Article: Interface of chip-based capillary electrophoresis-inductively coupled plasma-atomic emission spectrometry (CE-ICP-AES)
Title | Interface of chip-based capillary electrophoresis-inductively coupled plasma-atomic emission spectrometry (CE-ICP-AES) |
---|---|
Authors | |
Issue Date | 2006 |
Publisher | Royal Society of Chemistry. The Journal's web site is located at http://www.rsc.org/jaas |
Citation | Journal Of Analytical Atomic Spectrometry, 2006, v. 21 n. 2, p. 134-140 How to Cite? |
Abstract | An interface of chip-based capillary electrophoresis (CE)-inductively coupled plasma-atomic emission spectrometry (ICP-AES) that is based on cross-flow nebulization has been developed. A polydimethylsiloxane (PDMS) CE-chip with conventional cross channel layout was used. A stainless steel tube was placed orthogonal to the exit of the CE separation channel for cross flow nebulization. A supplementary flow of buffer solution at the channel exit was used to improve nebulization efficiency. Two capillaries were inserted into the CE chip near the inlet of the separation channel for sample and buffer solution injection. Syringe pumps were used to manipulate the flow rate and flow direction of the sample, buffer, and supplementary buffer solution. Peak broadening due to the shape (bulb and tube-shaped) and size of the spray chambers was studied. The smaller tube-shaped spray chamber was used because of smaller peak broadening effect due to aerosol transport. The nebulization and transport efficiency of the CE-ICP interface was approximately 10%. Ba 2+ and Mg 2+ ions were eluted from the CE-chip within 30 s. Resolution of the Ba 2+ and Mg 2+ peaks was 0.7 using the chip-based CE-ICP-AES system. © The Royal Society of Chemistry 2006. |
Persistent Identifier | http://hdl.handle.net/10722/69082 |
ISSN | 2023 Impact Factor: 3.1 2023 SCImago Journal Rankings: 0.722 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hui, AYN | en_HK |
dc.contributor.author | Wang, G | en_HK |
dc.contributor.author | Lin, B | en_HK |
dc.contributor.author | Chan, WT | en_HK |
dc.date.accessioned | 2010-09-06T06:10:24Z | - |
dc.date.available | 2010-09-06T06:10:24Z | - |
dc.date.issued | 2006 | en_HK |
dc.identifier.citation | Journal Of Analytical Atomic Spectrometry, 2006, v. 21 n. 2, p. 134-140 | en_HK |
dc.identifier.issn | 0267-9477 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/69082 | - |
dc.description.abstract | An interface of chip-based capillary electrophoresis (CE)-inductively coupled plasma-atomic emission spectrometry (ICP-AES) that is based on cross-flow nebulization has been developed. A polydimethylsiloxane (PDMS) CE-chip with conventional cross channel layout was used. A stainless steel tube was placed orthogonal to the exit of the CE separation channel for cross flow nebulization. A supplementary flow of buffer solution at the channel exit was used to improve nebulization efficiency. Two capillaries were inserted into the CE chip near the inlet of the separation channel for sample and buffer solution injection. Syringe pumps were used to manipulate the flow rate and flow direction of the sample, buffer, and supplementary buffer solution. Peak broadening due to the shape (bulb and tube-shaped) and size of the spray chambers was studied. The smaller tube-shaped spray chamber was used because of smaller peak broadening effect due to aerosol transport. The nebulization and transport efficiency of the CE-ICP interface was approximately 10%. Ba 2+ and Mg 2+ ions were eluted from the CE-chip within 30 s. Resolution of the Ba 2+ and Mg 2+ peaks was 0.7 using the chip-based CE-ICP-AES system. © The Royal Society of Chemistry 2006. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Royal Society of Chemistry. The Journal's web site is located at http://www.rsc.org/jaas | en_HK |
dc.relation.ispartof | Journal of Analytical Atomic Spectrometry | en_HK |
dc.title | Interface of chip-based capillary electrophoresis-inductively coupled plasma-atomic emission spectrometry (CE-ICP-AES) | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0267-9477&volume=21&spage=134&epage=140&date=2006&atitle=Interface+of+chip-based+capillary+electrophoresis-inductively+coupled+plasma-atomic+emission+spectrometry+(CE-ICP-AES) | en_HK |
dc.identifier.email | Chan, WT:wtchan@hku.hk | en_HK |
dc.identifier.authority | Chan, WT=rp00668 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1039/b509080f | en_HK |
dc.identifier.scopus | eid_2-s2.0-33645508500 | en_HK |
dc.identifier.hkuros | 123723 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-33645508500&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 21 | en_HK |
dc.identifier.issue | 2 | en_HK |
dc.identifier.spage | 134 | en_HK |
dc.identifier.epage | 140 | en_HK |
dc.identifier.eissn | 1364-5544 | - |
dc.identifier.isi | WOS:000235453200017 | - |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | Hui, AYN=36110977400 | en_HK |
dc.identifier.scopusauthorid | Wang, G=35202228100 | en_HK |
dc.identifier.scopusauthorid | Lin, B=7403508047 | en_HK |
dc.identifier.scopusauthorid | Chan, WT=7403918827 | en_HK |
dc.identifier.issnl | 0267-9477 | - |