File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Studies of matrix effects for the analysis of zinc in sodium chloride using direct sample insertion-inductively coupled plasma atomic emission spectrometry

TitleStudies of matrix effects for the analysis of zinc in sodium chloride using direct sample insertion-inductively coupled plasma atomic emission spectrometry
Authors
Issue Date2000
PublisherJapan Society for Analytical Chemistry. The Journal's web site is located at http://wwwsoc.nii.ac.jp/jsac/analsci.html
Citation
Analytical Sciences, 2000, v. 16 n. 2, p. 235-239 How to Cite?
AbstractThe matrix effects on analyte vaporization and ICP excitation conditions in direct sample insertion-inductively coupled plasma atomic emission spectrometry were studied. Zn was used as a test element and NaCl as the matrix. A slow insertion speed of the sample probe was used to allow partial separation in time of the vaporization of the volatile Zn species and the NaCl matrix. Temporal studies of the Zn emission intensity indicate that ZnCl2 starts to vaporize during sample probe insertion in the presence of the NaCl matrix. The Zn intensity is reduced because the plume of Zn vapor is not concentrated in the central channel of the ICP. Temporal profiles of the intensity ratio of ZnII/ZnI also shows that introduction of a large quantity of NaCl into the ICP has little effect on the ICP excitation conditions. The ICP is, however, significantly cooled due to heat loss to the sample probe.
Persistent Identifierhttp://hdl.handle.net/10722/69045
ISSN
2021 Impact Factor: 1.967
2020 SCImago Journal Rankings: 0.392
References

 

DC FieldValueLanguage
dc.contributor.authorChan, WTen_HK
dc.contributor.authorChan, GCYen_HK
dc.contributor.authorGong, Zen_HK
dc.contributor.authorFan, NMNen_HK
dc.date.accessioned2010-09-06T06:10:03Z-
dc.date.available2010-09-06T06:10:03Z-
dc.date.issued2000en_HK
dc.identifier.citationAnalytical Sciences, 2000, v. 16 n. 2, p. 235-239en_HK
dc.identifier.issn0910-6340en_HK
dc.identifier.urihttp://hdl.handle.net/10722/69045-
dc.description.abstractThe matrix effects on analyte vaporization and ICP excitation conditions in direct sample insertion-inductively coupled plasma atomic emission spectrometry were studied. Zn was used as a test element and NaCl as the matrix. A slow insertion speed of the sample probe was used to allow partial separation in time of the vaporization of the volatile Zn species and the NaCl matrix. Temporal studies of the Zn emission intensity indicate that ZnCl2 starts to vaporize during sample probe insertion in the presence of the NaCl matrix. The Zn intensity is reduced because the plume of Zn vapor is not concentrated in the central channel of the ICP. Temporal profiles of the intensity ratio of ZnII/ZnI also shows that introduction of a large quantity of NaCl into the ICP has little effect on the ICP excitation conditions. The ICP is, however, significantly cooled due to heat loss to the sample probe.en_HK
dc.languageengen_HK
dc.publisherJapan Society for Analytical Chemistry. The Journal's web site is located at http://wwwsoc.nii.ac.jp/jsac/analsci.htmlen_HK
dc.relation.ispartofAnalytical Sciencesen_HK
dc.titleStudies of matrix effects for the analysis of zinc in sodium chloride using direct sample insertion-inductively coupled plasma atomic emission spectrometryen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0910-6340&volume=16&spage=235&epage=239&date=2000&atitle=Studies+of+matrix+effects+for+the+analysis+of+zinc+in+sodium+chloride+using+direct+sample+insertion-inductively+coupled+plasma+atomic+emission+spectrometryen_HK
dc.identifier.emailChan, WT:wtchan@hku.hken_HK
dc.identifier.authorityChan, WT=rp00668en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-0034113641en_HK
dc.identifier.hkuros52989en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034113641&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume16en_HK
dc.identifier.issue2en_HK
dc.identifier.spage235en_HK
dc.identifier.epage239en_HK
dc.publisher.placeJapanen_HK
dc.identifier.scopusauthoridChan, WT=7403918827en_HK
dc.identifier.scopusauthoridChan, GCY=7202355292en_HK
dc.identifier.scopusauthoridGong, Z=7201949114en_HK
dc.identifier.scopusauthoridFan, NMN=7007171147en_HK
dc.identifier.issnl0910-6340-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats