satisfactory for obtaining multi-ratio data from biocarbonates. This technique was applied to 67 continuous coral samples.en_HK
dc.languageengen_HK
dc.publisherSpringer Verlag. The Journal's web site is located at http://link.springer.de/link/service/journals/00216/index.htmen_HK
dc.relation.ispartofAnalytical and Bioanalytical Chemistryen_HK
dc.subjectBiocarbonates-
dc.subjectInductively coupled plasma mass spectrometry-
dc.subjectMajor elements-
dc.subjectMinor elements-
dc.subjectMulti-ratio-
dc.subjectTrace elements-
dc.subject.meshAnimalsen_HK
dc.subject.meshAnthozoa - chemistryen_HK
dc.subject.meshCarbonates - chemistryen_HK
dc.subject.meshMass Spectrometry - methodsen_HK
dc.subject.meshMetals - analysisen_HK
dc.subject.meshSensitivity and Specificityen_HK
dc.subject.meshTime Factorsen_HK
dc.titleSimultaneous determination of major, minor and trace elements in biocarbonates by inductively coupled plasma mass spectrometryen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1618-2642&volume=374&spage=1338&epage=1340&date=2002&atitle=Simultaneous+determination+of+major,+minor+and+trace+elements+in+biocarbonates+by+inductively+coupled+plasma+mass+spectrometryen_HK
dc.identifier.emailSun, M:minsun@hku.hken_HK
dc.identifier.authoritySun, M=rp00780en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1007/s00216-002-1633-zen_HK
dc.identifier.pmid12474108-
dc.identifier.scopuseid_2-s2.0-0036460680en_HK
dc.identifier.hkuros81812en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0036460680&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume374en_HK
dc.identifier.issue7-8en_HK
dc.identifier.spage1338en_HK
dc.identifier.epage1340en_HK
dc.identifier.isiWOS:000180567200028-
dc.publisher.placeGermanyen_HK
dc.identifier.scopusauthoridSun, Y=7406433515en_HK
dc.identifier.scopusauthoridSun, M=25932315800en_HK
dc.identifier.issnl1618-2642-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats