File Download
  Links for fulltext
     (May Require Subscription)
  • Find via Find It@HKUL
Supplementary

Article: Analyses of trace uranium of coral samples by ID-ICP-MS method and applications to high resolution U/Ca thermometer

TitleAnalyses of trace uranium of coral samples by ID-ICP-MS method and applications to high resolution U/Ca thermometer
珊瑚中微量铀的ID-ICP-MS 高精度测定及其在珊瑚U/Ca 温度计研究中的应用
Authors
KeywordsID-ICP-MS
珊瑚 (Coral)
U/Ca温度计 (U/Ca thermometer)
Issue Date1998
PublisherKe xue chu ban she.
Citation
Diqiu Huaxue, 1998, v. 27 n. 2, p. 125-131 How to Cite?
地球化学, 1998, 第27卷 第2期, pp. 125-131 How to Cite?
AbstractID-ICP-MS, an analytical method that combines isotope dilution technique and ICP-MS method had been developed in our laboratory. Trace uranium of the coral samples from the northern area of the South China Sea had been measured to an accuracy of 0.5%. Depended on these results, a high resolution coral U/Ca thermometer for thes area was established. Monthly average SSTs with a precision of ±0.5℃ were attainable by this U/Ca thermometer.
建立了同位素稀释技术与IC-MS 相结合的ID-ICP-MS 分析方法, 成功测量了取自南海北部的滨珊瑚样品中的微量铀, 获得0.5% 左右的精度。并以此建立南海北部近岸海域的珊瑚U/Ca 温度计, 其温度精度可达士0.5 ℃。
Persistent Identifierhttp://hdl.handle.net/10722/72551
ISSN

 

DC FieldValueLanguage
dc.contributor.authorWei, Gen_HK
dc.contributor.authorLi, XHen_HK
dc.contributor.authorLiu, HCen_HK
dc.contributor.authorSun, Men_HK
dc.date.accessioned2010-09-06T06:42:54Z-
dc.date.available2010-09-06T06:42:54Z-
dc.date.issued1998en_HK
dc.identifier.citationDiqiu Huaxue, 1998, v. 27 n. 2, p. 125-131en_HK
dc.identifier.citation地球化学, 1998, 第27卷 第2期, pp. 125-131-
dc.identifier.issn0379-1726en_HK
dc.identifier.urihttp://hdl.handle.net/10722/72551-
dc.description.abstractID-ICP-MS, an analytical method that combines isotope dilution technique and ICP-MS method had been developed in our laboratory. Trace uranium of the coral samples from the northern area of the South China Sea had been measured to an accuracy of 0.5%. Depended on these results, a high resolution coral U/Ca thermometer for thes area was established. Monthly average SSTs with a precision of ±0.5℃ were attainable by this U/Ca thermometer.-
dc.description.abstract建立了同位素稀释技术与IC-MS 相结合的ID-ICP-MS 分析方法, 成功测量了取自南海北部的滨珊瑚样品中的微量铀, 获得0.5% 左右的精度。并以此建立南海北部近岸海域的珊瑚U/Ca 温度计, 其温度精度可达士0.5 ℃。-
dc.languagechien_HK
dc.publisherKe xue chu ban she.en_HK
dc.relation.ispartofDiqiu Huaxueen_HK
dc.relation.ispartof地球化学-
dc.subjectID-ICP-MS-
dc.subject珊瑚 (Coral)-
dc.subjectU/Ca温度计 (U/Ca thermometer)-
dc.titleAnalyses of trace uranium of coral samples by ID-ICP-MS method and applications to high resolution U/Ca thermometeren_HK
dc.title珊瑚中微量铀的ID-ICP-MS 高精度测定及其在珊瑚U/Ca 温度计研究中的应用-
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0016-7037&volume=27&issue=2&spage=125&epage=131&date=1998&atitle=Analyses+of+trace+uranium+of+coral+samples+by+ID-ICP-MS+method+and+applications+to+high+resolution+U/Ca+thermometeren_HK
dc.identifier.emailWei, G: gjwei@gig.ac.cnen_HK
dc.identifier.emailSun, M: minsun@hku.hken_HK
dc.identifier.authoritySun, M=rp00780en_HK
dc.description.naturepublished_or_final_version-
dc.identifier.hkuros34191en_HK
dc.publisher.placeChina-
dc.identifier.issnl0379-1726-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats