Article: Ion chromatographic determination of traces of some oxoanions with direct spectrophotometric detection

TitleIon chromatographic determination of traces of some oxoanions with direct spectrophotometric detection
Authors
Keywordschromatography
metal speciation
oxoanions
waters
Issue Date1995
PublisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/aca
Citation
Analytica Chimica Acta, 1995, v. 300 n. 1-3, p. 207-214 How to Cite?
AbstractInvestigation of the use of a single analytical procedure using the non-suppressed ion chromatographic method with direct spectrophotometric detection capable of determining eight oxoanions simultaneously is presented in this paper. Potassium phosphate was found to be the most suitable eluent for UV absorbance detection at 205 nm. Oxoanions AsO3 3-, SeO3 2-, AsO4 3-, VO3 -, SeO4 2-, WO4 2-, MoO4 2- and CrO4 2- were detected at ng ml-1 levels with well separated peaks at retention time < 25 min. The working range is in the range ng ml-1 to 50 μg ml-1. The method is sufficiently sensitive to determine As(V), V(V), Mo(VI) and Cr(VI) anions (and NO3 -) directly in a river water sample. The accuracy of these results was established by comparison with conventional atomic absorption methods.
Persistent Identifierhttp://hdl.handle.net/10722/69035
ISSN
2023 Impact Factor: 5.7
2023 SCImago Journal Rankings: 0.998
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorFung, YSen_HK
dc.contributor.authorDao, KLen_HK
dc.date.accessioned2010-09-06T06:09:57Z-
dc.date.available2010-09-06T06:09:57Z-
dc.date.issued1995en_HK
dc.identifier.citationAnalytica Chimica Acta, 1995, v. 300 n. 1-3, p. 207-214en_HK
dc.identifier.issn0003-2670en_HK
dc.identifier.urihttp://hdl.handle.net/10722/69035-
dc.description.abstractInvestigation of the use of a single analytical procedure using the non-suppressed ion chromatographic method with direct spectrophotometric detection capable of determining eight oxoanions simultaneously is presented in this paper. Potassium phosphate was found to be the most suitable eluent for UV absorbance detection at 205 nm. Oxoanions AsO3 3-, SeO3 2-, AsO4 3-, VO3 -, SeO4 2-, WO4 2-, MoO4 2- and CrO4 2- were detected at ng ml-1 levels with well separated peaks at retention time < 25 min. The working range is in the range ng ml-1 to 50 μg ml-1. The method is sufficiently sensitive to determine As(V), V(V), Mo(VI) and Cr(VI) anions (and NO3 -) directly in a river water sample. The accuracy of these results was established by comparison with conventional atomic absorption methods.en_HK
dc.languageengen_HK
dc.publisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/acaen_HK
dc.relation.ispartofAnalytica Chimica Actaen_HK
dc.subjectchromatographyen_HK
dc.subjectmetal speciationen_HK
dc.subjectoxoanionsen_HK
dc.subjectwatersen_HK
dc.titleIon chromatographic determination of traces of some oxoanions with direct spectrophotometric detectionen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0003-2697&volume=300&spage=207&epage=214&date=1995&atitle=Ion+chromatographic+determination+of+traces+of+some+oxoanions+with+direct+spectrophotometric+detectionen_HK
dc.identifier.emailFung, YS:ysfung@hku.hken_HK
dc.identifier.authorityFung, YS=rp00697en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/0003-2670(94)00364-Ren_HK
dc.identifier.scopuseid_2-s2.0-0028797925en_HK
dc.identifier.hkuros1288en_HK
dc.identifier.volume300en_HK
dc.identifier.issue1-3en_HK
dc.identifier.spage207en_HK
dc.identifier.epage214en_HK
dc.identifier.isiWOS:A1995QC78100028-
dc.publisher.placeNetherlandsen_HK
dc.identifier.scopusauthoridFung, YS=13309754700en_HK
dc.identifier.scopusauthoridDao, KL=7006126314en_HK
dc.identifier.issnl0003-2670-

Export via OAI-PMH Interface in XML Formats