Conference Paper: Comparison of SAAD and SAR procedures for equivalent dose determination using quartz
Title | Comparison of SAAD and SAR procedures for equivalent dose determination using quartz |
---|---|
Authors | |
Keywords | Equivalent dose Quartz SAAD and SAR |
Issue Date | 2003 |
Publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/radmeas |
Citation | The 10th international Conference on Luminescence and Electron-Spin Resonance Dating (LED 2002), Reno, NV., 24-28 June 2002. In Radiation Measurements, 2003, v. 37 n. 4-5, p. 417-424 How to Cite? |
Abstract | Comparisons between the single-aliquot additive-dose (SAAD) and single-aliquot regenerative-dose (SAR) procedures are made using 150-212 μm quartz grains separated from three sediment samples. Growth curves and equivalent doses from the two procedures are compared directly using single aliquots of quartz. With appropriate corrections for the loss of signals in our SAAD protocol, the SAAD and SAR growth curves coincide well. It is confirmed that the luminescence correction in the SAAD protocol can only be applied to samples for which the natural signal is in the linear part of the growth curve. A new correction method is proposed. © 2003 Elsevier Ltd. All rights reserved. |
Description | These journal issues entitled: Proceedings of the 10th international Conference on Luminescence and Electron-Spin Resonance Dating (LED 2002) |
Persistent Identifier | http://hdl.handle.net/10722/72722 |
ISSN | 2023 Impact Factor: 1.6 2023 SCImago Journal Rankings: 0.463 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhao, H | - |
dc.contributor.author | Li, SH | - |
dc.contributor.author | Murray, AS | - |
dc.date.accessioned | 2010-09-06T06:44:29Z | - |
dc.date.available | 2010-09-06T06:44:29Z | - |
dc.date.issued | 2003 | - |
dc.identifier.citation | The 10th international Conference on Luminescence and Electron-Spin Resonance Dating (LED 2002), Reno, NV., 24-28 June 2002. In Radiation Measurements, 2003, v. 37 n. 4-5, p. 417-424 | - |
dc.identifier.issn | 1350-4487 | - |
dc.identifier.uri | http://hdl.handle.net/10722/72722 | - |
dc.description | These journal issues entitled: Proceedings of the 10th international Conference on Luminescence and Electron-Spin Resonance Dating (LED 2002) | - |
dc.description.abstract | Comparisons between the single-aliquot additive-dose (SAAD) and single-aliquot regenerative-dose (SAR) procedures are made using 150-212 μm quartz grains separated from three sediment samples. Growth curves and equivalent doses from the two procedures are compared directly using single aliquots of quartz. With appropriate corrections for the loss of signals in our SAAD protocol, the SAAD and SAR growth curves coincide well. It is confirmed that the luminescence correction in the SAAD protocol can only be applied to samples for which the natural signal is in the linear part of the growth curve. A new correction method is proposed. © 2003 Elsevier Ltd. All rights reserved. | en_HK |
dc.language | eng | - |
dc.publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/radmeas | - |
dc.relation.ispartof | Radiation Measurements | - |
dc.rights | NOTICE: this is the author’s version of a work that was accepted for publication in [Journal title]. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, [VOL#, ISSUE#, (DATE)] DOI# | - |
dc.subject | Equivalent dose | en_HK |
dc.subject | Quartz | en_HK |
dc.subject | SAAD and SAR | en_HK |
dc.title | Comparison of SAAD and SAR procedures for equivalent dose determination using quartz | - |
dc.type | Conference_Paper | - |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1350-4487&volume=37&spage=417&epage=424&date=2003&atitle=Comparison+of+SAAD+and+SAR+procedures+for+equivalent+dose+determination+using+quartz | en_HK |
dc.identifier.email | Li, SH: shli@hku.hk | - |
dc.identifier.authority | Li, SH=rp00740 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S1350-4487(03)00019-2 | - |
dc.identifier.scopus | eid_2-s2.0-0038818633 | en_HK |
dc.identifier.hkuros | 71010 | - |
dc.identifier.hkuros | 82154 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0038818633&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 37 | - |
dc.identifier.issue | 4-5 | - |
dc.identifier.spage | 417 | - |
dc.identifier.epage | 424 | - |
dc.identifier.isi | WOS:000184110400020 | - |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | Zhao, H=7404778046 | en_HK |
dc.identifier.scopusauthorid | Li, SH=24438103700 | en_HK |
dc.identifier.scopusauthorid | Murray, AS=7401932735 | en_HK |
dc.customcontrol.immutable | sml 151009 - merged | - |
dc.identifier.issnl | 1350-4487 | - |